AirGreenARCOAIRE
AirGreen × ARCOAIRE · Wall heat pumpOne unit on the wall, several lines to choose fromSold and installed by AirGreen across Montreal, Laval, Longueuil, the South Shore and the North Shore.
The full ARCOAIRE range
  1. Home
  2. ARCOAIRE
  3. Wall heat pump
ARCOAIRE wall heat pump · Updated October 29, 2026

Same size on the wall, very different heat in winter: compare the lines.

At 12,000 BTU/h, the maximum heat at -15 °C listed by NEEP ranges from 6,700 to 13,500 BTU/h depending on the line and the voltage. Pick a size: you see every ARCOAIRE wall unit we sell at that size, with its values listed by NEEP or certified by ENERGY STAR.

43ARCOAIRE wall heat pumps on our site
2refrigerants: R-454B and R-410A
16ENERGY STAR cold-climate certified in Canada
9,000 to 36,000BTU/h, from the bedroom to the large living room
01 · By size

At the same size, which line gives the most heat at -15 °C?

Tap a size. For each unit: the line as the brand prints it, the maximum heat at -15 °C listed by NEEP (or certified by ENERGY STAR when the unit is not in NEEP), the coldest point listed by NEEP, the SEER2 and the indicative LogisVert amount.

Wall unit size

The size is decided at the visit, room by room. Here you only compare what NEEP and ENERGY STAR Canada list for each unit sold at that size.

12,000 BTU/h
12wall units at this size

Most heat at -15 °C (NEEP or ENERGY STAR): 13,500 BTU/h, Deluxe R-454B (D5CPRAH12AAK).

ENERGY STAR cold-climate certified3
Wired for 115 V4
In neither NEEP nor ENERGY STAR Canada4

NEEP first, ENERGY STAR Canada otherwise, read October 28, 2026. The table below the tool lists every unit.

UnitLine, as the brand prints itMax. at -15 °CColdest point listed by NEEPSEER2Indicative LogisVert
R-454B
12,000 BTU/h
D5CPRAH12AAK
Deluxe13,500
NEEP
7,500
at -30 °C
28.0$1,320
12,000 BTU/h
D5CSHAH12AAK
Deluxe outdoor, QuietComfort head11,500
NEEP
5,900
at -30 °C
25.5$1,440
12,000 BTU/h · 115 V
D5CSRAH12AAJ
QuietComfort7,700
NEEP
4,000
at -25 °C
23.5$500
12,000 BTU/h
D5CERAH12AAK
Performance8,000
NEEP
no point below -15 °C21.4none on our sheets
12,000 BTU/h · 115 V
D5CERAH12AAJ
Performance7,000
NEEP
no point below -15 °C21.4none on our sheets
12,000 BTU/h
D5CVRAH12AAK
V line (no series name)7,000
NEEP
no point below -15 °C18.0none on our sheets
R-410A
12,000 BTU/h
DLCPRAH12AAK
Deluxe, 2018 generationnot listednot listednot listednone on our sheets
12,000 BTU/h
DLCSRBH12AAK
QuietComfort11,000
NEEP
6,000
at -30 °C
23.1$1,236
12,000 BTU/h · 115 V
DLCSRBH12AAJ
QuietComfort6,700
NEEP
no point below -15 °C22.7$445
12,000 BTU/h
DLCERBH12AAK
Performancenot listednot listednot listednone on our sheets
12,000 BTU/h · 115 V
DLCERBH12AAJ
Performancenot listednot listednot listednone on our sheets
12,000 BTU/h
DLCVRAH12AAK
V line (no series name)not listednot listednot listednone on our sheets

ENERGY STAR cold-climate certified wall units with no amount on our sheets are shown “to be confirmed” until Hydro-Québec’s list is read. “Not listed”: no NEEP or ENERGY STAR Canada record for that AHRI number. NEEP and ENERGY STAR list the D5CPRAH18AAK as model D5CPRAH18AA (records 389200 and 3624487). Only Hydro-Québec confirms the amount granted.

The shop

All 43 ARCOAIRE wall units, right below.

Each product gives the outdoor unit, the wall head, the AHRI number and, when there is one, the indicative LogisVert amount. Pricing by quote.

ARCOAIRE
02 · The series

Three series, two refrigerants: what the manufacturer prints.

The heating limit and the top efficiency each document states for the series. “Up to” values are for the best size, not every size.

Deluxe
R-454B · heats down to-22 °F
R-454B · SEER2 · HSPF2up to 33.1 · 15.6
R-410A · heats down to-22 °F
R-410A · SEER2 · HSPF2up to 27.0 · 17.5

R-454B: Deluxe brochure DLS-030-AR-02, p. 2; R-410A: 2024 catalogue DLS-001-AR-01, p. 12-13

See the R-410A page →
QuietComfort
R-454B · heats down to-13 °F
R-454B · SEER2 · HSPF2up to 26.0 · 13.9
R-410A · heats down to-22 °F
R-410A · SEER2 · HSPF2up to 28.1 · 13.6

R-454B: QuietComfort brochure DLS-031-AR-01, p. 2; R-410A: 2024 catalogue DLS-001-AR-01, p. 16, 18

See the R-410A page →
Performance
R-454B · heats down to5 °F
R-454B · SEER2 · HSPF2up to 22.4 · 9.4
R-410A · heats down to0 °F
R-410A · SEER2 · HSPF2up to 21.7 · 9.4

R-454B: Performance brochure DLS-043-AR-00, p. 2-3; R-410A: 2024 catalogue DLS-001-AR-01, p. 36-37

See the R-410A page →

The V line (DLCVRA in R-410A, D5CVRA in R-454B) carries no series name in the manufacturer’s product data, and the sheets we hold do not give its outdoor heating range. At NEEP, the D5CVRA units have no point listed below -15 °C. The R-454B QuietComfort states -13 °F (-25 °C), “may vary by model”. The R-454B Performance brochure prints 5 °F (-15 °C) as the series’ heating limit; NEEP lists a test point at -13 °F (-25 °C) for some sizes.

03 · 115 V

No 240 V at the panel? 115 V gives less heat at -15 °C.

The four 12,000 BTU/h wall units wired for 115 V, beside their 208/230 V version when we sell it.

12,000 BTU/h115 V, max. at -15 °C208/230 V, max. at -15 °C
The four 115 V wall units
Performance R-454B
D5CERAH12AAJ · D5CERAH12AAK
7,000
NEEP
8,000
NEEP
QuietComfort R-410A
DLCSRBH12AAJ · DLCSRBH12AAK
6,700
NEEP
11,000
NEEP
QuietComfort R-454B
D5CSRAH12AAJ
7,700
NEEP
no 208/230 V version sold
Performance R-410A
DLCERBH12AAJ · DLCERBH12AAK
not listednot listed

Maximums at 5 °F as listed by NEEP. The R-410A Performance is listed neither by NEEP nor by ENERGY STAR: “not listed”. The 2024 catalogue (p. 38) prints 6,272 and 8,000 BTU/h at 5 °F for its two 12,000 versions, with the DLFEHBH head, while our sheets pair it with the DLFEHAH head, which the manufacturer lists as compatible (p. 37).

Did you know

Three things the manufacturer’s documents tell you.

J = 115 V

The last letter of the model gives the voltage.

J means 115 V single phase, K means 208/230 V. A DLCSRBH12AAJ is wired for 115 V; a DLCSRBH12AAK for 208/230 V.

Catalogue DLS-001-AR-01, 03/2024, p. 71 (model decoder)
2 series

The D5CSHAH: a Deluxe outdoor unit with a QuietComfort head.

The manufacturer files the D5CSHAH under its Deluxe Series and pairs it with the QuietComfort D5FSHA wall head. The Deluxe wall head, the D5FPHA, goes with the D5CPRA.

Brochure DLS-030-AR-02, 06/2026, pp. 1 and 4
Stop

On the R-454B V line, a leak stops the compressor.

On models with the detector, the head shows a code and beeps, the compressor stops at once and the indoor fan starts running.

Product data D5FVHA31-01PD, 03/25, p. 2
04 · Questions

What people ask us about wall heat pumps.

Which line for a Montreal winter?

Look at the printed heating limit: -30 °C for the Deluxe (R-454B and R-410A) and the R-410A QuietComfort, -25 °C for the R-454B QuietComfort (may vary by model), -15 °C for the R-454B Performance and -17 °C for the R-410A Performance. Then compare the listed values in the tool. The choice is made at the visit.

115 V or 208/230 V?

We sell four 12,000 wall units in 115 V. Those listed by NEEP give less heat at -15 °C than their 208/230 V version (section 03). We check the electrical panel at the visit.

Why do some of our product titles not show the same series as this page?

Our product sheets keep older page names. Here, each unit carries the series name the manufacturer prints for it, when one of its documents covers it; for the 18,000 and 24,000 DLCPRA Deluxe, no document does, and we say so.

Is Wi-Fi included?

The manufacturer’s series table lists it built in on the Deluxe (except the D5CSHAH, whose QuietComfort head has optional Wi-Fi) and optional on the QuietComfort and the Performance; on the V line it is an optional module. For the 2018 Deluxe (DLCPRA), the catalogue sells it as a kit. We add it to the quote if you want it.

Can one wall unit heat the whole house?

It heats the room it is in first. For several rooms, we look at the floor plan at the visit: one head per room, or a multi-zone system.

What about LogisVert?

It is indicative and taken from our sheets. We show it when it matches the usual calculation (rated heat at -8 °C); otherwise it is shown “to be confirmed”. Only Hydro-Québec confirms the amount granted.

AirGreen × ARCOAIRE

One head per room, the right line for your winter.

We look at each room, the wall and the panel, then choose the line and the size. You get a quote with the system and its AHRI number.

RBQ licence 5645-9605-01Subclasses 15.8, 15.10 and 16. Gas and oil work is done by a licensed partner.
Free on-site estimateSize, line and voltage are decided at your home, once we have seen the rooms, the walls and the electrical panel.
Sold and installed by AirGreenMontreal, Laval, Longueuil, South Shore and North Shore.

Sources checked on October 29, 2026

  1. ARCOAIRE, ductless catalogue DLS-001-AR-01 (March 2024), pp. 12, 13, 16, 18, 36 to 38 and 71: DLCPRB, DLCSRB, DLCERBH, model decoder.
  2. ARCOAIRE, ductless catalogue 328-32-0499-00 (May 2018), pp. 15 and 16 (printed page numbers): DLCPRA.
  3. ARCOAIRE, brochures DLS-030-AR-02 (Deluxe Series, 06/2026), DLS-031-AR-01 (QuietComfort Series, 10/2024), DLS-043-AR-00 (Performance Series R-454B, 06/2026) and DLS-020-AR-01 (Performance Series R-410A and series table, 05/2024).
  4. ARCOAIRE, product data 32831004101 (DLFVHA, 04/21) and D5FVHA31-01PD (03/25).
  5. NEEP cold-climate heat pump list, records 389190, 389191, 389192, 389193, 389194, 389195, 389196, 389198, 389199, 389200, 389201, 389202, 391011, 391012, 391013, 391014, 391039, 391044, 391051, 391057, 391063, 403994, 404534, 406439, 406440, 406441, 406442, 505325, modified August 24, 2026, read October 28, 2026.
  6. ENERGY STAR, Certified Air-Source Heat Pumps, Canadian market, records 2410261, 2410262, 2410263, 2410264, 2410493, 2410592, 2410755, 2415674, 3556045, 3556051, 3556057, 3556064, 3556069, 3556093, 3556094, 3624485, 3624486, 3624487, 3624488, 3624490, 3624491, 3996155, 3996171, 3996237, 3996243, 3996244, 4478846, read October 28, 2026.
  7. airgreen.ca product sheets (AHRI numbers, indicative LogisVert amounts), re-read October 29, 2026.

LogisVert amounts are indicative. Only Hydro-Québec confirms the amount granted. Pricing by quote.