YORK Sun Pro rooftop unit: two compressors, 7.5 to 12.5 tons
The Sun Pro has two compressors on two independent circuits: 50% capacity with one, 100% with both. WP in
Two compressors, two circuits: at half load, half the system runs.
YORK Sun Pro WP and XP technical guides, description and physical data.
Five Sun Pro models, 92,000 to 141,000 BTU/h net.
Select a model: ratings, heating capacities, cabinet and the circuit of each listing.
- Net cooling (AHRI)
- 96,000 BTU/h12.2 EER · 16.0 IEER
- Heating at 8.3 °C
- 87,000 BTU/hCOP 3.5
- Heating at −8.3 °C
- 51,000 BTU/hCOP 2.25
- Cabinet L × W × H
- 89 × 59 × 50 3/4 in.1,090 lb per YORK
- Nominal airflow
- 3,000 CFM
- Outdoor sound (AHRI 270)
- 83 dB(A)
- Compressors
- 2 scroll50% and 100% stages
- Charge, circuits 1 + 2
- 12 lb + 12 lb
- Circuit (MCA · max. fuse)
- 3-ph: 43.8 A · 50 Ahigh-static blower, no backup heat
- Net cooling (AHRI)
- 116,000 BTU/h11.2 EER · 15.2 IEER
- Heating at 8.3 °C
- 104,000 BTU/hCOP 3.5
- Heating at −8.3 °C
- 60,000 BTU/hCOP 2.25
- Cabinet L × W × H
- 89 × 59 × 50 3/4 in.1,135 lb per YORK
- Nominal airflow
- 3,300 CFM
- Outdoor sound (AHRI 270)
- 83 dB(A)
- Compressors
- 2 scroll50% and 100% stages
- Charge, circuits 1 + 2
- 12 lb + 11 lb 4 oz
- Circuit (MCA · max. fuse)
- 3-ph: 52.5 A · 60 Ahigh-static blower, no backup heat
- Net cooling (AHRI)
- 92,000 BTU/h11.2 EER · 14.6 IEER
- Heating at 8.3 °C
- 87,000 BTU/hCOP 3.5
- Heating at −8.3 °C
- 51,000 BTU/hCOP 2.25
- Cabinet L × W × H
- 89 × 59 × 50 3/4 in.1,090 lb per YORK
- Nominal airflow
- 3,000 CFM
- Outdoor sound (AHRI 270)
- 83 dB(A)
- Compressors
- 2 scroll50% and 100% stages
- Charge, circuits 1 + 2
- 13 lb + 13 lb 2 oz
- Circuit (MCA · max. fuse)
- 3-ph: 43.7 A · 50 A · 575 V: 15.7 A · 20 Ahigh-static blower, no backup heat
- Net cooling (AHRI)
- 111,000 BTU/h11.0 EER · 14.5 IEER
- Heating at 8.3 °C
- 102,000 BTU/hCOP 3.5
- Heating at −8.3 °C
- 59,000 BTU/hCOP 2.25
- Cabinet L × W × H
- 89 × 59 × 50 3/4 in.1,135 lb per YORK
- Nominal airflow
- 3,300 CFM
- Outdoor sound (AHRI 270)
- 83 dB(A)
- Compressors
- 2 scroll50% and 100% stages
- Charge, circuits 1 + 2
- 12 lb 14 oz + 12 lb 12 oz
- Circuit (MCA · max. fuse)
- 3-ph: 47.6 A · 60 A · 575 V: 18.4 A · 20 Ahigh-static blower, no backup heat
- Net cooling (AHRI)
- 141,000 BTU/h10.6 EER · 14.5 IEER
- Heating at 8.3 °C
- 138,000 BTU/hCOP 3.3
- Heating at −8.3 °C
- 82,000 BTU/hCOP 2.15
- Cabinet L × W × H
- 119 7/16 × 59 × 50 3/4 in.1,403 lb per YORK
- Nominal airflow
- 4,600 CFM
- Outdoor sound (AHRI 270)
- 84 dB(A)
- Compressors
- 2 scroll50% and 100% stages
- Charge, circuits 1 + 2
- 17 lb 2 oz + 15 lb 8 oz
- Circuit (MCA · max. fuse)
- 3-ph: 78.4 A · 100 Ahigh-static blower, no backup heat
Full-load EER and weighted IEER, as printed by YORK. Heating rated at 47 °F (8.3 °C) and 17 °F (−8.3 °C).
WP or XP, tonnage for tonnage.
The
| Item | WP090 | XP090 |
|---|---|---|
| Refrigerant | ||
| IEER | 16.0 | 14.6 |
| EER | 12.2 | 11.2 |
| Net cooling | 96,000 BTU/h | 92,000 BTU/h |
| Heating at 8.3 °C | 87,000 BTU/h | 87,000 BTU/h |
| Heating at −8.3 °C | 51,000 BTU/h | 51,000 BTU/h |
| Weight | 1,090 lb | 1,090 lb |
| RDS leak detection | yes | none ( |
| Item | WP120 | XP120 |
|---|---|---|
| Refrigerant | ||
| IEER | 15.2 | 14.5 |
| EER | 11.2 | 11.0 |
| Net cooling | 116,000 BTU/h | 111,000 BTU/h |
| Heating at 8.3 °C | 104,000 BTU/h | 102,000 BTU/h |
| Heating at −8.3 °C | 60,000 BTU/h | 59,000 BTU/h |
| Weight | 1,135 lb | 1,135 lb |
| RDS leak detection | yes | none ( |
In green, the best value in the row. Same 89 × 59 × 50 3/4 in. cabinet for both. Our 12.5-ton listing is the XP150.
YORK builds the Sun Pro; AirGreen plans the roof.
AirGreen checks the electrical service and roof access, has the roof’s load capacity confirmed when needed, picks the WP or XP, then installs and connects the unit.
What YORK brings
- Two independent circuitsTwo scroll compressors, 50% then 100%.
- IntelliSpeedVFD blower on all seven of our listings.
- Tool-free panelsHinged access to the usual components.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe check the location, access, the ducts and the electrical service.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: the right Sun Pro, lifted and connected on your roof.
All 7 Sun Pro units, right below.
One listing per model and power supply, with the full YORK model number.
Designed for the technician who climbs on the roof.
YORK says it is designed for easy service. In practice:
Tool-free for routine service; screwed shut at the factory to keep children out.
In both condenser walls, to inspect the coils.
Non-corrosive composite pan that slides out for cleaning.
Inside the control access door.
24 × 20 × 2 in. on every size.
The board can alternate which compressor starts, to even out run hours.
Barometric economizer, phase monitor, BACnet card: each listing, decoded.
Select a model. All seven have the IntelliSpeed variable-frequency blower, high static (code R).
- WPackaged heat pump,
R-454B - PStandard efficiency
- 0907.5 nominal tons
- C00No factory backup heat (C00)
- RIntelliSpeed VFD, high static
- 2208/230 V
three-phase - BEconomizer with barometric relief
- ARDS leak detection
- BPhase monitor
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- WPackaged heat pump,
R-454B - PStandard efficiency
- 12010 nominal tons
- C00No factory backup heat (C00)
- RIntelliSpeed VFD, high static
- 2208/230 V
three-phase - ANo economizer
- ARDS leak detection
- ANo optional sensors
- CBACnet MS/TP, Modbus, N2 card
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 1First generation
- XPackaged heat pump,
R-410A - PStandard efficiency
- 0907.5 nominal tons
- C00No factory backup heat (C00)
- RIntelliSpeed VFD, high static
- 2208/230 V
three-phase - BEconomizer with barometric relief
- 1No service options
- BPhase monitor
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 2Second generation
- XPackaged heat pump,
R-410A - PStandard efficiency
- 0907.5 nominal tons
- C00No factory backup heat (C00)
- RIntelliSpeed VFD, high static
- 5575 V
three-phase - BEconomizer with barometric relief
- 1No service options
- BPhase monitor
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 2Second generation
- XPackaged heat pump,
R-410A - PStandard efficiency
- 12010 nominal tons
- C00No factory backup heat (C00)
- RIntelliSpeed VFD, high static
- 2208/230 V
three-phase - ANo economizer
- 1No service options
- ANo optional sensors
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 2Second generation
- XPackaged heat pump,
R-410A - PStandard efficiency
- 12010 nominal tons
- C00No factory backup heat (C00)
- RIntelliSpeed VFD, high static
- 5575 V
three-phase - BEconomizer with barometric relief
- 1No service options
- BPhase monitor
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 2Second generation
- XPackaged heat pump,
R-410A - PStandard efficiency
- 15012.5 nominal tons
- C00No factory backup heat (C00)
- RIntelliSpeed VFD, high static
- 2208/230 V
three-phase - BEconomizer with barometric relief
- 1No service options
- BPhase monitor
- AStand-alone Smart Equipment control
- AStandard coils, no E-Coat
- 1Standard throwaway filter
- AStandard cabinet
- 3Third generation
In blue, the characters that change from one listing to the next in this series. Read from the nomenclature YORK prints in the technical guide; the unit’s nameplate prevails.
Seven listings, seven circuits.
With power exhaust, the guide adds 1.8 to 5.5 A to the MCA depending on voltage.
| Model | Power supply | MCA | Max. fuse or breaker |
|---|---|---|---|
| WP090C00R2BABAA1A1 | 208/230 V | 43.8 A | 50 A |
| WP120C00R2AAACA1A1 | 208/230 V | 52.5 A | 60 A |
| XP090C00R2B1BAA1A2 | 208/230 V | 43.7 A | 50 A |
| XP090C00R5B1BAA1A2 | 575 V | 15.7 A | 20 A |
| XP120C00R2A1AAA1A2 | 208/230 V | 47.6 A | 60 A |
| XP120C00R5B1BAA1A2 | 575 V | 18.4 A | 20 A |
| XP150C00R2B1BAA1A3 | 208/230 V | 78.4 A | 100 A |
Values from the electrical tables of the YORK guide, without electric heat or a powered convenience outlet. Field-added electric heat changes the calculation; the unit’s nameplate prevails. The guide’s “Hi-Static motor” table, used for the high-static blower (code R) of our seven listings.
The Sun Pro in four numbers.
- Crankcase heaters are standard on WP and XP compressors, per the guides.
- Published YORK warranty: 1 year on the complete unit, 5 years on the compressors and on factory-installed heater elements.
None of the 7 packaged units on this page is on
What people ask us about the Sun Pro.
What are two compressors for?
To run at 50% capacity at light load, instead of cycling the whole unit. The two circuits are independent: each has its compressor, its pressure switches and its refrigerant charge.
Why IEER and not SEER2?
Above 65,000 BTU/h, commercial units are rated in EER (full load) and IEER, which weights part load. SEER2 doesn’t apply at these tonnages.
What’s the difference between the WP and the XP?
The refrigerant,
Is a crane needed?
At 1,090 to 1,403 lb per YORK’s guides, often. A forklift can reach the cabinet from three sides. We plan the lift at the visit.
What blower do your Sun Pro units have?
All seven have the IntelliSpeed variable-frequency blower, high static (code R); YORK describes it as a multi-speed supply fan.
Your Sun Pro, on your roof, installed by AirGreen.
At the free visit, we check the electrical service and roof access; when needed, an engineer confirms the load capacity, and the quote gives the exact model.
Sources and dates checked
- YORK, Technical Guide: Sun Pro WP Series, 6.5 to 12.5 tons,
R-454B (6481341-YTG-B-0125, January 17, 2025): description p. 5, nomenclature p. 7, features pp. 8 to 11, physical data pp. 22 and 23, sound p. 43, electrical data pp. 46 and 47; read October 27, 2026. - YORK, XP Series Technical Guide, Sun Pro, 6.5 to 12.5 tons,
R-410A (5167824-YTG-P-0323): nomenclature p. 3, features pp. 4 to 6, physical data pp. 12 and 13, sound p. 34, electrical data pp. 37 and 38; read October 27, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by model number.- airgreen.ca product pages: model numbers, tonnages and power supplies of the 43 YORK packaged units we carry, read October 27, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.