AirGreenYORK
YORK · PH3 packaged unit YORK at AirGreenSold and installed by AirGreen in Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full YORK range
AirGreen × YORKSold and installed by AirGreenPH3, R-454B2 to 5 tonsSingle- or three-phaseTop dischargeMontreal · Laval · Longueuil · South Shore · North Shore
01 · Tonnage by tonnage

Four PH3 units, 24,000 to 60,000 BTU/h.

Select a tonnage: ratings, cabinet, sound and both possible circuits.

Tonnage
PH3E36N0036,000 BTU/h · 3 tons
PH3E36N00S21 · PH3E36N00S31
Net cooling (AHRI)
35,400 BTU/h13.4 SEER2 · 11.1 EER2
Heating at 8.3 °C
34,000 BTU/hCOP 3.6 · HSPF2 6.7
Heating at −8.3 °C
21,000 BTU/h
Cabinet L × W × H
51 1/4 × 45 3/4 × 47 in.423 lb per YORK
Nominal airflow
1,200 CFM
Outdoor sound (AHRI 270)
72.9 dB(A)single-phase, cooling; three-phase: 72 dB(A)
Single-phase circuit
27.3 A · 40 AMCA · max. protection, no backup heat
Three-phase circuit
21.8 A · 30 AMCA · max. protection, no backup heat
R-454B charge
7 lb 5 oz
Outdoor range
heats down to −18 °Ccools from 13 to 52 °C

AHRI ratings as printed by YORK: 13.4 SEER2, 11.1 EER2 and 6.7 HSPF2 at all four tonnages. Heating rated at 47 °F (8.3 °C) and 17 °F (−8.3 °C). Performance is the same on single- and three-phase; the circuit and the warranty change.

02 · Single- or three-phase

The same PH3, not the same warranty.

Ratings and cabinet don’t change from one power supply to the other. The warranty YORK publishes changes completely.

Single-phase 208/230 V

Extended YORK warranty of 10 years on parts and compressor, with online registration within 90 days of installation. Offered from 2 to 5 tons. Electric backup from 5 to 25 kW nominal.

4 listings · code S21
Three-phase 208/230 V

Standard YORK warranty: 1 year on parts, 5 years on the compressor. Offered from 3 to 5 tons. Smaller circuit (MCA 21.8 to 29.5 A), filter frame and filters shipped with the unit. Backup from 10 to 25 kW.

3 listings · code S31
  • Exact terms are confirmed in the quote; each version’s technical guide summarizes them this way.
  • The power supply is in the model number: the 11th character is 2 for single-phase and 3 for three-phase.
AirGreen × YORK

The PH3, designed by YORK, installed by AirGreen.

AirGreen checks your electrical service, picks the tonnage and version, then installs the PH3 on its pad or roof curb and connects it to your ducts.

YORK

What YORK brings

  • 13.4 SEER2, R-454BAt all four tonnages, with factory leak detection.
  • Two footprints35 3/4 in. wide at 2 tons, 45 3/4 in. from 3 to 5 tons.
  • Removable base railsForklift from every side; two screws per corner.
AirGreen

What AirGreen brings

  • Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
  • Free visitWe check the location, access, the ducts and the electrical service.
  • Clear quoteThe exact model, what is included and the price, in writing.
  • RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.

The result: the right PH3 for your home, installed by AirGreen.

The YORK shop · PH3

All 7 PH3 units, right below.

One listing per tonnage and power supply; the model number says single-phase (S21) or three-phase (S31).

YORK
03 · Construction

What YORK builds into the PH3 cabinet.

Top discharge

The fan blows upward, above the cabinet.

G90 steel

G90 galvanized steel and powder coat, tested 1,000 hours in salt spray.

Removable base rails

Forklift access from every side; two screws per corner to remove them when height is short.

Factory RDS

R-454B leak detection installed at the factory; the thermostat wires to its screw terminals.

Demand defrost

Defrost curves preloaded in the board, matched to the unit’s capacity.

Stamped coil grille

Slotted, it protects the outdoor coil.

04 · The model number, read for you

Twelve characters, and the eleventh decides the warranty.

Select a model. The 2 or 3 in second-to-last position tells single- or three-phase.

Model
  1. PHPackaged heat pump, optional electric heat
  2. 313.4 SEER2
  3. ER-454B refrigerant
  4. 2424,000 BTU/h nominal
  5. N00Electric type, no factory kit (N00): 6HK backup added on site if needed
  6. SStandard conventional control
  7. 2208/230 V single-phase
  8. 1First generation

See this model’s page →

In blue, the characters that change from one listing to the next in this series. Read from the nomenclature YORK prints in the technical guide; the unit’s nameplate prevails.

05 · Before you choose

The PH3’s limits, in numbers.

−18 °Cpublished heating limit (0 °F) for all seven PH3 units; below that, we plan for electric backup.
13 °Cminimum outdoor temperature in cooling (55 °F).
5 to 25 kW6HK electric heat kits on single-phase; 10 to 25 kW on three-phase.
19.8 to 40 AMCA of the single-phase PH3 units without backup, by tonnage; 21.8 to 29.5 A on three-phase.
  • A field-supplied, field-installed electrical disconnect switch is mandatory, according to YORK.
  • Side-to-bottom duct conversion without cutting: the two bottom panels move onto the side openings.
0/7

None of the 7 packaged units on this page is on Hydro-Québec’s LogisVert list of October 26, 2026 (“homeowner, existing house” profile, searched by model number). So we promise no LogisVert amount on these units.

Frequently asked questions

What people ask us about the PH3.

Does the PH3 come in 2 tons?

Yes, and it’s the only 2-ton packaged unit in our catalogue: the PH3E24N00S21, on 208/230 V single-phase, on a narrower 35 3/4 in. cabinet.

Why does the warranty differ between single- and three-phase?

That’s what YORK publishes: 10 years on parts and compressor with online registration within 90 days for the single-phase version, and 1 year on parts, 5 years on the compressor for the three-phase version.

How cold does the PH3 heat?

Down to 0 °F (−18 °C) outdoors, per YORK’s application limits. Below that, the electric backup takes over; we size it at the visit.

What circuit does a PH3 need?

Without electric backup, 19.8 to 40 A (MCA) on single-phase and 21.8 to 29.5 A on three-phase, by tonnage. Electric backup adds its own calculation: we do it with your panel at the visit.

Is the PH3 loud?

70.3 to 72.9 dB(A) in cooling on single-phase and 72 dB(A) on three-phase, as sound power under AHRI 270.

Sources and dates checked

  1. YORK, Technical Guide: PH3 Series, 208 V/230 V single-phase (6677783-UTG-B-0925, September 25, 2025) and three-phase (6803988-UTG-A-0526, May 6, 2026): warranty, features, nomenclature, application limits, physical data, sound and electrical data; read October 27, 2026.
  2. Hydro-Québec, LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by model number.
  3. airgreen.ca product pages: model numbers, tonnages and power supplies of the 43 YORK packaged units we carry, read October 27, 2026.

Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.