THERMO 2000 VoltMax SCR VOLTSCR480108P3 Commercial Electric Boiler | 108 kW - 480V 3 Phase

In stock

Thermo 2000’s VoltMax SCR 108 spreads 108 kW on 480 V three-phase across stages that take turns, with SCR modulation from 0 to 100%.

Model numberVOLTSCR480108P3

108 kW368,496 BTU/h
129.9 Aon 480 V three-phase
Rotationof stages by the controller
480 V · three-phaseReplaceable Incoloy elementsConfiguration B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberVOLTSCR480108P3
ManufacturerThermo 2000
Manufacturer designationVOLTMAX SCR 108-480-3 PH
Output108 kW (368,496 BTU/h)
Power supply480 V, three-phase, 60 Hz
Current129.9 A
Water volume30 US gal (113.5 L)

108 kW on 480 V, spread across stages that take turns

A high-capacity boiler for commercial and industrial buildings

The VoltMax SCR 108 (manufacturer designation: VOLTMAX SCR 108-480-3 PH) is a commercial electric boiler from Thermo 2000: 108 kW, or 368,496 BTU/h, on 480 V three-phase. It belongs to the series’ configuration B, with a 550 lb vertical cabinet holding 30 US gal of water.

We suggest it for buildings where hot-water heating runs long hours: a warehouse on the North Shore heated by unit heaters, a garage with a radiant floor in Longueuil, a commercial building whose air handling units have hot-water coils.

Sparing the elements, day after day

In a building this size, the boiler runs for much of the winter. Two mechanisms share the work. Solid-state relays (SCR) modulate output from 0 to 100% with demand, which, according to Thermo 2000, limits peak power. And the Schneider Electric controller rotates its stages, so the same elements are not always called on first.

These immersion elements are made of Incoloy and can be replaced. The day one of them needs changing, the job is on the element, not the boiler. Alarm codes on the screen, the web page and the Ethernet port’s email alarms help pinpoint what is going on quickly.

The rest of the data matters for design: 129.9 A on 480 V three-phase, four 2 1/2 in male NPT side connections, a maximum working pressure of 125 psi (862 kPa) as standard and a setpoint adjustable from 50 °F to 200 °F. The outdoor sensor is included, and the boiler communicates over BACnet IP or MS-TP if the building has a management system.

What AirGreen does

We first assess the building, free of charge and on site: 480 V service, mechanical room, loop, emitters, delivery route. The written quote we then give you includes the parts missing from Thermo 2000’s list, including the circulator and expansion tank.

Our crews deliver the boiler, set it in place within the published clearances (24 in in front, 32 in above, 3 in on the sides and back), connect the loop and the three-phase supply, mount the outdoor sensor, fill and purge the circuit. We then set up the controller with your maintenance lead.

Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in Montreal for more than fifteen years and holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.

Let’s talk about your building

In Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for a free estimate: you will receive a written quote, and financing is available.

01 · What it is for

108 kW for commercial and industrial buildings on 480 V

Warehouses, garages, workshops and sizeable commercial buildings are often heated with hot water through unit heaters, coils or radiant floors. The VoltMax SCR 108 supplies these loops on 480 V three-phase and rotates its stages so the same elements do not always run first.

  • Warehouses and distribution centres heated with hot water
  • Garages and workshops with radiant floors or hot-water unit heaters
  • Commercial buildings on 480 V three-phase
  • Replacing a high-capacity commercial electric boiler
Rotating stagesThe Schneider Electric controller rotates the stages, on top of SCR modulation from 0 to 100%.
Replaceable elementsIncoloy immersion elements that can be replaced one by one, according to Thermo 2000.
Clear alarmsOn-screen alarm codes, a web page and email alarms through the Ethernet port.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerThermo 2000
SeriesVoltMax SCR
Manufacturer designationVOLTMAX SCR 108-480-3 PH
TypeCommercial electric hot-water boiler, vertical design
Output108 kW
Output in BTU/h368,496 BTU/h
Power supply480 VAC, 60 Hz, three-phase
Current129.9 A
ModulationSCR 0 to 100% (solid-state relays) plus relay stages
ConfigurationB (99 to 180 kW models)
Water volume30 US gal (113.5 L)
Water connections2 1/2 in male NPT, 4 side connections
Relief valve and drain3/4 in female NPT
Max. working pressure125 psi (862 kPa), standard
Setpoint range50 °F to 200 °F (10 °C to 93 °C)
ControllerSchneider Electric, 3 in backlit LCD, alarm codes, French or English, °C or °F
CommunicationBACnet IP / MS-TP; Ethernet port with web page and email alarms
External control0-10 Vdc signal (setpoint and output)
FunctionsOutdoor reset, stage rotation, pump contact with or without domestic hot water priority, second setpoint for an indirect water heater
Outdoor sensorIncluded
Heating elementsImmersion type, Incoloy, replaceable
ClearancesSides 3 in, back 3 in, front 24 in, top 32 in, floor 0
Weight550 lb (250 kg)
Manufacturer warrantyThermo 2000: 10 years on the tank (limited warranty, closed-loop heating); 2 years on electrical and mechanical components (parts and accessories)
StandardsCSA C22.2 No. 165-92, UL 834, CSA B-51-14, CRN, ASME Section IV (H)
Model numberVOLTSCR480108P3
03 · Before installing

What to know before installing

  • 480 V three-phase, 60 Hz, 129.9 A according to Thermo 2000: service capacity is checked before the quote.
  • Configuration B: 550 lb (250 kg), 30 US gal of water, 2 1/2 in male NPT connections; delivery has to be planned.
  • Maximum working pressure of 125 psi (862 kPa) as standard, according to Thermo 2000.
  • The circulator and expansion tank are not supplied with the boiler: we add them to the quote.
  • Clearances: 24 in in front, 32 in above, 3 in on the sides and back.
In the box
  • Schneider Electric controller
  • Outdoor temperature sensor
  • ON/OFF control switch
  • Control and power fuses and breakers
  • SCR relays
  • Two limit controls, automatic and manual reset
  • Factory-installed relief valve
  • Drain valve
  • Low-water cut-off (standard above 60 kW)
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric boilers
See all
Same brand
THERMO 2000
See all
06 · Questions

Frequently asked questions

What is stage rotation for?

The controller alternates the order in which the stages switch on, so the same elements do not always run first. It comes on top of SCR modulation from 0 to 100%.

Can the elements be replaced without changing the boiler?

Yes. Thermo 2000 uses replaceable Incoloy immersion elements. Electrical and mechanical components are covered for 2 years (parts and accessories) and the tank for 10 years (limited warranty, closed-loop heating).

What current does it draw on 480 V?

129.9 A on 480 V three-phase, 60 Hz, according to Thermo 2000.

Can it supply hot-water unit heaters?

Yes, it can supply a unit heater loop; its setpoint adjusts from 50 °F to 200 °F. We check the water temperature your units require before setting up the boiler.

Can you install it?

Yes. We deliver and set the boiler in place, connect the 2 1/2 in loop and the 480 V supply, mount the outdoor sensor and commission it.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 480 V VoltMax SCR 108, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.