THERMO 2000 VoltMax SCR VOLTSCR60090P3 Commercial Electric Boiler | 90 kW - 600V 3 Phase

In stock

Thermo 2000’s VoltMax SCR 90 delivers 90 kW on 600 V three-phase and accepts a setpoint or output imposed by a 0-10 Vdc signal, so it follows the building’s control sequence.

Model numberVOLTSCR60090P3

90 kW307,080 BTU/h
86.6 Aon 600 V three-phase
0-10 Vdcexternal setpoint and output
600 V · three-phase0-10 Vdc controlBACnet IP / MS-TP
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberVOLTSCR60090P3
ManufacturerThermo 2000
Manufacturer designationVOLTMAX SCR 90-600-3 PH
Output90 kW
Power supply600 V, three-phase, 60 Hz
Current86.6 A
External control0-10 Vdc, BACnet IP / MS-TP

90 kW on 600 V, run by the building’s system or by its own controller

A commercial boiler that fits into a control sequence

In a clinic in Laval or a shopping centre on the South Shore, heating often goes through the hot-water coils of the air handling units, and a management system decides when to heat and to what temperature. Thermo 2000’s VoltMax SCR 90, on 600 V three-phase (manufacturer designation: VOLTMAX SCR 90-600-3 PH), suits that role well: it can take its orders from outside.

It delivers 90 kW, or 307,080 BTU/h, and heats a closed loop that can serve coils, radiators, a radiant floor or an indirect water heater. Thermo 2000 designs it for commercial and institutional buildings.

Two ways to control it, and a third without a central system

First way: a 0-10 Vdc signal. The building system imposes the water temperature setpoint or the boiler’s output. Second way: BACnet IP or MS-TP communication, which also lets the system read status and alarms. And if the building has no central system, the Schneider Electric controller does the job on its own, with the included outdoor sensor, schedules and a setpoint adjustable from 50 °F to 200 °F.

In every case, output is modulated from 0 to 100% through solid-state relays (SCR), on top of the relay stages, and the controller rotates its stages. Thermo 2000 states that this modulation limits peak power. On 600 V three-phase, the boiler draws 86.6 A.

Physically, it is the largest configuration A model: a 310 lb vertical cabinet holding 11 US gal of water, with 3 in of clearance on the sides and back, 24 in in front and 32 in above.

Installation, coordinated by AirGreen

The free on-site estimate lets us check the 600 V service, the loop and the planned sequence. We then give you a written quote specifying the boiler and the components to add, including the circulator and expansion tank, which Thermo 2000 does not supply.

Our crews install the boiler, connect the piping to the 1 1/2 in NPT side connections, wire the 600 V supply and the control wiring, then fill and purge the loop. Commissioning is done with the engineer or the management system integrator when the building has one.

Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in Montreal for more than fifteen years and holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.

Your commercial project

In Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: the quote is in writing, and financing is available.

01 · What it is for

Hot water for coils and the building’s sequence

In a building whose air handling units have hot-water coils, the boiler has to respond to the control sequence. The 600 V VoltMax SCR 90 takes its setpoint or output from a 0-10 Vdc signal or over BACnet, and can also run on its own controller.

  • Buildings with hot-water coils in their air handling units
  • Clinics, shopping centres and office buildings on 600 V three-phase
  • Projects where an engineer defines the heating control sequence
  • Replacing a 600 V commercial electric boiler
0-10 Vdc controlAn external signal sets the boiler’s temperature setpoint or output.
BACnet IP or MS-TPThe boiler joins the building management system, with a web page and email alarms on top.
90 kW in a compact formatThe largest configuration A model: 310 lb, 11 US gal of water, vertical design.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerThermo 2000
SeriesVoltMax SCR
Manufacturer designationVOLTMAX SCR 90-600-3 PH
TypeCommercial electric hot-water boiler, vertical design
Output90 kW
Output in BTU/h307,080 BTU/h
Power supply600 VAC, 60 Hz, three-phase
Current86.6 A
ModulationSCR 0 to 100% (solid-state relays) plus relay stages
ConfigurationA (22.5 to 90 kW models)
Water volume11 US gal (41.6 L)
Water connections1 1/2 in male NPT, 4 side connections
Relief valve and drain3/4 in female NPT
Setpoint range50 °F to 200 °F (10 °C to 93 °C)
ControllerSchneider Electric, 3 in backlit LCD, alarm codes, French or English, °C or °F
CommunicationBACnet IP / MS-TP; Ethernet port with web page and email alarms
External control0-10 Vdc signal (setpoint and output)
FunctionsOutdoor reset, stage rotation, pump contact with or without domestic hot water priority, second setpoint for an indirect water heater
Outdoor sensorIncluded
Heating elementsImmersion type, Incoloy, replaceable
ClearancesSides 3 in, back 3 in, front 24 in, top 32 in, floor 0
Weight310 lb (141 kg)
Manufacturer warrantyThermo 2000: 10 years on the tank (limited warranty, closed-loop heating); 2 years on electrical and mechanical components (parts and accessories)
StandardsCSA C22.2 No. 165-92, UL 834, CSA B-51-14, CRN, ASME Section IV (H)
Model numberVOLTSCR60090P3
03 · Before installing

What to know before installing

  • 600 V three-phase, 60 Hz power supply: 86.6 A according to Thermo 2000. We check the service before quoting.
  • The control sequence (0-10 Vdc signal or BACnet) is defined with the building’s engineer or integrator before commissioning.
  • The circulator and expansion tank are not among the components Thermo 2000 supplies.
  • Clearances: 3 in on the sides and back, 24 in in front, 32 in above, 0 at the floor.
  • Thermo 2000 warranty: 10 years on the tank (limited warranty, closed-loop heating), 2 years on electrical and mechanical components.
In the box
  • Schneider Electric controller
  • Outdoor temperature sensor
  • ON/OFF control switch
  • Control and power fuses and breakers
  • SCR relays
  • Two limit controls, automatic and manual reset
  • Factory-installed relief valve
  • Drain valve
  • Low-water cut-off (standard above 60 kW)
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric boilers
See all
Same brand
THERMO 2000
See all
06 · Questions

Frequently asked questions

Can the building system control the boiler?

Yes, in two ways: a 0-10 Vdc signal that sets the setpoint or output, or BACnet IP or MS-TP communication. We set up the boiler according to the sequence specified by the engineer or integrator.

Is it suitable for the hot-water coils of an air handling unit?

Yes, that is one of the uses of a hot-water boiler like the VoltMax SCR. Its setpoint adjusts from 50 °F to 200 °F, and the loop is sized for the coils in place.

Can it run without a management system?

Yes. Its Schneider Electric controller handles the setpoint, outdoor reset (sensor included) and schedules on its own.

What current does it draw on 600 V?

86.6 A on 600 V three-phase, 60 Hz, according to Thermo 2000.

Can you install it?

Yes. We install and connect the boiler, wire the 600 V supply and the control wiring, then commission it, with the integrator where applicable.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 600 V VoltMax SCR 90, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.