Thermo 2000’s VoltMax SCR 165 is a 165 kW commercial electric boiler on 480 V three-phase, backed by an engineering specification and CSA, UL and ASME certifications.
Model numberVOLTSCR480165P3
514 316-2973 · sales@airgreen.ca
Quick facts
165 kW on 480 V, with the documentation a commercial project calls for
The VoltMax SCR 165 at a glance
The VoltMax SCR 165 is Thermo 2000’s 165 kW commercial electric boiler, here in its 480 V three-phase version. The manufacturer rates it at 562,980 BTU/h. It heats the water in a closed loop that feeds radiators, hot-water baseboards, a radiant floor or hydro-air coils, and it can serve an indirect water heater through a second setpoint.
It is aimed mainly at engineer-designed projects: a new industrial building, a commercial expansion, the replacement of a commercial boiler in an existing building. In those files, the boiler first has to pass the drawing review.
What the engineer and the inspector will find
Thermo 2000 publishes an engineering specification, an installation manual and a brochure for the VoltMax, gathered in the Documents section. The specification lists CSA C22.2 No. 165-92 and UL 834, a CSA B-51-14 tank, CRN registration and the ASME Section IV "H" stamp. For safety, the boiler comes with two limit controls with automatic and manual reset, a factory-installed relief valve and, since it exceeds 60 kW, a standard low-water cutoff.
For the control sequence, the Schneider Electric controller combines SCR modulation from 0 to 100% with rotation of the relay stages. It accepts a 0-10 Vdc signal for setpoint and output, communicates over BACnet IP and MS-TP, and adjusts the water temperature with the supplied outdoor sensor.
On site, in Quebec
On 480 V three-phase, the VoltMax SCR 165 draws 198.5 A; sizing the circuit is up to the engineer or the master electrician. In an industrial building in Laval, for example, the vertical boiler fits with 3 in of clearance on the sides and back, 24 in in front and 32 in above. Its four 2 1/2 in male NPT side connections, its 30 US gal of water and its 50 °F to 200 °F setpoint go straight onto the drawings. For handling, count on 550 lb (250 kg).
Our role on site
AirGreen installs the boiler to the engineer’s drawings and specification. After a free on-site estimate, we provide a written quote that specifies the circulating pump and the expansion tank, which are not on Thermo 2000’s list of supplied items. On site, our crews set the boiler in place, connect the piping and the 480 V circuit, fill and purge the loop, then commission the controller and the outdoor sensor.
A family business established in Montreal for more than fifteen years, we hold RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work. Thermo 2000, for its part, warrants the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years.
Let’s prepare your project
Engineer, contractor or owner in Laval, Montreal, Longueuil, on the North Shore or the South Shore: ask for a free estimate and a written quote. Financing is available.
A 165 kW boiler to write into a 480 V project specification
For the engineer or contractor preparing a project, the VoltMax SCR 165 comes with an engineering specification, an installation manual and published certifications. This version runs on 480 V three-phase.
- New or replacement projects designed by a building mechanical engineer
- Industrial and commercial buildings on 480 V three-phase power
- Hot-water heating loops: radiators, baseboards, radiant floors, hydro-air
- Projects that call for 0-10 Vdc signal control or a BACnet link
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- 480 V three-phase, 60 Hz power supply: 198.5 A. Overcurrent protection and conductor sizes are determined by the engineer or the master electrician.
- Published clearances to carry onto the mechanical room drawings: 3 in on the sides and back, 24 in in front, 32 in above, none underneath.
- The circulating pump and expansion tank are not on Thermo 2000’s list of supplied items: they must be included in the specification.
- Weight of 550 lb (250 kg) to account for in handling and for the mechanical room slab.
- Schneider Electric controller with backlit display
- Outdoor temperature sensor
- On/off control switch
- Control and power fuses and breakers
- SCR relays
- Two limit controls, automatic and manual reset
- Factory-installed relief valve
- Drain valve
- Low-water cutoff
Manufacturer documents
Explore the range
Electric boilersSee allSame brand
THERMO 2000See all
Frequently asked questions
Which technical documents are available?
Thermo 2000 publishes an engineering specification, an installation manual and a French brochure, gathered in the Documents section of this page.
Which standards does the boiler meet?
According to the manufacturer’s specification: CSA C22.2 No. 165-92 and UL 834 (CSA mark for Canada and the United States), CSA B-51-14 tank, CRN registration and ASME Section IV "H" stamp.
Is the low-water cutoff included?
Yes. Thermo 2000 supplies it as standard on models above 60 kW, so on this 165 kW boiler, along with two limit controls with automatic and manual reset and a factory-installed relief valve.
Can it be controlled from a PLC or a management system?
Yes: by a 0-10 Vdc signal that sets the setpoint and the output, or over BACnet IP / MS-TP. Thermo 2000 does not mention Modbus.
Do you work with the project engineer?
Yes. We install to the engineer’s drawings and specification, connect the piping and the 480 V circuit, then commission the controller and the outdoor sensor.
A 165 kW, 480 V VoltMax SCR, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.