Seven sizes, from 6,000 to 33,000 BTU/h, all ENERGY STAR cold-climate certified, three of which no other Senville wall series offers: 6,000, 15,000 and 33,000. NEEP publishes a point at −30 °C for six of them; the 15,000 stops at −25 °C. The 33,000 earns $3,840 of indicative LogisVert, the highest amount among our Senville wall units.
“Arctic Series (Up to -30°C)”R-454BENERGY STAR cold climate, 7 sizes of 710 years compressor · 5 years parts
Updated October 26, 2026 · ENERGY STAR, NEEP, Hydro-Québec, Senville and its AURA manuals
Maximum capacity · BTU/h
What is left at the coldest published point
6,0003,200
9,0005,100
12,0005,900
15,0007,800
18,0008,000
24,00011,900
33,00020,700
at −30 °Cat −25 °C, AURA 15,000
Maximum capacity reported to NEEP, by size, in BTU/h; data checked October 26, 2026.
7 of 7sizes ENERGY STAR cold-climate certified
20,700BTU/h maximum at −30 °C for the AURA 33,000, the highest among our Senville wall units
$3,840indicative LogisVert for the AURA 33,000
50 mof line set at most, AURA 24,000 and 33,000 (installation manual)
This page answersFor anyone who wants a Senville wall unit that still heats in the middle of January: which AURA size for which room, what each one certifiably delivers at −8.3, −15 and −30 °C, and the three sizes only the AURA comes in.
Seven rungs, from 6,000 to 33,000 BTU/h: find yours
In deep cold, heat is what counts, not the cooling label. Each rung gives, for one size, the certified heat at −15 °C and at the coldest published point, the LogisVert amount, the line-set sizes and the maximum length set by the manual. At the visit we assess the room, then pick the rung.
rated capacity at −15 °Cmaximum capacity at −30 °Cmaximum capacity at −25 °Cbars to scale, 0 to 36,000 BTU/h
6,000BTU/hSENA-06HFAURA only
Certified heat
7,700 BTU/h at −15 °C · COP 2.40
3,200 BTU/h at −30 °C, maximum · COP 1.23
LogisVert, indicative$0rated cooling under 12,000 BTU/h
Line set1/4 in · 3/8 inliquid · suction, PJX-1 kit
Max. length · drop25 m · 15 m82 ft · 49.2 ft
9,000BTU/hSENA-09HF
Certified heat
11,500 BTU/h at −15 °C · COP 1.80
5,100 BTU/h at −30 °C, maximum · COP 1.11
LogisVert, indicative$0rated cooling under 12,000 BTU/h
Line set1/4 in · 3/8 inliquid · suction, PJX-1 kit
Max. length · drop25 m · 15 m82 ft · 49.2 ft
12,000BTU/hSENA-12HF
Certified heat
11,500 BTU/h at −15 °C · COP 1.80
5,900 BTU/h at −30 °C, maximum · COP 1.25
LogisVert, indicative$1,44012,000 BTU/h at −8.3 °C × $120 per 1,000 BTU/h
Line set1/4 in · 3/8 inliquid · suction, PJX-1 kit
Max. length · drop25 m · 15 m82 ft · 49.2 ft
Senville suggests this size for 500–750 sq. ft.
15,000BTU/hSENA-15HFAURA only
Certified heat
11,500 BTU/h at −15 °C · COP 1.80
7,800 BTU/h at −25 °C, maximum · COP 1.41
LogisVert, indicative$1,44012,000 BTU/h at −8.3 °C × $120 per 1,000 BTU/h
Line setnot publishedsize missing from Senville’s article
Max. length · dropnot published15,000/33,000 manual linked by Senville not read
18,000BTU/hSENA-18HF
Certified heat
18,000 BTU/h at −15 °C · COP 1.92
8,000 BTU/h at −30 °C, maximum · COP 1.20
LogisVert, indicative$2,16018,000 BTU/h at −8.3 °C × $120 per 1,000 BTU/h
Line set1/4 in · 1/2 inliquid · suction, PJX-2 kit
Max. length · drop30 m · 20 m98.4 ft · 65.6 ft
Senville suggests this size for 750 to 1,000 sq. ft. (French product page).
24,000BTU/hSENA-24HF
Certified heat
24,200 BTU/h at −15 °C · COP 2.34
11,900 BTU/h at −30 °C, maximum · COP 1.45
LogisVert, indicative$2,66422,200 BTU/h at −8.3 °C × $120 per 1,000 BTU/h
Line set3/8 in · 5/8 inliquid · suction, PJX-3 kit
Max. length · drop50 m · 25 m164 ft · 82 ft
33,000BTU/hSENA-33HFAURA only
Certified heat
35,000 BTU/h at −15 °C · COP 1.98
20,700 BTU/h at −30 °C, maximum · COP 1.40
LogisVert, indicative$3,84032,000 BTU/h at −8.3 °C × $120 per 1,000 BTU/h
Line set3/8 in · 3/4 inliquid · suction, kit name not published
Max. length · drop50 m · 25 m164 ft · 82 ft
Heat: rated capacity at −15 °C and maximum capacity at the coldest point, published by NEEP (checked October 26, 2026). LogisVert: Hydro-Québec’s list, by AHRI number; nothing under 12,000 BTU/h of cooling. Line sizes: Senville help centre, article modified June 29, 2026, which leaves out the 15,000 and puts the 33,000 on the central-systems row. Length and drop: installation manual CS019UI-EP(R454B) of May 16, 2024, p. 47, with no row for the 15,000.
9,000, 12,000 or 15,000: the same certified heat below freezing
At −8.3 °C as at −15 °C, NEEP publishes the same rated capacities for these three AURA units: 12,000 then 11,500 BTU/h. What separates them lies elsewhere: cooling, seasonal efficiency, the coldest point and LogisVert.
AURA 9,000 BTU/h
The best seasonal efficiency of the three, with no LogisVert
Rated cooling
9,000 BTU/h
Heat at 8.3 °C
12,000 BTU/h
Heat at −8.3 °C
12,000 BTU/h · COP 2.49
Heat at −15 °C
11,500 BTU/h · COP 1.80
Coldest published point
−30 °C · 5,100 BTU/hmaximum, COP 1.11
SEER2 · HSPF2, region V
27.4 · 9.5
LogisVert, indicative
$0
AURA 12,000 BTU/h
The same heat below freezing, with $1,440 of LogisVert
Rated cooling
12,000 BTU/h
Heat at 8.3 °C
12,000 BTU/h
Heat at −8.3 °C
12,000 BTU/h · COP 2.51
Heat at −15 °C
11,500 BTU/h · COP 1.80
Coldest published point
−30 °C · 5,900 BTU/hmaximum, COP 1.25
SEER2 · HSPF2, region V
25.4 · 8
LogisVert, indicative
$1,440
AURA 15,000 BTU/h
More cooling, but a published point at −25 °C only
Rated cooling
15,000 BTU/h
Heat at 8.3 °C
15,000 BTU/h
Heat at −8.3 °C
12,000 BTU/h · COP 2.64
Heat at −15 °C
11,500 BTU/h · COP 1.80
Coldest published point
−25 °C · 7,800 BTU/hmaximum, COP 1.41
SEER2 · HSPF2, region V
23.5 · 7.5
LogisVert, indicative
$1,440
20,700BTU/h at −30 °C, AURA 33,000maximum capacity reported to NEEP, COP 1.40
It is the most heat published at −30 °C among the Senville wall units we sell: 1.7 times the next one (11,900 BTU/h). At the other end of the ladder, the AURA 6,000 keeps 3,200 BTU/h at that temperature.
Montreal drops below −30 °C on average 0.27 days a year (1981–2010 normals): this point shows the unit still runs in that cold, at reduced capacity.
The 15,000 is the exception in the series: its coldest published point on NEEP is −25 °C (7,800 BTU/h maximum, COP 1.41), and its senville.ca page also says −25 °C, while Senville files the AURA under its “Arctic Series (Up to -30°C)”. We show −25 °C for this size.
Capacities and COP: NEEP; SEER2 and HSPF2: ENERGY STAR and NEEP; LogisVert: Hydro-Québec; data checked October 26, 2026. Climate: Environment and Climate Change Canada, 1981–2010 normals, Montreal-Trudeau station.
03 · The models
The seven AURA units in detail: certification, heating, installation
One sheet per size, two per tab. Certified values from ENERGY STAR and NEEP; installation data from the senville.ca tables, read October 14, 2026.
AURA · 6,000 BTU/h
SENA-06HF
SENA-06HF-OG + SENA-06HF-IGG
Certification
Certificate
AHRI 215735294
ENERGY STAR
3630041 · cold climate
Refrigerant
R-454B
Cooling and seasonal efficiency
Rated cooling
6,000 BTU/h
SEER2 · EER2
25.5 · 18
HSPF2, regions IV · V
14.8 · 11.5
Certified heating
At 8.3 °C
7,000 BTU/h · COP 4.19
At −8.3 °C
8,700 BTU/h · COP 2.77
At −15 °C
7,700 BTU/h · COP 2.40
At −30 °C (maximum)
3,200 BTU/h · COP 1.23
Installation, per senville.ca
Power supply
208/230 V, single-phase, 60 Hzvoltage range 187–253 V
Minimum circuit ampacity
12 A
Maximum fuse
15 A
Indoor unit
33.40 × 9.18 × 11.76 in (848 × 233 × 299 mm)22.93 lb (10.4 kg)
Outdoor unit
30.12 × 11.93 × 21.85 in (765 × 303 × 555 mm)62.17 lb (28.2 kg)
The senville.ca tables print values other than the certified ones for several AURA units: HSPF2 of the 9,000, 12,000, 18,000 and 24,000 (13.7 and 9.6 for the 12,000, certified at 10.5 and 8), EER2 of the 9,000 and 12,000, rated heat at 8.3 °C of the 9,000, 12,000 and 18,000. We keep the certified values. Charge of the AURA 18,000: 55.38 oz on the English page, 50.91 oz on the French page. Sound: senville.ca values, with no test conditions. 15,000 weights: printed net weights.
04 · Day to day
Living with the AURA: functions, controls, what is in the box
Owner’s manual CS019UI-EP(R454B)
The functions Senville names
ECO
SLEEP
TURBO
SILENCE
Breeze Away
Active Clean
Louver Angle Memory
Refrigerant Leakage Detection
46 °F (8 °C) heating feature
Names as printed in the English manual of May 16, 2024. On its product pages, Senville also lists self-diagnostics and refrigerant leak detection.
Controls
CR333 remote, wall controller WRD-RMTIQ
Senville pairs the wall AURA with its WRD-RMTIQ wired controller and states that its mini splits do not work with regular household thermostats. The Alexa USB kit is in the box; the Senville app needs a Wi-Fi kit sold separately.
On its AURA pages, Senville includes a 16 ft (4.9 m) installation kit at no charge, with 25 or 50 ft as options; for the LETO, a kit comes only when selected. On site, the real length follows the route between the two units.
Sources: owner’s manual CS019UI-EP(R454B), May 16, 2024; senville.ca AURA pages, October 14, 2026; Senville help centre, “Which wall thermostats and controllers work with my Senville unit?”, modified October 8, 2026, read October 26, 2026.
Questions
What Senville publishes about the AURA, answered with the figures
Can I install the AURA myself?
No. Senville answers it on the AURA 12,000 page: “Professional installation is required for refrigerant handling, system commissioning”. See the warranty terms
Question published by Senville: “Can I install the system myself?”, FAQ of the SENA-12HF page on senville.ca, read October 14, 2026.
What is the warranty on the AURA?
10 years on the compressor and 5 years on parts, per Senville’s help centre and product pages. The French page of the AURA 18,000 is headed “Garantie de 10 ans”: that is the compressor; parts stay at 5 years. See the warranty terms
Question published by Senville: “What is the warranty on Senville products?”, help centre, modified October 8, 2026; SENA-18HF page on fr.senville.ca, October 14, 2026.
How often should I clean the AURA’s filter?
Every two weeks, per the AURA owner’s manual: “Make sure to clean the filter every two weeks.” Senville’s help centre, written for the whole range, says every 30 to 60 days, with a professional inspection once a year. For the AURA we follow the manual, which is stricter.
Question published by Senville: “How Often Should I Service My Mini Split?”, help centre, read October 14, 2026; owner’s manual CS019UI-EP(R454B), May 16, 2024, p. 16.
The room is far from the outside wall: how long can the line set be?
The AURA is pre-charged for 7.5 m (25 ft) of line set, with a 3 m minimum. Beyond 7.5 m, the installation manual calls for added R-454B: 0.16 oz per foot (15 g/m) on a 1/4 in liquid line, 0.32 oz per foot (30 g/m) on a 3/8 in line. Maximum length runs from 25 m (82 ft) for the 6,000 to 12,000 up to 50 m (164 ft) for the 24,000 and 33,000; for the 15,000, the dedicated 15,000/33,000 manual Senville links could not be read (not published here).
Question published by Senville (help centre, article on line-set size and length, read October 14, 2026); installation manual CS019UI-EP(R454B), May 16, 2024, p. 47.
AirGreen × SENVILLE
The right AURA rung, installed by AirGreen.
A visit to the room and the line-set route, the size picked on the ladder, then a quote naming your AURA’s AHRI certificate and its indicative LogisVert amount.
ENERGY STAR, Certified Air-Source Heat Pumps (data.energystar.gov, dataset w7cv-9xjt), records 3630041, 3630042, 3630043, 4479321, 3630045, 3630044 and 3630046, read October 14, 2026, re-checked unchanged October 26, 2026.
NEEP, Cold Climate Air Source Heat Pump List (ashp.neep.org), AHRI certificates 215735294, 215735295, 215735296, 217603532, 215735297, 215735298 and 215735299, read October 14, 2026, re-checked unchanged October 26, 2026.
Hydro-Québec, LogisVert eligible heat pump search tool, file read October 14, 2026, re-checked unchanged October 26, 2026; LogisVert residential participation guide, version 1.10, September 15, 2026.
Senville Canada, senville.ca: SENA-06HF, SENA-09HF, SENA-12HF (and its FAQ), SENA-15HF, SENA-18HF and SENA-24HF pages, “Arctic Series” category; fr.senville.ca: “Série arctique” category and SENA-18HF page, read October 14, 2026.
Senville, AURA owner’s manual and installation manual, CS019UI-EP(R454B), May 16, 2024 (p. 16 and p. 47), read October 14, 2026.
Senville help centre: “How to choose the right line set for your Senville system” (modified June 29, 2026), line-set size and length article, pre-charge article, “How Often Should I Service My Mini Split?” and “What is the warranty on Senville products?” (modified October 8, 2026), read October 14, 2026; “Which wall thermostats and controllers work with my Senville unit?” (modified October 8, 2026), read October 26, 2026.
Environment and Climate Change Canada, 1981–2010 climate normals, Montreal/Pierre Elliott Trudeau Intl A (7025250), read October 14, 2026.
airgreen.ca product pages, re-read October 26, 2026.
LogisVert amounts are indicative: Hydro-Québec confirms them when you apply. Prices on quotation.