THERMO 2000 VoltMax SCR VOLTSCR600108P3 Commercial Electric Boiler | 108 kW - 600V 3 Phase
Thermo 2000’s VoltMax SCR 108 heats the radiator loops of sizeable buildings on 600 V three-phase, with water set to the outdoor temperature, up to 200 °F.
Model numberVOLTSCR600108P3
514 316-2973 · sales@airgreen.ca
Quick facts
108 kW on 600 V for radiator buildings, set to the outdoor temperature
Buildings that still heat with radiators
Many office buildings in downtown Montreal and rental buildings in Laval still heat their spaces with hot-water radiators. When the electric boiler reaches the end of its life, it has to be replaced without touching the distribution. Thermo 2000’s VoltMax SCR 108, on 600 V three-phase (manufacturer designation: VOLTMAX SCR 108-600-3 PH), is a serious option for these sizeable buildings.
It delivers 108 kW, or 368,496 BTU/h, and belongs to the series’ configuration B: 30 US gal of water, four 2 1/2 in male NPT side connections and a maximum working pressure of 125 psi (862 kPa) as standard.
Water at the right temperature, from autumn to deep cold
A radiator does not need the same water in October as in January. The included outdoor sensor lets the Schneider Electric controller follow a curve: the water stays moderate in mild weather and rises as the cold sets in, over a setpoint range of 50 °F to 200 °F (10 °C to 93 °C). Occupants gain comfort, and the boiler does not heat more than it needs to.
The controller also follows schedules, useful in an office building that is empty at night and on weekends. It can handle a second setpoint for an indirect water heater, communicate over BACnet IP or MS-TP and send its alarms by email through its Ethernet port.
On the electrical side, Thermo 2000 lists 103.9 A on 600 V three-phase. Output is modulated from 0 to 100% through solid-state relays, on top of the relay stages, which limits peak power according to the manufacturer.
The replacement, done by AirGreen
In an older building, the on-site estimate counts double: we check the 600 V service, the mechanical room, the condition of the radiators and the loop, and the route to deliver a 550 lb boiler. The estimate is free, and the written quote specifies the parts to add, including the circulator and expansion tank, which Thermo 2000 does not supply.
On installation day, our crews remove the old boiler, install the VoltMax SCR 108 with its clearances (24 in in front, 32 in above, 3 in on the sides and back), connect it to the existing loop and the 600 V supply, mount the outdoor sensor, then fill and purge the circuit. We then set the curve and the schedules with you.
Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in Montreal for more than fifteen years; we hold RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.
Let’s replace your boiler
In Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: the quote is in writing, and financing is available.
Radiators at the right temperature, set to the weather
An older building heated by radiators needs hotter water in deep cold and much less in autumn. The 600 V VoltMax SCR 108 adjusts that temperature through its outdoor sensor, over a setpoint range of 50 °F to 200 °F, and follows occupancy schedules.
- Older office and rental buildings heated by radiators
- Institutional buildings on 600 V three-phase
- Loops that also feed an indirect water heater
- Replacing a 600 V commercial electric boiler
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- 600 V three-phase, 60 Hz, 103.9 A: the service and panel are checked at the estimate.
- 550 lb (250 kg) boiler: access to the mechanical room of an older building is checked before delivery.
- We assess the condition of the radiators and the existing loop before quoting.
- Circulator and expansion tank: not supplied by Thermo 2000, they are included in our quote.
- Clearances: 3 in on the sides and back, 24 in in front, 32 in above.
- Schneider Electric controller
- Outdoor temperature sensor
- ON/OFF control switch
- Control and power fuses and breakers
- SCR relays
- Two limit controls, automatic and manual reset
- Factory-installed relief valve
- Drain valve
- Low-water cut-off (standard above 60 kW)
Manufacturer documents
Explore the range
Electric boilersSee allSame brand
THERMO 2000See all
Frequently asked questions
Is the boiler suitable for radiators?
Yes. Its water setpoint adjusts from 50 °F to 200 °F (10 °C to 93 °C) and the included outdoor sensor sets the temperature to the weather. We set the curve for your radiators.
Can the temperature be lowered at night in the offices?
Yes, the controller handles schedules. We program them at commissioning to match the building’s occupancy.
What current does it draw on 600 V?
103.9 A on 600 V three-phase, 60 Hz, according to Thermo 2000.
What is the warranty?
Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years (parts and accessories).
Can you replace our old boiler?
Yes. We remove the old unit, install the VoltMax SCR 108, connect it to the existing loop and the 600 V supply, then fill, purge and set up the system.
A 600 V VoltMax SCR 108, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.