THERMO 2000 VoltMax SCR VOLTSCR60075P3 Commercial Electric Boiler | 75 kW - 600V 3 Phase

In stock

Thermo 2000’s VoltMax SCR 75 is a 75 kW commercial electric boiler on 600 V three-phase that the building manager can follow remotely, through a web page and email alarms.

Model numberVOLTSCR60075P3

75 kW255,900 BTU/h
72.2 Aon 600 V three-phase
Ethernetweb page and email alarms
600 V · three-phaseEmail alarmsOn-screen alarm codes
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberVOLTSCR60075P3
ManufacturerThermo 2000
SeriesVoltMax SCR
Manufacturer designationVOLTMAX SCR 75-600-3 PH
Output75 kW (255,900 BTU/h)
Power supply600 V, three-phase, 60 Hz
Current72.2 A

A 75 kW, 600 V boiler the building manager can monitor remotely

For buildings where nobody watches the mechanical room

Many commercial and institutional buildings run without technical staff on site. A church on the North Shore heated all week for a few hours of use, a community hall in Laval, a small office building managed by an outside firm: when the boiler stops, people often find out from the occupants. Thermo 2000’s VoltMax SCR 75 has what it takes to avoid that kind of surprise.

It is a 75 kW commercial electric boiler, or 255,900 BTU/h, here on 600 V three-phase (manufacturer designation: VOLTMAX SCR 75-600-3 PH). It heats a closed loop that serves radiators, a radiant floor, the coils of an air handling unit or an indirect water heater.

Remote monitoring built into the controller

The Schneider Electric controller includes an Ethernet port. Once connected to the building network, it gives access to a web page and sends alarms by email: the manager is notified without having to travel. On site, the 3 in backlit LCD shows alarm codes in French or English, which helps the technician target the repair.

For a portfolio that already has a central management system, the boiler communicates over BACnet IP or MS-TP and accepts an external 0-10 Vdc command. Without a central system, it sets water temperature itself using the included outdoor sensor and its schedules.

On the electrical side, Thermo 2000 lists 72.2 A on 600 V three-phase. Output is modulated from 0 to 100% through solid-state relays, on top of the relay stages, which limits peak power according to the manufacturer. Quiet, clean and low-maintenance, again according to Thermo 2000, it uses replaceable Incoloy immersion elements.

Installation, done by AirGreen

After a free on-site estimate, we give you a written quote. It takes into account the 600 V service, the existing loop and what Thermo 2000 does not supply, such as the circulator and expansion tank. If you want email alarms, we also plan the connection of the Ethernet port to the building network.

Our crews then set the 310 lb boiler in place (24 in clear in front, 32 in above, 3 in on the sides and back), connect the 1 1/2 in NPT piping and the 600 V supply, mount the outdoor sensor, then fill and purge the loop. Commissioning includes setting the setpoint, the outdoor reset curve and the alarm recipients.

Thermo 2000’s warranty covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen, a family business established in Montreal for more than fifteen years, holds RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.

Let’s talk about your buildings

Whether your buildings are in Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for a free estimate: the quote is in writing and financing is available.

01 · What it is for

A 75 kW boiler you can watch without being on site

A church, a community hall or an office building often has nobody in the mechanical room. The 600 V VoltMax SCR 75 heats the hot-water loop and notifies the manager by email when an alarm occurs.

  • Churches, community halls and buildings with variable occupancy on 600 V
  • Property portfolios managed remotely by one manager
  • Office buildings heated by radiators or hot-water coils
  • Replacing a commercial electric boiler on 600 V three-phase
Web page and email alarmsThe controller’s Ethernet port gives access to a web page and sends alarms by email.
On-screen diagnostics3 in backlit LCD with alarm codes, in French or English.
Low maintenanceThermo 2000 describes it as quiet, clean and low-maintenance; its Incoloy elements are replaceable.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerThermo 2000
SeriesVoltMax SCR
Manufacturer designationVOLTMAX SCR 75-600-3 PH
TypeCommercial electric hot-water boiler, vertical design
Output75 kW
Output in BTU/h255,900 BTU/h
Power supply600 VAC, 60 Hz, three-phase
Current72.2 A
ModulationSCR 0 to 100% (solid-state relays) plus relay stages
ConfigurationA (22.5 to 90 kW models)
Water volume11 US gal (41.6 L)
Water connections1 1/2 in male NPT, 4 side connections
Relief valve and drain3/4 in female NPT
Setpoint range50 °F to 200 °F (10 °C to 93 °C)
ControllerSchneider Electric, 3 in backlit LCD, alarm codes, French or English, °C or °F
CommunicationBACnet IP / MS-TP; Ethernet port with web page and email alarms
External control0-10 Vdc signal (setpoint and output)
FunctionsOutdoor reset, stage rotation, pump contact with or without domestic hot water priority, second setpoint for an indirect water heater
Outdoor sensorIncluded
Heating elementsImmersion type, Incoloy, replaceable
ClearancesSides 3 in, back 3 in, front 24 in, top 32 in, floor 0
Weight310 lb (141 kg)
Manufacturer warrantyThermo 2000: 10 years on the tank (limited warranty, closed-loop heating); 2 years on electrical and mechanical components (parts and accessories)
StandardsCSA C22.2 No. 165-92, UL 834, CSA B-51-14, CRN, ASME Section IV (H)
Model numberVOLTSCR60075P3
03 · Before installing

What to know before installing

  • 600 V three-phase, 60 Hz, 72.2 A: we check the building’s service and panel before quoting.
  • Email alarms require connecting the Ethernet port to the building network: plan network access near the mechanical room.
  • Circulator and expansion tank not supplied by Thermo 2000: they are included in our quote.
  • The boiler weighs 310 lb (141 kg) and needs 24 in of clearance in front, 32 in above and 3 in on the sides and back.
  • Manufacturer warranty: tank 10 years (limited warranty, closed-loop heating), electrical and mechanical components 2 years.
In the box
  • Schneider Electric controller
  • Outdoor temperature sensor
  • ON/OFF control switch
  • Control and power fuses and breakers
  • SCR relays
  • Two limit controls, automatic and manual reset
  • Factory-installed relief valve
  • Drain valve
  • Low-water cut-off (standard above 60 kW)
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric boilers
See all
Same brand
THERMO 2000
See all
06 · Questions

Frequently asked questions

Can we be warned of a fault without being on site?

Yes. The controller’s Ethernet port sends alarms by email and gives access to a web page. The boiler has to be connected to the building network; we plan for it at installation.

What if the building already has a management system?

The controller communicates over BACnet IP or MS-TP and accepts a 0-10 Vdc signal for setpoint and output. We coordinate the connection with the firm that manages the system.

What current does it draw on 600 V?

72.2 A on 600 V three-phase, 60 Hz, according to Thermo 2000.

What maintenance should we expect?

Thermo 2000 presents it as quiet, clean and low-maintenance. Its Incoloy immersion elements are replaceable, and its alarm codes point the technician in the right direction when there is a fault.

Can you install it?

Yes. We set the boiler in place, connect it to the loop and the 600 V supply, mount the outdoor sensor, connect the Ethernet port if you want email alarms, then commission it.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 600 V VoltMax SCR 75, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.