THERMO 2000 VoltMax SCR VOLTSCR480132P3 Commercial Electric Boiler | 132 kW - 480V 3 Phase

In stock

Thermo 2000’s VoltMax SCR 132 puts 132 kW on 480 V three-phase to work for large commercial and industrial buildings, drawing only the power the loop asks for.

Model numberVOLTSCR480132P3

132 kW450,384 BTU/h
158.8 Aon 480 V three-phase
0 to 100%SCR modulation, limited peak
480 V · three-phaseSCR modulation 0-100%Configuration B
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberVOLTSCR480132P3
ManufacturerThermo 2000
Manufacturer designationVOLTMAX SCR 132-480-3 PH
Output132 kW (450,384 BTU/h)
Power supply480 V, three-phase, 60 Hz
Current158.8 A
Working pressure125 psi (862 kPa), standard

132 kW on 480 V for large buildings, called on only as needed

An electric boiler for heavy heating loads

The VoltMax SCR 132 (manufacturer designation: VOLTMAX SCR 132-480-3 PH) is a commercial electric boiler from Thermo 2000: 132 kW, or 450,384 BTU/h, on 480 V three-phase. It belongs to the series’ configuration B and heats the water in a closed loop, whether it serves unit heaters, a radiant floor, radiators, the coils of air handling units or an indirect water heater.

It is aimed at large buildings: a vehicle service garage with a radiant floor in Laval, a neighbourhood shopping centre on the South Shore, an industrial building on the North Shore. In the 480 V VoltMax SCR range we offer, from 30 to 180 kW, it is a mid-range size: the right choice always comes from a heat-loss calculation.

Output is a matter of metering

At this size, the way the boiler draws its power matters as much as its capacity. Thermo 2000 lists 158.8 A on 480 V three-phase. Rather than switching its elements on in blocks, the VoltMax SCR modulates its output from 0 to 100% through solid-state relays (SCR), on top of its relay stages, and rotates those stages. The manufacturer points out that this modulation limits peak power.

The boiler can also let the building decide. A 0-10 Vdc signal imposes the setpoint or output, and BACnet IP or MS-TP communication lets the management system read its status. Without a central system, its Schneider Electric controller relies on the included outdoor sensor, schedules and a setpoint from 50 °F to 200 °F.

On the hydronic side, the 550 lb vertical cabinet holds 30 US gal of water, connects through four 2 1/2 in male NPT side connections and carries a maximum working pressure of 125 psi (862 kPa) as standard. The Incoloy immersion elements are replaceable.

A job run by AirGreen

We start with a free on-site estimate: electrical service and distribution, mechanical room, loop, emitters, access. The written quote that follows specifies the boiler and what goes with it, including the circulator and expansion tank, which Thermo 2000 does not supply.

Our crews deliver and set the boiler in place within its clearances (24 in in front, 32 in above, 3 in on the sides and back), connect the loop and the 480 V supply, mount the outdoor sensor, fill and purge the circuit, then set up the controller, with the building’s integrator when there is one.

Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.

Let’s talk about your project

In Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: the quote is in writing, and financing is available.

01 · What it is for

A large heating load, called on as needed

At 132 kW, the way the boiler draws its power matters as much as its capacity. The VoltMax SCR 132 modulates from 0 to 100% through solid-state relays and rotates its stages, heating large 480 V buildings without switching on its full output at once.

  • Large commercial and industrial buildings on 480 V three-phase
  • Service garages and warehouses with radiant floors or hot-water unit heaters
  • Institutional buildings whose air handling units have hot-water coils
  • Replacing a high-capacity commercial electric boiler
Limited peak powerThermo 2000 states that SCR modulation from 0 to 100% limits peak power.
Controllable by the building0-10 Vdc signal for setpoint and output, BACnet IP / MS-TP, web page and email alarms.
Format B30 US gal of water, 2 1/2 in male NPT connections and a standard working pressure of 125 psi (862 kPa).
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerThermo 2000
SeriesVoltMax SCR
Manufacturer designationVOLTMAX SCR 132-480-3 PH
TypeCommercial electric hot-water boiler, vertical design
Output132 kW
Output in BTU/h450,384 BTU/h
Power supply480 VAC, 60 Hz, three-phase
Current158.8 A
ModulationSCR 0 to 100% (solid-state relays) plus relay stages
ConfigurationB (99 to 180 kW models)
Water volume30 US gal (113.5 L)
Water connections2 1/2 in male NPT, 4 side connections
Relief valve and drain3/4 in female NPT
Max. working pressure125 psi (862 kPa), standard
Setpoint range50 °F to 200 °F (10 °C to 93 °C)
ControllerSchneider Electric, 3 in backlit LCD, alarm codes, French or English, °C or °F
CommunicationBACnet IP / MS-TP; Ethernet port with web page and email alarms
External control0-10 Vdc signal (setpoint and output)
FunctionsOutdoor reset, stage rotation, pump contact with or without domestic hot water priority, second setpoint for an indirect water heater
Outdoor sensorIncluded
Heating elementsImmersion type, Incoloy, replaceable
ClearancesSides 3 in, back 3 in, front 24 in, top 32 in, floor 0
Weight550 lb (250 kg)
Manufacturer warrantyThermo 2000: 10 years on the tank (limited warranty, closed-loop heating); 2 years on electrical and mechanical components (parts and accessories)
StandardsCSA C22.2 No. 165-92, UL 834, CSA B-51-14, CRN, ASME Section IV (H)
Model numberVOLTSCR480132P3
03 · Before installing

What to know before installing

  • 480 V three-phase, 60 Hz, 158.8 A according to Thermo 2000: the building’s electrical service and distribution are checked before the quote.
  • The right size is chosen from the building’s heat-loss calculation; on 480 V, we offer the VoltMax SCR from 30 to 180 kW.
  • 550 lb (250 kg) boiler: delivery and handling have to be planned.
  • The circulator and expansion tank are not supplied by Thermo 2000: they are added to the quote.
  • Clearances: 24 in in front, 32 in above, 3 in on the sides and back.
In the box
  • Schneider Electric controller
  • Outdoor temperature sensor
  • ON/OFF control switch
  • Control and power fuses and breakers
  • SCR relays
  • Two limit controls, automatic and manual reset
  • Factory-installed relief valve
  • Drain valve
  • Low-water cut-off (standard above 60 kW)
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric boilers
See all
Same brand
THERMO 2000
See all
06 · Questions

Frequently asked questions

Why does modulation matter at this output?

Because 132 kW drawn all at once weighs heavily on the electrical service. The VoltMax SCR 132 adjusts its output from 0 to 100% through solid-state relays; according to Thermo 2000, this limits peak power.

How do we know 132 kW is the right size?

Through a heat-loss calculation for the building. On 480 V, we offer the series from 30 to 180 kW, and we recommend the size that matches the calculation.

What current does it draw on 480 V?

158.8 A on 480 V three-phase, 60 Hz, according to Thermo 2000.

Can the building system control it?

Yes: a 0-10 Vdc signal for setpoint or output, or BACnet IP or MS-TP communication.

What does the warranty cover?

Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years (parts and accessories).

Can you install it, electrical work included?

Yes. Our RBQ licence covers electrical work: we connect the boiler to the 480 V supply, the loop and the outdoor sensor, then commission it.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 480 V VoltMax SCR 132, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.