THERMO 2000 VoltMax SCR VOLTSCR48075P3 Commercial Electric Boiler | 75 kW - 480V 3 Phase

In stock

Thermo 2000’s VoltMax SCR 75 is a 75 kW commercial electric boiler on 480 V three-phase that supplies, among other things, the radiant floors of workshops, garages and commercial spaces.

Model numberVOLTSCR48075P3

90.2 Acurrent on 480 V three-phase
255,900 BTU/hfor 75 kW
Outdoor sensorincluded, water set to the weather
480 V · three-phaseSCR modulation 0-100%Stage rotation
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberVOLTSCR48075P3
ManufacturerThermo 2000
Manufacturer designationVOLTMAX SCR 75-480-3 PH
Output75 kW
Output in BTU/h255,900 BTU/h
Power supply480 V, three-phase, 60 Hz (90.2 A)
Weight310 lb (141 kg)

75 kW on 480 V to heat workshops, garages and radiant floors

Who the 480 V VoltMax SCR 75 is for

The VoltMax SCR 75 is a commercial electric boiler from Thermo 2000: 75 kW, or 255,900 BTU/h, on 480 V three-phase (manufacturer designation: VOLTMAX SCR 75-480-3 PH). It heats the water in a closed loop and is aimed at owners of commercial or light industrial buildings that already have a 480 V service.

We often suggest it with a radiant floor in mind. A mechanic’s garage in Longueuil, a woodworking shop in Laval, a showroom on the South Shore: these large spaces with high ceilings heat well through the floor, and the boiler can just as easily supply radiators, the coils of an air handling unit or an indirect water heater.

A commercial radiant floor, set to the weather

A radiant floor does not like sudden swings. The outdoor sensor, supplied with the boiler, lets the Schneider Electric controller adjust water temperature to the weather, over a setpoint range of 50 °F to 200 °F. In mild weather, the water stays lukewarm; in deep cold, it rises.

Output follows the same principle. Solid-state relays (SCR) modulate it from 0 to 100%, on top of the relay stages, and the controller rotates its stages. Thermo 2000 points out that this modulation limits peak power, something many commercial building managers keep an eye on. On 480 V three-phase, the manufacturer lists 90.2 A.

The rest is designed to run without much attention: replaceable Incoloy immersion elements, a backlit screen with alarm codes, an Ethernet port with web page and email alarms, and BACnet IP / MS-TP if the building has a management system.

How we install it

We start with a free on-site estimate. We look at the 480 V service, the panel, the mechanical room and, for a radiant floor, the loop and its zones. You then receive a written quote specifying the boiler and what goes with it, including the circulator and expansion tank, which are not on the list Thermo 2000 supplies.

On site, our crews set the 310 lb boiler in place within its clearances (3 in on the sides and back, 24 in in front, 32 in above), connect the piping to the 1 1/2 in NPT connections, and wire the 480 V supply and the outdoor sensor. We fill and purge the loop, then set the temperature curve with you.

Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in Montreal for more than fifteen years, with RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.

Your workshop, our quote

In Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate. You will receive a written quote, and financing is available.

01 · What it is for

Radiant floors and commercial loops on 480 V

A workshop, garage or showroom heated through the floor needs steady, lukewarm water rather than very hot water. The VoltMax SCR 75 sets water temperature from the outdoor sensor and modulates its output from 0 to 100%, on a 480 V three-phase service.

  • Workshops, garages and showrooms with radiant floors
  • Commercial and light industrial buildings on 480 V three-phase
  • Buildings that want to limit peak power draw
  • Replacing a 480 V commercial electric boiler
Gradual ramp-upSolid-state relays (SCR) modulate output from 0 to 100%; according to Thermo 2000, this limits peak power.
Outdoor resetThe supplied sensor adjusts water temperature to the weather, an asset for a radiant floor.
Replaceable Incoloy elementsImmersion elements that can be replaced, and stage rotation handled by the controller.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerThermo 2000
SeriesVoltMax SCR
Manufacturer designationVOLTMAX SCR 75-480-3 PH
TypeCommercial electric hot-water boiler, vertical design
Output75 kW
Output in BTU/h255,900 BTU/h
Power supply480 VAC, 60 Hz, three-phase
Current90.2 A
ModulationSCR 0 to 100% (solid-state relays) plus relay stages
ConfigurationA (22.5 to 90 kW models)
Water volume11 US gal (41.6 L)
Water connections1 1/2 in male NPT, 4 side connections
Relief valve and drain3/4 in female NPT
Setpoint range50 °F to 200 °F (10 °C to 93 °C)
ControllerSchneider Electric, 3 in backlit LCD, alarm codes, French or English, °C or °F
CommunicationBACnet IP / MS-TP; Ethernet port with web page and email alarms
External control0-10 Vdc signal (setpoint and output)
FunctionsOutdoor reset, stage rotation, pump contact with or without domestic hot water priority, second setpoint for an indirect water heater
Outdoor sensorIncluded
Heating elementsImmersion type, Incoloy, replaceable
ClearancesSides 3 in, back 3 in, front 24 in, top 32 in, floor 0
Weight310 lb (141 kg)
Manufacturer warrantyThermo 2000: 10 years on the tank (limited warranty, closed-loop heating); 2 years on electrical and mechanical components (parts and accessories)
StandardsCSA C22.2 No. 165-92, UL 834, CSA B-51-14, CRN, ASME Section IV (H)
Model numberVOLTSCR48075P3
03 · Before installing

What to know before installing

  • 480 V three-phase, 60 Hz power supply, 90.2 A according to Thermo 2000: panel capacity is checked before the quote.
  • The circulator and expansion tank are not on the list Thermo 2000 supplies: they are added to the quote to suit the loop.
  • Clearances: 3 in on the sides and back, 24 in in front, 32 in above.
  • 1 1/2 in male NPT water connections; 3/4 in female NPT relief valve and drain.
  • Thermo 2000 warranty: 10 years on the tank (limited warranty, closed-loop heating), 2 years on electrical and mechanical components.
In the box
  • Schneider Electric controller
  • Outdoor temperature sensor
  • ON/OFF control switch
  • Control and power fuses and breakers
  • SCR relays
  • Two limit controls, automatic and manual reset
  • Factory-installed relief valve
  • Drain valve
  • Low-water cut-off (standard above 60 kW)
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric boilers
See all
Same brand
THERMO 2000
See all
06 · Questions

Frequently asked questions

Is it suitable for a radiant floor?

Yes, that is one of the uses of a hot-water boiler like this one. The setpoint adjusts from 50 °F to 200 °F and the outdoor sensor sets water temperature to the weather. We set the curve for your floor at commissioning.

Why does SCR modulation matter in a commercial building?

The boiler draws only the power it needs instead of switching its elements on in blocks. Thermo 2000 states that 0 to 100% modulation limits peak power.

What current does it draw on 480 V?

90.2 A on 480 V three-phase, 60 Hz, according to Thermo 2000. We check it at the panel during the free estimate.

What happens if a heating element fails?

The Incoloy immersion elements are replaceable according to Thermo 2000: you change the element, not the boiler. Electrical and mechanical components carry a 2-year manufacturer warranty (parts and accessories).

Can you install it?

Yes. We set the boiler in place, connect it to the floor or emitter loop and the 480 V supply, mount the outdoor sensor, then fill, purge and set up the controller.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 480 V VoltMax SCR 75, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.