Added to comparison
-
Added to comparison
-
Added to comparison
YORK PHE4 packaged heat pump: 3 to 5 tons on three-phase , heating down to −23 °C
The PHE4 is a 14 SEER residential packaged unit in
Our YORK residential packaged unit that heats lowest: down to −23 °C.
Application limits from the YORK PHE4 and PH3 guides, converted from °F.
Three PHE4 units, all on 208/230 V three-phase .
The 3 in the model number, after the tonnage, means 208/230 V
- Net cooling (AHRI)
- 35,800 BTU/h14.0 SEER · 11.6 EER
- Heating at 8.3 °C
- 34,800 BTU/hCOP 3.6 · 8.0 HSPF
- Heating at −8.3 °C
- 19,800 BTU/h
- Cabinet L × W × H
- 51 1/4 × 45 3/4 × 47 in.420 lb per YORK
- Nominal airflow
- 1,150 CFM
- Outdoor sound (AHRI 270)
- 72.6 dB(A)cooling
- Circuit without backup
- 16.1 A · 20 AMCA · max. fuse or breaker
R-410A charge- 9 lb 6 oz
- Net cooling (AHRI)
- 48,000 BTU/h14.0 SEER · 11.6 EER
- Heating at 8.3 °C
- 46,500 BTU/hCOP 3.7 · 8.0 HSPF
- Heating at −8.3 °C
- 27,000 BTU/h
- Cabinet L × W × H
- 51 1/4 × 45 3/4 × 53 in.479 lb per YORK
- Nominal airflow
- 1,500 CFM
- Outdoor sound (AHRI 270)
- 72.4 dB(A)cooling
- Circuit without backup
- 20.1 A · 25 AMCA · max. fuse or breaker
R-410A charge- 14 lb 4 oz
- Net cooling (AHRI)
- 59,500 BTU/h14.0 SEER · 11.6 EER
- Heating at 8.3 °C
- 56,500 BTU/hCOP 3.6 · 8.0 HSPF
- Heating at −8.3 °C
- 33,000 BTU/h
- Cabinet L × W × H
- 51 1/4 × 45 3/4 × 55 in.485 lb per YORK
- Nominal airflow
- 1,850 CFM
- Outdoor sound (AHRI 270)
- 72.7 dB(A)cooling
- Circuit without backup
- 25.2 A · 30 AMCA · max. fuse or breaker
R-410A charge- 11 lb 10 oz
Ratings as printed by YORK under the SEER test method used before 2023: 14.0 SEER, 11.6 EER and 8.0 HSPF at all three tonnages. They do not compare directly with the PH3’s SEER2 ratings.
PHE4 or three-phase PH3, tonnage for tonnage.
Both are YORK
| Item | PHE4 | |
|---|---|---|
| Heats down to | −23 °C | −18 °C |
| Net cooling | 35,800 BTU/h | 35,400 BTU/h |
| Heating at 8.3 °C | 34,800 BTU/h | 34,000 BTU/h |
| Heating at −8.3 °C | 19,800 BTU/h | 21,000 BTU/h |
| Cabinet height | 47 in. | 47 in. |
| Weight | 420 lb | 423 lb |
| MCA without backup | 16.1 A | 21.8 A |
| Refrigerant | ||
| Published YORK warranty | 1 year parts, 5 years compressor | 1 year parts, 5 years compressor |
| Item | PHE4 | |
|---|---|---|
| Heats down to | −23 °C | −18 °C |
| Net cooling | 48,000 BTU/h | 48,500 BTU/h |
| Heating at 8.3 °C | 46,500 BTU/h | 47,000 BTU/h |
| Heating at −8.3 °C | 27,000 BTU/h | 28,600 BTU/h |
| Cabinet height | 53 in. | 50 in. |
| Weight | 479 lb | 482 lb |
| MCA without backup | 20.1 A | 24.5 A |
| Refrigerant | ||
| Published YORK warranty | 1 year parts, 5 years compressor | 1 year parts, 5 years compressor |
| Item | PHE4 | |
|---|---|---|
| Heats down to | −23 °C | −18 °C |
| Net cooling | 59,500 BTU/h | 57,500 BTU/h |
| Heating at 8.3 °C | 56,500 BTU/h | 56,000 BTU/h |
| Heating at −8.3 °C | 33,000 BTU/h | 34,200 BTU/h |
| Cabinet height | 55 in. | 55 in. |
| Weight | 485 lb | 499 lb |
| MCA without backup | 25.2 A | 29.5 A |
| Refrigerant | ||
| Published YORK warranty | 1 year parts, 5 years compressor | 1 year parts, 5 years compressor |
In green, the best value in the row. The PH3 is rated in SEER2 and the PHE4 in SEER: so we compare capacities, not ratings. See also: PH3.
The PHE4, designed by YORK, installed by AirGreen.
AirGreen confirms your
What YORK brings
- Heats down to −23 °CPublished application limit: −10 °F.
- Filters shippedFrame and washable filters inside the unit.
- ECM blowerECM motor as standard.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe check the location, access, the ducts and the electrical service.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: a
All 3 PHE4 units, right below.
One listing per tonnage, with the full YORK model number.
Shipped with its filters, ready for backup heat.
Filter frame kit and 1 in. washable filters shipped inside the unit, installed on site.
ECM blower motor as standard, per YORK’s guide.
6HK kits from 10 to 25 kW nominal, stageable above 15 kW.
PHE4B3634: what each character says.
Select a model. Only the tonnage changes between our three PHE4 units; the B means the large cabinet, the 3
- PHEPackaged heat pump, optional electric backup
- 414 SEER
- BLarge cabinet, 51 1/4 × 45 3/4 in.
- 3636,000 BTU/h nominal
- 3208/230 V
three-phase - 4Generation code (not decoded)
- PHEPackaged heat pump, optional electric backup
- 414 SEER
- BLarge cabinet, 51 1/4 × 45 3/4 in.
- 4848,000 BTU/h nominal
- 3208/230 V
three-phase - 4Generation code (not decoded)
- PHEPackaged heat pump, optional electric backup
- 414 SEER
- BLarge cabinet, 51 1/4 × 45 3/4 in.
- 6060,000 BTU/h nominal
- 3208/230 V
three-phase - 4Generation code (not decoded)
In blue, the characters that change from one listing to the next in this series. Read from the nomenclature YORK prints in the technical guide; the unit’s nameplate prevails.
The PHE4 in four numbers.
- All three of our PHE4 units need a 208/230 V
three-phase service: rare in a single-family home, more common in buildings and businesses. We check your electrical service at the visit. - For a
single-phase service, the PH3 comes in 2 to 5 tons.
None of the 3 packaged units on this page is on
What people ask us about the PHE4.
Does the PHE4 run on 240 V single-phase ?
Not ours: all three PHE4 model numbers indicate 208/230 V
How cold does the PHE4 heat?
Down to −10 °F (−23 °C) outdoors, per YORK’s application limits for our large-cabinet models. The PH3 stops at 0 °F (−18 °C).
Why 14 SEER and not SEER2?
YORK’s PHE4 guide gives ratings under the SEER test method used before 2023: 14.0 SEER, 11.6 EER and 8.0 HSPF. We don’t convert them: the conversion depends on testing.
Can the PHE4 cool in winter?
On its own, no: its low cooling limit is 55 °F (13 °C). With YORK’s
What warranty does the PHE4 carry?
YORK publishes 1 year on parts and 5 years on the compressor; exact terms are confirmed in the quote.
Your three-phase PHE4, installed by AirGreen.
At the free visit, we confirm the
Sources and dates checked
- YORK, PHE4 Technical Guide, 14 SEER,
R-410A ,three-phase 208/230 V (6078502-UTG-B-0621): features pp. 1 and 2, nomenclature p. 3, application limits p. 4, physical data p. 7, sound and electrical data p. 12; read October 27, 2026. - YORK, Technical Guide: PH3 Series, 208 V/230 V
single-phase (6677783-UTG-B-0925, September 25, 2025) andthree-phase (6803988-UTG-A-0526, May 6, 2026): warranty, features, nomenclature, application limits, physical data, sound and electrical data; read October 27, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by model number.- airgreen.ca product pages: model numbers, tonnages and power supplies of the 43 YORK packaged units we carry, read October 27, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.