Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
-
Added to comparison
WindFree Standard: summer without drafts, winter down to -20.6 °C.
The same WindFree mode as the Max Heat, the same built-in Wi-Fi, the same five sizes. ENERGY STAR certified, it heats down to -20.6 °C outside. It belongs in homes where baseboards, a furnace or a central heat pump keep things warm below -20.6 °C. LogisVert: $545 to $1,020.
- ENERGY STAR
- Narrowest head of the ten (9,000 and 12,000)
- Built-in Wi-Fi, SmartThings
It heats down to -20.6 °C (-5 °F). Below that, another heat source takes over.
Samsung WindFree Standard submittal (version 10072024).
No LogisVert on the 9,000, $545 to $1,020 on the other four.
Pick a size: model numbers, AHRI number, certified heat at -8 °C and the math at the ENERGY STAR rate of $50 per 1,000 BTU/h.

Not sure about the size? We work it out on site: insulation, windows, orientation, ceiling height.

WindFree Standard · 9,000 BTU/h
AR09DXFAMWKNCV + AR09DXFAMWKXCV · AHRI 215399298
Under 12,000 BTU/h: below the LogisVert minimum.

WindFree Standard · 12,000 BTU/h
AR12DXFAMWKNCV + AR12DXFAMWKXCV · AHRI 215399297
Amount on Hydro-Québec’s LogisVert list (Oct. 14, 2026), $50 / 1,000 BTU/h at -8 °C
Same size in Max Heat: $1,272 in LogisVert, and heating down to -30 °C.

WindFree Standard · 15,000 BTU/h
AR15DXFAMWKNCV + AR15DXFAMWKXCV · AHRI 215351563
Amount on Hydro-Québec’s LogisVert list (Oct. 14, 2026), $50 / 1,000 BTU/h at -8 °C
Same size in Max Heat: $1,680 in LogisVert, and heating down to -30 °C.

WindFree Standard · 18,000 BTU/h
AR18DXFAMWKNCV + AR18DXFAMWKXCV · AHRI 215222780
Amount on Hydro-Québec’s LogisVert list (Oct. 14, 2026), $50 / 1,000 BTU/h at -8 °C
Same size in Max Heat: $2,100 in LogisVert, and heating down to -30 °C.

WindFree Standard · 24,000 BTU/h
AR24DXFAMWKNCV + AR24DXFAMWKXCV · AHRI 215222784
Amount on Hydro-Québec’s LogisVert list (Oct. 14, 2026), $50 / 1,000 BTU/h at -8 °C
Same size in Max Heat: $2,640 in LogisVert, and heating down to -30 °C.
Below -20.6 °C, will your wall unit be on its own?
If yes, go Max Heat. If baseboards, a furnace or a central system take over, Standard is enough.
Other systems, for example: baseboard heaters, a furnace, a central heat pump. We look at the house with you during the visit.
WindFree Standard is the right fit.
It cools without drafts and heats down to -20.6 °C; in deep cold, your other system takes over. It is ENERGY STAR certified: LogisVert from $545 to $1,020.
Look at the WindFree Max Heat instead.
Same WindFree mode, same Wi-Fi, but it heats down to -30 °C and keeps 100% of its capacity down to -20 °C, per Samsung. It is cold-climate certified: LogisVert from $1,272 to $2,640.
The LogisVert gap between the two series, size by size, is on the Max Heat page: it is the Max Heat’s advantage, not the Standard’s.
At least 19 hours each January below its -20.6 °C limit.
The National Building Code sets Montreal’s 2.5% January design temperature at -23 °C: on average, 19 January hours are colder. For those hours at least, the Standard does not heat and your other heating takes over.
Real cold, and where the unit stops
Average number of days per month when the low drops below the threshold (1991-2020 normals).
Source: Environment and Climate Change Canada, Canadian Climate Normals 1991-2020, Montreal-Trudeau (airport) station, checked Oct 8, 2026. Design temperatures: National Building Code of Canada 2020, Appendix C, Table
Below -20.6 °C, your baseboards take over. Samsung planned for it.
Standard stops heating below -20.6 °C. With the
The heat pump heats
When temperatures rise, Samsung restricts the backup source and lets the heat pump do the heating.
Backup takes priority
In deep cold, you can make your backup source the priority. Below -20.6 °C, the Standard stops heating: the backup does all the work.
The backup starts on its own
If the heat pump shows certain error codes, the backup can start on its own.
Samsung also lets the installer set the head’s fan during backup heat, defrost and emergency heat. Settings are made at installation; the hookup to your baseboards is checked at the visit.
Source: samsunghvac.com, WindFree Standard page, “Smart Heat Source Management” and “Emergency Heat Operation”, read Oct 9, 2026; WindFree Standard submittals (10072024A): “External heat control functionality… (
At -8 °C, the Standard 12,000 out-heats the Max Heat.
Per ENERGY STAR, the Standard matches or beats the Max Heat at some temperatures. Pick a size and see where the lines cross.
WindFree StandardWindFree Max Heat
Tied at 8.3 °C. At -8 °C, Standard leads by 100 BTU/h. At -15 °C, Max Heat leads by 1,000.
| BTU/h | Standard | Max Heat | Gap (Standard) |
|---|---|---|---|
| 8.3 °C (47 °F) | 11,000 | 11,000 | tied |
| -8 °C (17 °F) | 10,000 | 9,900 | +100 |
| -15 °C (5 °F) | 7,500 | 8,500 | -1,000 |
Tied at 8.3 °C. At -8 °C, Standard leads by 300 BTU/h. At -15 °C, Max Heat leads by 1,000.
| BTU/h | Standard | Max Heat | Gap (Standard) |
|---|---|---|---|
| 8.3 °C (47 °F) | 12,000 | 12,000 | tied |
| -8 °C (17 °F) | 10,900 | 10,600 | +300 |
| -15 °C (5 °F) | 8,000 | 9,000 | -1,000 |
Tied at 8.3 °C, then Max Heat pulls ahead: 1,000 at -8 °C, 5,100 at -15 °C.
| BTU/h | Standard | Max Heat | Gap (Standard) |
|---|---|---|---|
| 8.3 °C (47 °F) | 15,000 | 15,000 | tied |
| -8 °C (17 °F) | 13,000 | 14,000 | -1,000 |
| -15 °C (5 °F) | 10,500 | 15,600 | -5,100 |
Standard leads at 8.3 °C (21,000 vs 20,000). Max Heat takes over at -8 °C (2,500) and -15 °C (1,800).
| BTU/h | Standard | Max Heat | Gap (Standard) |
|---|---|---|---|
| 8.3 °C (47 °F) | 21,000 | 20,000 | +1,000 |
| -8 °C (17 °F) | 15,000 | 17,500 | -2,500 |
| -15 °C (5 °F) | 12,500 | 14,300 | -1,800 |
Here Max Heat leads everywhere: 1,000, 1,600, then 1,200 BTU/h.
| BTU/h | Standard | Max Heat | Gap (Standard) |
|---|---|---|---|
| 8.3 °C (47 °F) | 24,000 | 25,000 | -1,000 |
| -8 °C (17 °F) | 20,400 | 22,000 | -1,600 |
| -15 °C (5 °F) | 17,300 | 18,500 | -1,200 |
At -8 °C, this heat is what LogisVert uses. Standard 12,000: 10.9 × $50 = $545. Max Heat 12,000: 10.6 × $120 = $1,272. The cold-climate certification sets the rate, not the heat alone.
Source: ENERGY STAR, dataset w7cv-9xjt, fields “heating_capacity_at_47_f”, “_17_f” and “_5_f”, by AHRI number, read Oct 9, 2026; heating limits: Samsung submittals (10072024A); LogisVert rates: Hydro-Québec.
From $545 to $1,020 for a WindFree Standard.
Standard is ENERGY STAR certified, without the cold-climate tier: Hydro-Québec gives $50 per 1,000 BTU/h of heat at -8 °C. Pick a size to see the math and your deadline.
AR24DXFAMWKNCV + AR24DXFAMWKXCV · AHRI 215222784
AR18DXFAMWKNCV + AR18DXFAMWKXCV · AHRI 215222780
AR15DXFAMWKNCV + AR15DXFAMWKXCV · AHRI 215351563
AR12DXFAMWKNCV + AR12DXFAMWKXCV · AHRI 215399297
AR09DXFAMWKNCV + AR09DXFAMWKXCV · AHRI 215399298
Under 12,000 BTU/h: below the LogisVert minimum.
July 8, 2027
Source: Hydro-Québec, list of heat pumps eligible for LogisVert, file of Oct. 14, 2026 (owner, existing home), by AHRI number; Participation guide v1.10 (Sept. 15, 2026). Hydro-Québec’s list prevails; the final amount is confirmed when you apply. The program rules are explained once, on the Samsung page.
The 15,000: its own outdoor unit, the line’s best numbers.
Of the five Standards, it is the only one with a 34 5/8 × 25 1/8 in outdoor unit, and it leads the line on HSPF2 and COP at -15 °C. Not on everything: pick a measure.
The 15,000 leads with 10.0. The others: 9.0 or 8.0.
The 15,000 leads with 2.38. The others: 1.76 to 2.09.
Here the 24,000 leads (72.1%). The 15,000 follows at 70.0%.
In cooling, the 9,000 leads (25.0). The 15,000 sits at 21.5, tied with the 18,000.
83.3 lb and 40.6 oz of factory
Source: ENERGY STAR records by AHRI number (dataset w7cv-9xjt), read Oct 9, 2026; Samsung Standard 15,000 submittal (10072024A); Samsung installation manual, charge table. Heat kept: heat at -15 °C ÷ heat at 8.3 °C, AirGreen calculation.
The WindFree Standard, size by size.
Size, weight, sound, line limits and cold-weather heat: the numbers from Samsung’s submittals and ENERGY STAR, drawn out. Pick a size.
Outdoor unit · 69.2 lb
Indoor unit · 20.3 lb
Sound in dB(A), with references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Outdoor unit · 69.2 lb
Indoor unit · 20.3 lb
Sound in dB(A), with references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Outdoor unit · 83.3 lb
Indoor unit · 25.4 lb
Sound in dB(A), with references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Outdoor unit · 108.0 lb
Indoor unit · 25.4 lb
Sound in dB(A), with references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Outdoor unit · 150.4 lb
Indoor unit · 25.4 lb
Sound in dB(A), with references
Rustling leaves30
Whisper40
Quiet library50
Moderate rain60
Conversation
References in dB: American Academy of Audiology. The unit’s values are those Samsung publishes, in dB(A); the references only give a sense of scale.
Sources: Samsung WindFree submittals (version 10072024A); heat and COP at -15 °C: ENERGY STAR, dataset w7cv-9xjt, by AHRI number, Oct 8, 2026. Indoor unit W × H × D. Sound: Samsung publishes Silent mode and high speed.
The full plate, size by size.
The five WindFree™ Standard sizes side by side, with Samsung’s own terms under each row. Where Samsung publishes nothing, the cell says so.
| Nominal BTU/h | 9,000 | 12,000 | 15,000 | 18,000 | 24,000 |
|---|---|---|---|---|---|
| Identification | |||||
| Indoor unitIndoor unit | |||||
| Outdoor unitOutdoor unit | |||||
| AHRI numberAHRI Certified Ref. No. | 215399298 | 215399297 | 215351563 | 215222780 | 215222784 |
| ENERGY STAR IDENERGY STAR Unique ID | 3621246 | 3621245 | 3621099 | 3554499 | 3554503 |
| LogisVert, Hydro-Québec listOct. 14, 2026 | not listed (under 12,000 BTU/h) | $545 | $650 | $750 | $1,020 |
| Heating | |||||
| Rated capacity, cooling / heatingRated capacity (BTU/h) | 9,000 / 11,000 | 12,000 / 12,000 | 15,000 / 15,000 | 18,000 / 21,000 | 22,000 / 24,000 |
| Heat at 8.3 / -8.3 / -15 °CENERGY STAR, 47 / 17 / 5 °F | 11,000 / 10,000 / 7,500 | 12,000 / 10,900 / 8,000 | 15,000 / 13,000 / 10,500 | 21,000 / 15,000 / 12,500 | 24,000 / 20,400 / 17,300 |
| COP at 8.3 / -8.3 °CNEEP, 47 / 17 °F | 4.03 / 2.44 | 3.82 / 3.04 | 3.96 / 2.72 | 3.42 / 2.71 | not published |
| COP at -15 °CENERGY STAR, 5 °F | 1.91 | 1.76 | 2.38 | 2.09 | 1.92 |
| Coldest certified point, -20.6 °C (NEEP)NEEP | up to 9,000 BTU/h · COP 1.88 | up to 10,000 BTU/h · COP 1.81 | up to 10,800 BTU/h · COP 1.98 | up to 11,500 BTU/h · COP 1.98 | not published |
| Efficiency | |||||
| SEER2 / EER2AHRI 210-240 2023 | 25.0 / 15.00 | 24.0 / 13.25 | 21.5 / 12.95 | 21.5 / 12.85 | 20.0 / 12.20 |
| HSPF2, region IV / region VSamsung · NEEP | 9.0 / 8.5 | 9.0 / 8.5 | 10.0 / 10.0 (to confirm*) | 9.0 / 8.5 | 8.0 / not published |
| Sound | |||||
| Indoor, Silent / HighSound pressure, dB(A) | 22 / 38 | 22 / 39 | 27 / 41 | 27 / 41 | 30 / 45 |
| Outdoor, cooling highSound pressure, dB(A) | 45 | 46 | 51 | 51 | 54 |
| Test conditions | not published | not published | not published | not published | not published |
| Installation | |||||
| Power · MCA / MOP208-230 V, 1 ph, 60 Hz | 12 A / 20 A | 12 A / 20 A | 16 A / 25 A | 16 A / 25 A** | 21 A / 30 A |
| Line setLiquid / gas (in) | 1/4 + 3/8 in | 1/4 + 3/8 in | 1/4 + 1/2 in | 1/4 + 1/2 in | 1/4 + 5/8 in |
| Max length / max riseft | 66 / 49 ft | 66 / 49 ft | 98 / 66 ft | 98 / 66 ft | 98 / 66 ft |
| Factory charge, for 24.6 ft | 34.0 oz | 34.0 oz | 40.6 oz | 52.9 oz | 70.6 oz |
| Outdoor W × H × D · weightin · lb | 31 1/8 × 21 9/16 × 11 1/4 in · 69.2 lb | 31 1/8 × 21 9/16 × 11 1/4 in · 69.2 lb | 34 5/8 × 25 1/8 × 12 3/16 in · 83.3 lb | 34 5/8 × 31 7/16 × 12 3/16 in · 108.0 lb | 37 × 39 5/16 × 13 in · 150.4 lb |
| Indoor W × H × D · weightin · lb | 32 5/16 × 11 3/4 × 8 7/16 in · 20.3 lb | 32 5/16 × 11 3/4 × 8 7/16 in · 20.3 lb | 41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lb | 41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lb | 41 9/16 × 11 3/4 × 8 7/16 in · 25.4 lb |
- How to read its model numbers: Samsung writes them with wildcards (AR**DX…) and does not explain each character.
- The test conditions behind the sound levels, and the sound at the middle fan speeds.
- The remote control’s model number and the filter-cleaning interval (the owner’s manual is not on a Samsung site).
Sources: Samsung submittals (10072024A); ENERGY STAR (w7cv-9xjt); NEEP, read by AHRI number on Oct. 14, 2026; Hydro-Québec’s LogisVert list of Oct. 14, 2026. HSPF2 region V comes from NEEP: Samsung prints region IV only. ** Standard 18,000: the Samsung submittal (10072024A) gives MCA 16 A and max breaker 25 A; Samsung’s technical catalog of Sept. 30, 2026 gives 21 A and 30 A. We read the nameplate of the unit delivered before choosing the breaker. The 24,000 is not on the NEEP list: no coldest point and no COP at 8.3 and -8.3 °C published for it. * 15,000: NEEP lists 10.0 in region V, the same as region IV, while the other sizes show 8.5; we flag it rather than rely on it until Samsung confirms it.
32 5/16 in: the narrowest head of our ten Samsung wall units.
At 9,000 and 12,000, the Standard head is 68 mm narrower than the same-size Max Heat. In a small bedroom, between the corner and the window, that can settle it. Slide to measure.
125 mm (5 in) to the wallthe headend of the space (window, door…)
Head: 20.3 lb (Standard 9,000 and 12,000) · 23.1 lb (Max Heat 9,000 and 12,000) · 25.4 lb (Standard 15,000 to 24,000) · 27.3 lb (Max Heat 15,000 to 24,000).
Samsung’s manual asks for 125 mm (5 in) between the head and the wall. On the window side, we check on site: the manual only gives the wall figure. AirGreen calculation: head width + 5 in.
Source: Samsung WindFree Standard and Max Heat submittals (10072024A), dimensions; Samsung AR**DX*** installation manual, “Minimum clearance requirements” figure.
The Standard, in six claims.
True or false? Each card flips to the answer and its source.
The Standard 18,000 has a better SEER2 than the Max Heat 18,000.
The Standard heats down to -25 °C.
The Standard 15,000 and 18,000 have the same indoor head size.
The wall unit has a built-in humidity sensor.
The Standard keeps cooling at -15 °C outside.
The outdoor coil went through 240 hours of salt spray.
These apply to every Samsung wall unit: they have their own page, so we don’t repeat them here.
What people ask about the Standard.
Down to -20.6 °C (-5 °F) outside, per the Samsung submittal. Below that, you need another heat source.
Standard is ENERGY STAR certified, but not cold climate: Hydro-Québec gives $50 per 1,000 BTU/h of heat at -8 °C, instead of $120.
It stops heating, per its Samsung submittal. With the
At 9,000 and 12,000, yes: 32 5/16 in wide against 35 in for the Max Heat, and 20.3 lb. From 15,000 to 24,000, both heads are 41 9/16 in.
Yes, with the
Not always. Per ENERGY STAR, at -8 °C the Standard 9,000 gives 10,000 BTU/h against 9,900, and the 12,000 gives 10,900 against 10,600. At -15 °C, the Max Heat pulls ahead.
No. All five sizes are ENERGY STAR certified, but none is listed as “cold climate”. Even the 15,000, which keeps exactly 70% of its heat at -15 °C per ENERGY STAR, is not. That is why Hydro-Québec’s list pays it $50 per 1,000 BTU/h at -8 °C, not $120.
Per NEEP, read by AHRI number on Oct. 14, 2026, its maximum capacity at -20.6 °C (-5 °F) runs from 9,000 BTU/h (9,000) to 11,500 BTU/h (18,000), with a COP of 1.81 to 1.98. The 24,000 is not on the NEEP list.
No question matches. Call us: 514 316-2973.
Heating the whole house? Look at Hylex on your ducts.
Standard looks after one room. For several rooms on one outdoor unit, or a house with ducts, here’s the rest of the Samsung range.

2, 3 or 4-head multi-zone
FJM Premium: up to 4 rooms on one outdoor unit.
See the collection
Hylex central heat pumps
Standard and Premium, 2 to 5 tons, on your ducts.
See the collection
“Add-on” central systems
A Hylex coil on the furnace you keep.
See the collection
Hylex electric furnaces
The Hylex indoor unit in place of an electric furnace.
See the collection
SAMSUNG ducted units
Slim duct hidden in a ceiling or closet.
See the collection
SAMSUNG ceiling cassettes
WindFree mini 4-way cassette, 2 × 2 ft.
See the collection
SAMSUNG floor consoles
Low on the wall, often under a window.
See the collection
SAMSUNG thermostats and Wi-Fi
Wired controllers and Wi-Fi adapter.
See the collectionYour WindFree Standard, chosen with you and installed by AirGreen.
We come see the room and your current heating, pick the size with you and hand you a clear quote with the AHRI number and the indicative LogisVert amount.
Hydro-Québec does no phone or door-to-door solicitation for LogisVert. A call “from Hydro-Québec” selling a heat pump? Hang up.


Sources checked on October 14, 2026
- Samsung HVAC, “Residential & Light Commercial Tech Catalog” (Sept. 30, 2026), samsunghvac.com, read Oct. 14, 2026.
- NEEP, Cold Climate Air Source Heat Pump List, records read by AHRI number on Oct. 14, 2026 (test points, COP, coldest certified point).
- Hydro-Québec, list of heat pumps eligible for LogisVert (owner, existing home), file of Oct. 14, 2026: amounts and “capacity at -8 °C”.
- Samsung WindFree Standard and WindFree Max Heat submittals, 9,000 to 24,000 BTU/h (version 10072024).
- ENERGY STAR, Certified Air-Source Heat Pumps (dataset w7cv-9xjt), queried by AHRI number on Oct. 8, 2026.
- Hydro-Québec, residential LogisVert page and LogisVert Participation Guide v1.10 (Sept. 15, 2026), checked Oct. 8, 2026.
- Samsung HVAC 2026 spec sheets and warranty registration page (samsunghvac.com), checked Oct. 8, 2026.
- airgreen.ca product pages, Oct. 8, 2026.
- Environment and Climate Change Canada, Canadian Climate Normals 1991-2020, Montreal-Trudeau; National Building Code of Canada 2020, Appendix C.
- American Academy of Audiology, “Levels of Noise in Decibels”, 2023 (sound references).
- Samsung HVAC, WindFree Standard page (Smart Heat Source Management, Emergency Heat Operation), checked Oct 9, 2026.
- ENERGY STAR, “Heat Pump Equipment Key Product Criteria” and records by AHRI number (dataset w7cv-9xjt), read Oct 9, 2026.
- National Building Code of Canada 2020, Appendix C, definition of January design temperatures (CBHCC public review copy).
LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quote.
All five WindFree Standard units, right below.
From 9,000 to 24,000 BTU/h: open the product page for dimensions, sound level and full performance data.