THERMO 2000 VoltMax SCR VOLTSCR60099P3 Commercial Electric Boiler | 99 kW - 600V 3 Phase
Thermo 2000’s VoltMax SCR 99 is a 99 kW commercial electric boiler on 600 V three-phase, with a CSA B-51-14 tank, CRN registration and the ASME Section IV "H" stamp.
Model numberVOLTSCR60099P3
514 316-2973 · sales@airgreen.ca
Quick facts
99 kW on 600 V, with the certifications an institutional project checks
For buildings where everything goes through a specification
In a school in Montreal, a seniors’ residence in Longueuil or a public building on the South Shore, choosing a boiler is rarely up to the owner alone. The engineer writes a specification, the manager checks compliance, the inspector looks at the nameplates. Thermo 2000’s VoltMax SCR 99, on 600 V three-phase (manufacturer designation: VOLTMAX SCR 99-600-3 PH), fits well into that framework, and the manufacturer also publishes an engineering specification for the series.
It is a 99 kW commercial electric boiler, or 337,788 BTU/h, in the series’ format B: 30 US gal of water, four 2 1/2 in male NPT side connections, 550 lb. It heats a closed loop of radiators, a radiant floor, hot-water coils or an indirect water heater.
Certifications and working pressure
Thermo 2000 lists the CSA C22.2 No. 165-92 and UL 834 standards for this model, with the CSA mark for Canada and the United States. The tank complies with CSA B-51-14 and carries a CRN registration as well as the ASME Section IV "H" stamp. The published maximum working pressure is 125 psi (862 kPa) as standard.
On the electrical side, the boiler draws 95.3 A on 600 V three-phase, a common voltage in Québec institutional buildings. It modulates its output from 0 to 100% through solid-state relays, on top of its relay stages, and Thermo 2000 states that this modulation limits peak power.
For operation, the Schneider Electric controller handles outdoor reset (sensor included), schedules, a second setpoint for an indirect water heater and BACnet IP or MS-TP communication. Its alarms show on screen and go out by email through the Ethernet port.
What our installation includes
We start with a free on-site estimate, then provide a written quote that follows the engineer’s specification if there is one. It also lists the parts Thermo 2000 does not supply, such as the circulator and expansion tank. The manufacturer’s spec sheet, installation manual and brochure are available in the Documents section of this page.
On site, our crews deliver the 550 lb boiler, set it in place with 24 in clear in front, 32 in above and 3 in on the sides and back, connect the loop in 2 1/2 in, wire the 600 V supply and the outdoor sensor, fill and purge the circuit, then commission it.
Thermo 2000 covers the tank for 10 years (limited warranty, closed-loop heating) and the electrical and mechanical components for 2 years. AirGreen is a family business established in Montreal for more than fifteen years, holding RBQ licence 5645-9605-01 in ventilation, refrigeration and electrical work.
Your institutional project
In Montreal, Laval, Longueuil, on the North Shore or on the South Shore, ask for your free estimate: the quote is in writing, and financing is available.
A well-documented boiler for institutional buildings
Schools, seniors’ residences, healthcare facilities and public buildings often go through an engineer and a specification. The 600 V VoltMax SCR 99 comes with its certifications: CSA mark for Canada and the US, CSA B-51-14 tank, CRN and ASME Section IV.
- Schools, seniors’ residences and public buildings on 600 V three-phase
- Engineer-designed projects built to a specification
- Radiator or hot-water coil loops in multi-storey buildings
- Replacing a 600 V commercial electric boiler
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- 600 V three-phase, 60 Hz power supply, 95.3 A according to Thermo 2000: we check the building’s service before quoting.
- 550 lb (250 kg) boiler: plan the delivery route to the mechanical room.
- Clearances: 3 in on the sides and back, 24 in in front, 32 in above.
- The circulator and expansion tank are not on Thermo 2000’s list of supplied components.
- Limited 10-year warranty on the tank (closed-loop heating) and 2 years on electrical and mechanical components, according to Thermo 2000.
- Schneider Electric controller
- Outdoor temperature sensor
- ON/OFF control switch
- Control and power fuses and breakers
- SCR relays
- Two limit controls, automatic and manual reset
- Factory-installed relief valve
- Drain valve
- Low-water cut-off (standard above 60 kW)
Manufacturer documents
Explore the range
Electric boilersSee allSame brand
THERMO 2000See all
Frequently asked questions
What certifications does the boiler carry?
Thermo 2000 lists CSA C22.2 No. 165-92 and UL 834 (CSA mark for Canada and the United States), a tank compliant with CSA B-51-14, a CRN registration and the ASME Section IV "H" stamp.
What is a CRN?
The Canadian Registration Number (CRN) shows that the design of a pressure vessel has been registered with the provincial authorities. Thermo 2000 lists it for the VoltMax SCR.
What is the working pressure?
125 psi (862 kPa) as standard for configuration B, according to Thermo 2000.
Can you provide the documents to our engineer?
Yes. Thermo 2000’s spec sheet, installation manual and brochure are in the Documents section of this page, and we attach them to the quote when needed.
Can you install it?
Yes. We deliver and install the boiler, connect the loop and the 600 V supply, mount the outdoor sensor and commission it.
A 600 V VoltMax SCR 99, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.