YORK Sun Core rooftop unit: 3 to 10 tons, on two cabinets
The Sun Core covers 3 to 10 tons on two cabinets, in three efficiency tiers: XQ, XX and XY. YORK designed the X models’ rails to fit many roof curbs already in place. 13 listings: 7 in
Two footprints, 3 to 10 tons and, on the X models, base rails designed for curbs already in place.
YORK XYE/XXE/XQE technical guide, physical data; WQE and WYE listings.
XQ, XX, XY: the first two letters tell the tier.
YORK names the series by its letters. The X models use
“14 SEER”, standard efficiency, 3 to 5 tons: one compressor, one circuit. SEER2 and HSPF2 (6.7) ratings.
4 listings · 3 to 5 tStandard efficiency; our 7.5- and 10-ton XXE08 and XXE12 have the IntelliSpeed VFD; the guide lists two compressors on the XXE08.
2 listings · 7.5 and 10 tHigh efficiency. Our 6-ton XYEA7 has a
WQE and WYE, in
35,600 to 115,000 BTU/h net, on seven listings.
Models from 3 to 5 tons are rated in SEER2; those of 6 tons and up, in IEER. Select the voltage under the model to open its listing.
| Model | Tons | Net cooling | Rating | Heating at 8.3 °C | Heating at −8.3 °C | Cabinet (in.) | Weight | Outdoor sound |
|---|---|---|---|---|---|---|---|---|
| XQE043-ph | 3 | 35,600 BTU/h | 13.4 SEER2 · 12.0 EER2 · 6.7 HSPF2 | 34,200 BTU/hCOP 3.25 | 18,500 BTU/hCOP 2.12 | 74.1 × 48.9 × 32.5 | 529 lb | 78.4 dB(A) |
| XQE053-ph | 4 | 48,000 BTU/h | 13.4 SEER2 · 12.0 EER2 · 6.7 HSPF2 | 46,700 BTU/hCOP 3.50 | 26,400 BTU/hCOP 2.00 | 74.1 × 48.9 × 40.6 | 554 lb | 78.4 dB(A) |
| XQE063-ph 575 V | 5 | 57,400 BTU/h | 13.4 SEER2 · 11.9 EER2 · 6.7 HSPF2 | 53,000 BTU/hCOP 3.50 | 29,000 BTU/hCOP 2.20 | 74.1 × 48.9 × 40.6 | 627 lb | 77.8 dB(A) |
| XYEA73-ph | 6 | 70,000 BTU/h | 16.5 IEER · 12.0 EER | 67,000 BTU/hCOP 3.40 | 38,000 BTU/hCOP 2.40 | 87.2 × 61.7 × 40.6 | 895 lb | 83.0 dB(A) |
| XXE08575 V | 7.5 | 90,000 BTU/h | 15.1 IEER · 11.5 EER | 84,000 BTU/hCOP 3.50 | 49,000 BTU/hCOP 2.25 | 87.2 × 61.7 × 48.6 | 976 lb | 83.2 dB(A) |
| XXE12575 V | 10 | 115,000 BTU/h | 14.6 IEER · 11.0 EER | 114,000 BTU/hCOP 3.40 | 62,000 BTU/h | 87.2 × 61.7 × 48.6 | 1,060 lb | 86.0 dB(A) |
Values from the YORK guide’s AHRI table and physical data. The XXE12’s COP at −8.3 °C is not shown: the power printed beside it doesn’t match the capacity.
WQE and WYE: R-454B on the small cabinet.
| Model | Tons | Seasonal rating (listing) | Heating rating (listing) | Cabinet (in.) | Listings |
|---|---|---|---|---|---|
| WQE04 | 3 | 14.0 | 6.7 | 74.1 × 48.9 × 32.5 | 3-ph |
| WQE05 | 4 | 14.0 | 6.7 | 74.1 × 48.9 × 40.6 | 1-ph 3-ph |
| WQE06 | 5 | 14.0 | 6.7 | 74.1 × 48.9 × 40.6 | 3-ph 575 V |
| WYE06 | 5 | 14.3 | 6.9 | 74.1 × 48.9 × 40.6 | 3-ph |
- No YORK technical guide for the WQE and WYE models could be found on October 27, 2026: we publish no capacity, sound or circuit for them. We confirm them on YORK’s submittal before ordering.
- Their number doesn’t exactly follow the X models’ nomenclature: we don’t decode it.
YORK builds the Sun Core; AirGreen installs it on your curb.
AirGreen measures the existing roof curb, reads the electrical service, picks the tier and tonnage, then installs and connects the unit.
What YORK brings
- Built for existing roofsX-model base rails designed to fit many curbs already in place.
- Three tiersXQ, XX and XY, 3 to 10 tons.
- Embossed topStiffer cabinet; paint tested 750 h in salt spray.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe check the location, access, the ducts and the electrical service.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: the right Sun Core, set on your roof curb.
All 13 Sun Core units, right below.
One listing per model and power supply, X and W models.
What YORK builds into the Sun Core cabinet.
According to YORK, the X models’ perimeter base rails are designed to fit many roof curbs already in place.
The top panel is embossed to stiffen the cabinet; paint tested 750 hours in salt spray.
2 in. MERV 4 filters standard; switch to MERV 8 or 13 through the tool-free filter door.
Cooling tested and rated up to 125 °F (52 °C) outdoor air.
According to YORK’s guide, cooling goes down to 40 °F (4 °C) outdoor air, with the low-ambient control.
Epoxy-coated coil option: YORK adds a 3-year warranty when it’s selected. None of our X models has it.
Dry-bulb or enthalpy economizer, blower, VFD: each X model, decoded.
Select a model. The Sun Core follows its own nomenclature: 18 characters, in a different order from the Sunline and Sun Pro.
- XQPackaged heat pump, 14 SEER standard efficiency
- EElectric heat added on site
- 043 tons
- ANo factory heat
- 2208/230 V
three-phase - BBelt-drive blower, medium static
- 1No VFD
- AStandard coils, no E-Coat
- ASmart Equipment control
- 1No smoke detector
- ANo economizer
- 1No convenience outlet
- 1No factory disconnect
- 1Standard cabinet
- ANo special option
- 2Second generation
- XQPackaged heat pump, 14 SEER standard efficiency
- EElectric heat added on site
- 054 tons
- ANo factory heat
- 2208/230 V
three-phase - CBelt-drive blower, high static
- 1No VFD
- AStandard coils, no E-Coat
- ASmart Equipment control
- 1No smoke detector
- BDry-bulb economizer
- 1No convenience outlet
- 1No factory disconnect
- 1Standard cabinet
- ANo special option
- 3Generation code newer than the guide we read
- XQPackaged heat pump, 14 SEER standard efficiency
- EElectric heat added on site
- 065 tons
- ANo factory heat
- 2208/230 V
three-phase - BBelt-drive blower, medium static
- 1No VFD
- AStandard coils, no E-Coat
- ASmart Equipment control
- 1No smoke detector
- ANo economizer
- 1No convenience outlet
- 1No factory disconnect
- 1Standard cabinet
- ANo special option
- 3Generation code newer than the guide we read
- XQPackaged heat pump, 14 SEER standard efficiency
- EElectric heat added on site
- 065 tons
- ANo factory heat
- 5575 V
three-phase - CBelt-drive blower, high static
- 1No VFD
- AStandard coils, no E-Coat
- ASmart Equipment control
- 1No smoke detector
- BDry-bulb economizer
- 1No convenience outlet
- 1No factory disconnect
- 1Standard cabinet
- ANo special option
- 3Generation code newer than the guide we read
- XYPackaged heat pump, high efficiency
- EElectric heat added on site
- A76 tons,
two-stage - ANo factory heat
- 2208/230 V
three-phase - BBelt-drive blower, medium static
- 3IntelliSpeed VFD
- AStandard coils, no E-Coat
- ASmart Equipment control
- 1No smoke detector
- CEnthalpy economizer
- 1No convenience outlet
- 1No factory disconnect
- 1Standard cabinet
- ANo special option
- 2Second generation
- XXPackaged heat pump, standard efficiency
- EElectric heat added on site
- 087.5 tons
- ANo factory heat
- 5575 V
three-phase - BBelt-drive blower, medium static
- 3IntelliSpeed VFD
- AStandard coils, no E-Coat
- ASmart Equipment control
- 1No smoke detector
- BDry-bulb economizer
- 1No convenience outlet
- 1No factory disconnect
- 1Standard cabinet
- ANo special option
- 2Second generation
- XXPackaged heat pump, standard efficiency
- EElectric heat added on site
- 1210 tons
- ANo factory heat
- 5575 V
three-phase - CBelt-drive blower, high static
- 3IntelliSpeed VFD
- AStandard coils, no E-Coat
- ASmart Equipment control
- 1No smoke detector
- BDry-bulb economizer
- 1No convenience outlet
- 1No factory disconnect
- 1Standard cabinet
- ANo special option
- 3Generation code newer than the guide we read
In blue, the characters that change from one listing to the next in this series. Read from the nomenclature YORK prints in the technical guide; the unit’s nameplate prevails.
The Sun Core in four numbers.
- Electric heat is field-installed only: the E in the number says so.
- The high-static blower (code C) is
three-phase only, according to YORK.
None of the 13 packaged units on this page is on
What people ask us about the Sun Core.
Will the Sun Core fit my existing roof curb?
Often, according to YORK: the X models’ perimeter base rails are designed to fit many curbs already in place. We measure yours at the visit before confirming.
What’s the difference between XQ, XX and XY?
The efficiency tier: XQ, “14 SEER” standard from 3 to 5 tons; XX, standard efficiency; XY, high efficiency. Our 6-ton XYEA7 reaches 16.5 IEER.
Does the Sun Core cool in winter?
Down to 40 °F (4 °C) outdoor air, per YORK’s guide, with the low-ambient control. The Sunline and Sun Pro go to 0 °F (−18 °C): for a space that makes its own heat all year, we discuss it at the visit.
Which listings have an economizer?
Five of the seven X listings: dry-bulb on the XQE05, the 575 V XQE06, XXE08 and XXE12, and enthalpy on the XYEA7. The 13th character of the number shows it.
Why so little data on the WQE and WYE?
Because we found no YORK technical guide for these models on October 27, 2026. We publish only our listings’ ratings and confirm the rest on YORK’s submittal.
Your Sun Core, on your roof curb, installed by AirGreen.
At the free visit, we measure the existing curb, read the electrical service, and the quote gives the exact model.
Sources and dates checked
- YORK, XYE/XXE/XQE Series Technical Guide, 3 to 10 tons (5147362-YTG-R-0323): features pp. 4 to 8, nomenclature p. 9, AHRI table and sound p. 12, physical data pp. 13 to 19; read October 27, 2026.
- airgreen.ca product pages of the WQE and WYE models: SEER and HSPF ratings (rating edition not stated) and dimensions, read October 27, 2026 (no YORK technical guide for these models found at that date).
Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by model number.- airgreen.ca product pages: model numbers, tonnages and power supplies of the 43 YORK packaged units we carry, read October 27, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.