YORK Sunline WN and XN rooftop units: one cabinet for 3, 4 and 5 tons
The WN (
Thirteen rooftop units, one cabinet. Everything else is in the number.
Nomenclatures of the YORK KE/WN and ZE/XN guides, page 4.
Economizer, BACnet card, leak detection: your listing, character by character.
Select a model. The 18 characters of the YORK number tell the refrigerant, tonnage, voltage and factory options.
- WPackaged heat pump,
R-454B - NStandard efficiency
- 0363 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 1208/230 V
single-phase - ANo economizer
- ARDS leak detection
- ANo optional sensors
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- WPackaged heat pump,
R-454B - NStandard efficiency
- 0363 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 2208/230 V
three-phase - ANo economizer
- ARDS leak detection
- ANo optional sensors
- CBACnet MS/TP, Modbus, N2 card
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- WPackaged heat pump,
R-454B - NStandard efficiency
- 0363 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 5575 V
three-phase - CEconomizer, no barometric relief
- ARDS leak detection
- ANo optional sensors
- CBACnet MS/TP, Modbus, N2 card
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- WPackaged heat pump,
R-454B - NStandard efficiency
- 0484 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 1208/230 V
single-phase - CEconomizer, no barometric relief
- ARDS leak detection
- ANo optional sensors
- CBACnet MS/TP, Modbus, N2 card
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- WPackaged heat pump,
R-454B - NStandard efficiency
- 0484 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 2208/230 V
three-phase - ANo economizer
- ARDS leak detection
- ANo optional sensors
- CBACnet MS/TP, Modbus, N2 card
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- WPackaged heat pump,
R-454B - NStandard efficiency
- 0484 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 5575 V
three-phase - CEconomizer, no barometric relief
- ARDS leak detection
- ANo optional sensors
- CBACnet MS/TP, Modbus, N2 card
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- WPackaged heat pump,
R-454B - NStandard efficiency
- 0605 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 1208/230 V
single-phase - ANo economizer
- ARDS leak detection
- ANo optional sensors
- CBACnet MS/TP, Modbus, N2 card
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- WPackaged heat pump,
R-454B - NStandard efficiency
- 0605 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 2208/230 V
three-phase - ANo economizer
- ARDS leak detection
- ANo optional sensors
- CBACnet MS/TP, Modbus, N2 card
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- WPackaged heat pump,
R-454B - NStandard efficiency
- 0605 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 5575 V
three-phase - CEconomizer, no barometric relief
- ARDS leak detection
- ANo optional sensors
- CBACnet MS/TP, Modbus, N2 card
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- XPackaged heat pump,
R-410A - NStandard efficiency
- 0484 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 2208/230 V
three-phase - CEconomizer, no barometric relief
- 1No service options
- ANo optional sensors
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 2Second generation
- XPackaged heat pump,
R-410A - NStandard efficiency
- 0484 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 5575 V
three-phase - CEconomizer, no barometric relief
- 1No service options
- ANo optional sensors
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 2Second generation
- XPackaged heat pump,
R-410A - NStandard efficiency
- 0605 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 2208/230 V
three-phase - CEconomizer, no barometric relief
- 1No service options
- ANo optional sensors
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 2Second generation
- XPackaged heat pump,
R-410A - NStandard efficiency
- 0605 nominal tons
- C00No factory backup heat (C00)
- BStandard static blower
- 5575 V
three-phase - CEconomizer, no barometric relief
- 1No service options
- ANo optional sensors
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 2Second generation
In blue, the characters that change from one listing to the next in this series. Read from the nomenclature YORK prints in the technical guide; the unit’s nameplate prevails.
WN or XN: same cabinet, two refrigerants.
Size for size, the XN heats a little less at −8.3 °C; at 5 tons it is quieter (80 vs. 88 dB(A)) and its compressor has two speeds. The numbers:
| Item | WN048 | XN048 |
|---|---|---|
| Refrigerant | ||
| Seasonal rating | 13.4 SEER2 | 14.0 SEER |
| Full-load efficiency | 11.2 EER2 | 11.8 EER |
| Net cooling | 47,000 BTU/h | 47,000 BTU/h |
| Heating at 8.3 °C | 44,000 BTU/h | 44,000 BTU/h |
| COP at 8.3 °C | 3.00 | 3.20 |
| Heating at −8.3 °C | 26,000 BTU/h | 24,900 BTU/h |
| COP at −8.3 °C | 2.05 | 2.10 |
| Scroll compressor | single speed | single speed |
| Outdoor sound (AHRI 270) | not published | 80 dB(A) |
| RDS leak detection | yes, on our 9 WN | none ( |
| Item | WN060 | XN060 |
|---|---|---|
| Refrigerant | ||
| Seasonal rating | 13.4 SEER2 | 14.0 SEER |
| Full-load efficiency | 10.2 EER2 | 11.0 EER |
| Net cooling | 56,000 BTU/h | 55,400 BTU/h |
| Heating at 8.3 °C | 52,000 BTU/h | 51,500 BTU/h |
| COP at 8.3 °C | 3.35 | 3.35 |
| Heating at −8.3 °C | 31,800 BTU/h | 30,000 BTU/h |
| COP at −8.3 °C | 2.20 | 2.14 |
| Scroll compressor | single speed | two-speed |
| Outdoor sound (AHRI 270) | 88 dB(A) | 80 dB(A) |
| RDS leak detection | yes, on our 9 WN | none ( |
In green, the best value in the row. SEER2 and SEER don’t compare: we compare capacities and COPs, measured at the same temperatures. Our XN listings cover 4 and 5 tons; our WN listings, 3, 4 and 5 tons. The WN guide publishes no sound level for the 4-ton.
YORK builds the Sunline; AirGreen puts it on the roof.
AirGreen reads your electrical service, picks the WN or XN and its options, then installs the unit on its roof curb and connects it to the ducts.
What YORK brings
- Smart EquipmentStandard; LCD screen and USB port on the WN.
- One cabinet for every sizeSame cabinet from 3 to 5 tons, WN and XN.
- AMCA 511 economizersClass 1A dampers, up to 100% outdoor air.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe check the location, access, the ducts and the electrical service.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: the right Sunline, with the right options, on your roof.
All 13 Sunline units, right below.
One listing per model and power supply; the decoder above reads each number.
The Smart Equipment board, standard on all 13 of our Sunline units.
YORK installs it at the factory on every WN and XN heat pump; the details below come from the WN guide.
Data logging, faults and software updates through the USB port.
Built-in screen with joystick, to read and set the board on the roof.
The pressure switches and freezestats must trip three times within two hours before the board locks out the compressor.
The board keeps the five most recent alarms for diagnosis.
BACnet MS/TP, Modbus and N2 communication to a building automation system (code C in the 14th character).
According to YORK, the WN and XN cool down to 0 °F (−18 °C); on the WN, thanks to the built-in low-ambient control. Useful for spaces that make their own heat.
Thirteen listings, thirteen circuits.
From 8 A on 575 V to 50.8 A on
| Model | Power supply | MCA | Max. fuse or breaker |
|---|---|---|---|
| WN036C00B1AAAAA1A1 | 208/230 V | 26.3 A | 35 A |
| WN036C00B2AAACA1A1 | 208/230 V | 20.8 A | 30 A |
| WN036C00B5CAACA1A1 | 575 V | 8 A | 15 A |
| WN048C00B1CAACA1A1 | 208/230 V | 37.5 A | 50 A |
| WN048C00B2AAACA1A1 | 208/230 V | 23.1 A | 30 A |
| WN048C00B5CAACA1A1 | 575 V | 10.3 A | 15 A |
| WN060C00B1AAACA1A1 | 208/230 V | 50.8 A | 70 A |
| WN060C00B2AAACA1A1 | 208/230 V | 29.1 A | 40 A |
| WN060C00B5CAACA1A1 | 575 V | 11.9 A | 15 A |
| XN048C00B2C1AAA1A2 | 208/230 V | 24.2 A | 30 A |
| XN048C00B5C1AAA1A2 | 575 V | 9 A | 15 A |
| XN060C00B2C1AAA1A2 | 208/230 V | 27.7 A | 35 A |
| XN060C00B5C1AAA1A2 | 575 V | 9.9 A | 15 A |
Values from the electrical tables of the YORK guide, without electric heat or a powered convenience outlet. Field-added electric heat changes the calculation; the unit’s nameplate prevails. Standard static blower, as on all 13 of our listings. Allowed applied voltage: 187 to 252 V on 208/230 V, 540 to 630 V on 575 V.
Four numbers for placing a Sunline.
- The economizer’s power exhaust is for bottom duct connections only, according to YORK.
- The coil guard offered as an accessory is not a hail guard: YORK sells the hail guard separately.
None of the 13 packaged units on this page is on
What people ask us about the Sunline.
Why “Sunline” when the guide says KE/WN?
YORK’s WN guide is titled “KE/WN Series”, the XN guide “ZE/XN Series”. We keep the Sunline name for the family, and the WN and XN numbers for each listing.
Which listings have an economizer?
Eight of thirteen: the WN036, WN048 and WN060 on 575 V, the
Can the WN connect to a building automation system?
Yes for eight of our nine WN, which have the BACnet MS/TP, Modbus and N2 card (code C in the 14th character). The
Does the Sunline heat in deep cold?
YORK’s guide publishes no heating limit for these rooftop units; it gives capacity at 17 °F (−8.3 °C): 21,000 to 31,800 BTU/h for the WN. Electric heat (5 to 30 kW on the WN) is sized at the visit.
What YORK warranty does the Sunline carry?
Per the guides: 1 year on the complete unit, 5 years on the compressor and on factory-installed heater elements.
Your Sunline, on your roof, installed by AirGreen.
At the free visit, we read the electrical service, check the roof curb and ducts, and the quote gives the full model number.
Sources and dates checked
- YORK, KE/WN Series Technical Guide, 3 to 6 tons,
R-454B (6481655-YTG-B-1124): nomenclature p. 4, features pp. 5 to 9, physical data pp. 14 to 16, sound p. 43, electrical data pp. 64 to 66; read October 27, 2026. - YORK, ZE/XN Series Technical Guide, 3 to 6 tons,
R-410A (5190086-YTG-G-1119): nomenclature p. 4, features pp. 5 to 7, physical data pp. 14 to 16, sound p. 45, electrical data pp. 52 to 54; read October 27, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by model number.- airgreen.ca product pages: model numbers, tonnages and power supplies of the 43 YORK packaged units we carry, read October 27, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.