Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
YORK PH3 packaged heat pump: 2 to 5 tons, single- or three-phase
The PH3 is YORK’s residential packaged unit in
Two footprints, four heights: 44 to 55 in. by tonnage.
YORK PH3 technical guides, physical data; 51 1/4 in. long for all.
Four PH3 units, 24,000 to 60,000 BTU/h.
Select a tonnage: ratings, cabinet, sound and both possible circuits.
- Net cooling (AHRI)
- 23,800 BTU/h13.4 SEER2 · 11.1 EER2
- Heating at 8.3 °C
- 22,200 BTU/hCOP 3.8 · HSPF2 6.7
- Heating at −8.3 °C
- 13,000 BTU/h
- Cabinet L × W × H
- 51 1/4 × 35 3/4 × 44 in.340 lb per YORK
- Nominal airflow
- 875 CFM
- Outdoor sound (AHRI 270)
- 70.3 dB(A)
single-phase , cooling Single-phase circuit- 19.8 A · 30 AMCA · max. protection, no backup heat
Three-phase circuit- no
three-phase version at 2 tons R-454B charge- 4 lb 1 oz
- Outdoor range
- heats down to −18 °Ccools from 13 to 52 °C
- Net cooling (AHRI)
- 35,400 BTU/h13.4 SEER2 · 11.1 EER2
- Heating at 8.3 °C
- 34,000 BTU/hCOP 3.6 · HSPF2 6.7
- Heating at −8.3 °C
- 21,000 BTU/h
- Cabinet L × W × H
- 51 1/4 × 45 3/4 × 47 in.423 lb per YORK
- Nominal airflow
- 1,200 CFM
- Outdoor sound (AHRI 270)
- 72.9 dB(A)
single-phase , cooling;three-phase : 72 dB(A) Single-phase circuit- 27.3 A · 40 AMCA · max. protection, no backup heat
Three-phase circuit- 21.8 A · 30 AMCA · max. protection, no backup heat
R-454B charge- 7 lb 5 oz
- Outdoor range
- heats down to −18 °Ccools from 13 to 52 °C
- Net cooling (AHRI)
- 48,500 BTU/h13.4 SEER2 · 11.1 EER2
- Heating at 8.3 °C
- 47,000 BTU/hCOP 3.7 · HSPF2 6.7
- Heating at −8.3 °C
- 28,600 BTU/h
- Cabinet L × W × H
- 51 1/4 × 45 3/4 × 50 in.482 lb per YORK
- Nominal airflow
- 1,700 CFM
- Outdoor sound (AHRI 270)
- 71.6 dB(A)
single-phase , cooling;three-phase : 72 dB(A) Single-phase circuit- 36.5 A · 50 AMCA · max. protection, no backup heat
Three-phase circuit- 24.5 A · 35 AMCA · max. protection, no backup heat
R-454B charge- 10 lb 14 oz
- Outdoor range
- heats down to −18 °Ccools from 13 to 52 °C
- Net cooling (AHRI)
- 57,500 BTU/h13.4 SEER2 · 11.1 EER2
- Heating at 8.3 °C
- 56,000 BTU/hCOP 3.4 · HSPF2 6.7
- Heating at −8.3 °C
- 34,200 BTU/h
- Cabinet L × W × H
- 51 1/4 × 45 3/4 × 55 in.499 lb per YORK
- Nominal airflow
- 1,825 CFM
- Outdoor sound (AHRI 270)
- 70.7 dB(A)
single-phase , cooling;three-phase : 72 dB(A) Single-phase circuit- 40.0 / 39.1 A · 60 AMCA · max. protection, no backup heat (208 V / 230 V)
Three-phase circuit- 29.5 A · 45 AMCA · max. protection, no backup heat
R-454B charge- 11 lb 5 oz
- Outdoor range
- heats down to −18 °Ccools from 13 to 52 °C
AHRI ratings as printed by YORK: 13.4 SEER2, 11.1 EER2 and 6.7 HSPF2 at all four tonnages. Heating rated at 47 °F (8.3 °C) and 17 °F (−8.3 °C). Performance is the same on single- and
The same PH3, not the same warranty.
Ratings and cabinet don’t change from one power supply to the other. The warranty YORK publishes changes completely.
Extended YORK warranty of 10 years on parts and compressor, with online registration within 90 days of installation. Offered from 2 to 5 tons. Electric backup from 5 to 25 kW nominal.
4 listings · code S21Standard YORK warranty: 1 year on parts, 5 years on the compressor. Offered from 3 to 5 tons. Smaller circuit (MCA 21.8 to 29.5 A), filter frame and filters shipped with the unit. Backup from 10 to 25 kW.
3 listings · code S31- Exact terms are confirmed in the quote; each version’s technical guide summarizes them this way.
- The power supply is in the model number: the 11th character is 2 for
single-phase and 3 forthree-phase .
The PH3, designed by YORK, installed by AirGreen.
AirGreen checks your electrical service, picks the tonnage and version, then installs the PH3 on its pad or roof curb and connects it to your ducts.
What YORK brings
- 13.4 SEER2,
R-454B At all four tonnages, with factory leak detection. - Two footprints35 3/4 in. wide at 2 tons, 45 3/4 in. from 3 to 5 tons.
- Removable base railsForklift from every side; two screws per corner.
What AirGreen brings
- Sold and installed by AirGreenIn Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free visitWe check the location, access, the ducts and the electrical service.
- Clear quoteThe exact model, what is included and the price, in writing.
- RBQ 5645-9605-01Subcategories 15.8, 15.10 and 16.
The result: the right PH3 for your home, installed by AirGreen.
All 7 PH3 units, right below.
One listing per tonnage and power supply; the model number says
What YORK builds into the PH3 cabinet.
The fan blows upward, above the cabinet.
G90 galvanized steel and powder coat, tested 1,000 hours in salt spray.
Forklift access from every side; two screws per corner to remove them when height is short.
Defrost curves preloaded in the board, matched to the unit’s capacity.
Slotted, it protects the outdoor coil.
Twelve characters, and the eleventh decides the warranty.
Select a model. The 2 or 3 in second-to-last position tells single- or
- PHPackaged heat pump, optional electric heat
- 313.4 SEER2
- E
R-454B refrigerant - 2424,000 BTU/h nominal
- N00Electric type, no factory kit (N00): 6HK backup added on site if needed
- SStandard conventional control
- 2208/230 V
single-phase - 1First generation
- PHPackaged heat pump, optional electric heat
- 313.4 SEER2
- E
R-454B refrigerant - 3636,000 BTU/h nominal
- N00Electric type, no factory kit (N00): 6HK backup added on site if needed
- SStandard conventional control
- 2208/230 V
single-phase - 1First generation
- PHPackaged heat pump, optional electric heat
- 313.4 SEER2
- E
R-454B refrigerant - 4848,000 BTU/h nominal
- N00Electric type, no factory kit (N00): 6HK backup added on site if needed
- SStandard conventional control
- 2208/230 V
single-phase - 1First generation
- PHPackaged heat pump, optional electric heat
- 313.4 SEER2
- E
R-454B refrigerant - 6060,000 BTU/h nominal
- N00Electric type, no factory kit (N00): 6HK backup added on site if needed
- SStandard conventional control
- 2208/230 V
single-phase - 1First generation
- PHPackaged heat pump, optional electric heat
- 313.4 SEER2
- E
R-454B refrigerant - 3636,000 BTU/h nominal
- N00Electric type, no factory kit (N00): 6HK backup added on site if needed
- SStandard conventional control
- 3208/230 V
three-phase - 1First generation
- PHPackaged heat pump, optional electric heat
- 313.4 SEER2
- E
R-454B refrigerant - 4848,000 BTU/h nominal
- N00Electric type, no factory kit (N00): 6HK backup added on site if needed
- SStandard conventional control
- 3208/230 V
three-phase - 1First generation
- PHPackaged heat pump, optional electric heat
- 313.4 SEER2
- E
R-454B refrigerant - 6060,000 BTU/h nominal
- N00Electric type, no factory kit (N00): 6HK backup added on site if needed
- SStandard conventional control
- 3208/230 V
three-phase - 1First generation
In blue, the characters that change from one listing to the next in this series. Read from the nomenclature YORK prints in the technical guide; the unit’s nameplate prevails.
The PH3’s limits, in numbers.
- A field-supplied, field-installed electrical disconnect switch is mandatory, according to YORK.
- Side-to-bottom duct conversion without cutting: the two bottom panels move onto the side openings.
None of the 7 packaged units on this page is on
What people ask us about the PH3.
Does the PH3 come in 2 tons?
Yes, and it’s the only 2-ton packaged unit in our catalogue: the PH3E24N00S21, on 208/230 V
Why does the warranty differ between single- and three-phase ?
That’s what YORK publishes: 10 years on parts and compressor with online registration within 90 days for the
How cold does the PH3 heat?
Down to 0 °F (−18 °C) outdoors, per YORK’s application limits. Below that, the electric backup takes over; we size it at the visit.
What circuit does a PH3 need?
Without electric backup, 19.8 to 40 A (MCA) on
Is the PH3 loud?
70.3 to 72.9 dB(A) in cooling on
Your PH3, at the right tonnage and voltage, installed by AirGreen.
At the free visit, we read your electrical service, choose the version and tonnage, and plan the electric backup.
Sources and dates checked
- YORK, Technical Guide: PH3 Series, 208 V/230 V
single-phase (6677783-UTG-B-0925, September 25, 2025) andthree-phase (6803988-UTG-A-0526, May 6, 2026): warranty, features, nomenclature, application limits, physical data, sound and electrical data; read October 27, 2026. Hydro-Québec , LogisVert eligible heat pump list, file of October 26, 2026, “homeowner, existing house” profile, searched by model number.- airgreen.ca product pages: model numbers, tonnages and power supplies of the 43 YORK packaged units we carry, read October 27, 2026.
Price on quote. YORK® is a registered trademark, used here to identify the products we sell and install.