LMAS1: one name, two generations, down to -15 °C.
Fujitsu’s “High SEER” wall unit was sold in two generations under the same name. One letter in the model number, G or H, changes everything: ENERGY STAR certification, the LogisVert amount and even BACnet compatibility. Here is how to tell them apart, and what to pick on R-32.
LMAS1 · R-410A
Launched in 2020, the LMAS1 took over from the RLFW1. Fujitsu called it “High SEER”.
One name, two generations: six facts to find your way.
Facts from Fujitsu sheets, the ENERGY STAR list and the NEEP list. Sources are at the bottom of the page.
Two generations share the LMAS1 name. The G or H in the model number tells them apart.
Only Generation H is ENERGY STAR certified.
The Generation H 9,000 and 12,000 are BACnet and Modbus compatible, according to Fujitsu.
The 18,000 and 24,000 accept up to 50 m of line set and 30 m of height difference.
The 18,000 delivers 21,600 BTU/h at -15 °C, more than its nominal size.
The 24,000 has a wider indoor unit, 1,150 mm.
Generation G or H: the letter that changes everything.
Tap the generation printed on your label (AOUG/ASUG or AOUH/ASUH): the tool shows the certification, the LogisVert amount and the communication options.
Generation G
| Model prefix | AOUG / ASUG |
| ENERGY STAR | no |
| 9,000 · G BTU/h · LogisVert | $0 |
| 12,000 · G BTU/h · LogisVert | $0 |
| BACnet / Modbus | not listed |
| Submittal sheet | effective January 20, 2021 |
Generation H
| Model prefix | AOUH / ASUH |
| ENERGY STAR | yes |
| 9,000 · H BTU/h · LogisVert | $0 |
| 12,000 · H BTU/h · LogisVert | $440 |
| BACnet / Modbus | yes, according to Fujitsu (9,000 and 12,000) |
| On the market | January 2022 (9,000 and 12,000), per ENERGY STAR |
Eight R-410A series, from the coldest floor to the mildest.
Before R-32, Fujitsu wall units ran on R-410A. Each card gives the series’ heating floor; the LMAS1 is highlighted.
Four sizes, and two generations at 9,000 and 12,000.
Tap a size: photo, link to the product sheet, heat at -15 °C when Fujitsu publishes it, efficiency and LogisVert amount.
| Model | Heats down to | Max at -15 °C | SEER2 | HSPF2 | LogisVert | AHRI |
|---|---|---|---|---|---|---|
| LMAS1 9,000 BTU/h (Generation G) | -15 °C | – | – | – | $0 | – |
| LMAS1 9,000 BTU/h (Generation H) | -15 °C | 10,200 BTU/h | 26.5 | 12.6 | $0 | 207615688 |
| LMAS1 12,000 BTU/h (Generation G) | -15 °C | – | – | – | $0 | – |
| LMAS1 12,000 BTU/h (Generation H) | -15 °C | 10,700 BTU/h | 23 | 11.1 | $440 | 207615689 |
| LMAS1 18,000 BTU/h | -15 °C | 21,600 BTU/h | 21.1 | 11.5 | $1,632 | 206913027 |
| LMAS1 24,000 BTU/h | -15 °C | 25,500 BTU/h | 22.5 | 11.4 | $1,884 | 206913028 |
The indoor unit, to scale
Front face drawn to scale, with the 1 m ruler. Dimensions: width × height × depth, according to Fujitsu.
Down to -15 °C, and 21,600 BTU/h for the 18,000.
The bars show the maximum published heat; the red tick, the ENERGY STAR value LogisVert uses; the dotted line, the nominal size. Fujitsu publishes fewer points for its older series: a dash means “not published”.
| Size | 8.3 °C | -8.3 °C | -15 °C |
|---|---|---|---|
| 9,000 · G BTU/h | 15,000 BTU/h | – | – |
| 9,000 · H BTU/h | 15,000 BTU/h | 10,100 BTU/h | 10,200 BTU/h |
| 12,000 · G BTU/h | 19,100 BTU/h | – | – |
| 12,000 · H BTU/h | 19,100 BTU/h | 12,700 BTU/h | 10,700 BTU/h |
| 18,000 BTU/h | 29,000 BTU/h | 23,700 BTU/h | 21,600 BTU/h |
| 24,000 BTU/h | 37,000 BTU/h | 28,700 BTU/h | 25,500 BTU/h |
Operating ranges
Outdoor operating temperatures published by Fujitsu.
What Fujitsu put in it.
Fujitsu lists this series among its retired models. It stays in AirGreen’s catalogue: we confirm availability at quote time, and show you its R-32 successor alongside.
Optional Wi-Fi: a wireless adapter, sold separately, adds app control.
Minimum heat mode: the room stays at 10 °C while you’re away.
Economy mode: the set point adjusts to avoid over-heating or over-cooling.
Apple-catechin filter and ion deodorizing filter, according to Fujitsu.
BACnet and Modbus compatible, according to Fujitsu, which is useful for a building management system.
19 dB(A) at 9,000 and 12,000.
Place each size on the scale of everyday sounds.
| Model | Indoor, quiet speed | Indoor, high speed | Outdoor unit |
|---|---|---|---|
| LMAS1 9,000 BTU/h (Generation G) | 19 dB(A) | 43 dB(A) | 48 dB(A) |
| LMAS1 9,000 BTU/h (Generation H) | 19 dB(A) | 43 dB(A) | 48 dB(A) |
| LMAS1 12,000 BTU/h (Generation G) | 19 dB(A) | 43 dB(A) | 51 dB(A) |
| LMAS1 12,000 BTU/h (Generation H) | 19 dB(A) | 43 dB(A) | 51 dB(A) |
| LMAS1 18,000 BTU/h | 30 dB(A) | 46 dB(A) | 50 dB(A) |
| LMAS1 24,000 BTU/h | 33 dB(A) | 46 dB(A) | 54 dB(A) |
Levels published by Fujitsu, measured in a lab; at home, the room, the furniture and the distance change what you hear. Scale: Government of Québec reference points.
Quiet speed, size by size.
The lowest indoor sound level published by Fujitsu. In red: below a whisper heard a metre away (20 dB).
From 20 to 50 m of line set depending on size.
Drag the sliders to place the outdoor unit: the tool applies Fujitsu’s limits and the refrigerant to add beyond the pre-charge.
| Model | Max length | Max height | Pre-charge | Minimum |
|---|---|---|---|---|
| LMAS1 9,000 BTU/h (Generation G) | 20 m | 15 m | 15 m | 3 m |
| LMAS1 9,000 BTU/h (Generation H) | 20 m | 15 m | 15 m | 3 m |
| LMAS1 12,000 BTU/h (Generation G) | 20 m | 15 m | 15 m | 3 m |
| LMAS1 12,000 BTU/h (Generation H) | 20 m | 15 m | 15 m | 3 m |
| LMAS1 18,000 BTU/h | 50 m | 30 m | 15 m | 5 m |
| LMAS1 24,000 BTU/h | 50 m | 30 m | 20 m | 5 m |
From $0 to $1,884: the generation matters.
R-410A is not excluded by LogisVert: what counts is the ENERGY STAR list and the 12,000 BTU/h minimum size.
| Model | Indicative amount | Calculation |
|---|---|---|
| LMAS1 9,000 BTU/h (Generation G) | $0 | – |
| LMAS1 9,000 BTU/h (Generation H) | $0 | – |
| LMAS1 12,000 BTU/h (Generation G) | $0 | – |
| LMAS1 12,000 BTU/h (Generation H) | $440 | 8,800 BTU/h ÷ 1,000 × $50 = $440 |
| LMAS1 18,000 BTU/h | $1,632 | 13,600 BTU/h ÷ 1,000 × $120 = $1,632 |
| LMAS1 24,000 BTU/h | $1,884 | 15,700 BTU/h ÷ 1,000 × $120 = $1,884 |
Since November 26, 2025, only ENERGY STAR certified heat pumps qualify.
The outdoor unit must be at least 12,000 BTU/h nominal in cooling.
The grant never exceeds the purchase and installation cost, before taxes.
You apply no later than nine months after installation.
July 8, 2027
LogisVert residential participation guide, version 1.10 of September 15, 2026. Indicative amounts, calculated with the ENERGY STAR value at -8 °C (17 °F); only Hydro-Québec confirms the grant, with the AHRI number.
What replaces the LMAS1 today.
Pick a size: the LMAS1 on the left, the R-32 model that replaces it on the right, with the figures from Fujitsu, ENERGY STAR and LogisVert. The better value on each row is in green.
LMAS1 · 9,000 · G vs Altair 700 · 9,000
| LMAS1 · 9,000 · G | Altair 700 · 9,000 | |
|---|---|---|
| Heats down to | -15 °C | -15 °C |
| Max heat at -15 °C | – | 10,300 BTU/h |
| SEER2 | – | 30 |
| HSPF2 | – | 12.6 |
| Lowest indoor sound | 19 dB(A) | 19 dB(A) |
| Indoor weight | 10 kg | 10 kg |
| Max line set | 20 m | 20 m |
| Indicative LogisVert | $0 | $0 |
Same size and the same -15 °C floor, Cold Climate certified. Fujitsu now calls it ’Better-Tier’, as the LMAS1 was.
LMAS1 · 9,000 · H vs Altair 700 · 9,000
| LMAS1 · 9,000 · H | Altair 700 · 9,000 | |
|---|---|---|
| Heats down to | -15 °C | -15 °C |
| Max heat at -15 °C | 10,200 BTU/h | 10,300 BTU/h |
| SEER2 | 26.5 | 30 |
| HSPF2 | 12.6 | 12.6 |
| Lowest indoor sound | 19 dB(A) | 19 dB(A) |
| Indoor weight | 10 kg | 10 kg |
| Max line set | 20 m | 20 m |
| Indicative LogisVert | $0 | $0 |
Same size and the same -15 °C floor, Cold Climate certified. Fujitsu now calls it ’Better-Tier’, as the LMAS1 was.
LMAS1 · 12,000 · G vs Altair 700 · 12,000
| LMAS1 · 12,000 · G | Altair 700 · 12,000 | |
|---|---|---|
| Heats down to | -15 °C | -15 °C |
| Max heat at -15 °C | – | 10,600 BTU/h |
| SEER2 | – | 27.5 |
| HSPF2 | – | 11.2 |
| Lowest indoor sound | 19 dB(A) | 19 dB(A) |
| Indoor weight | 10 kg | 10 kg |
| Max line set | 20 m | 20 m |
| Indicative LogisVert | $0 | $1,044 |
Same size and the same -15 °C floor, Cold Climate certified. Fujitsu now calls it ’Better-Tier’, as the LMAS1 was.
LMAS1 · 12,000 · H vs Altair 700 · 12,000
| LMAS1 · 12,000 · H | Altair 700 · 12,000 | |
|---|---|---|
| Heats down to | -15 °C | -15 °C |
| Max heat at -15 °C | 10,700 BTU/h | 10,600 BTU/h |
| SEER2 | 23 | 27.5 |
| HSPF2 | 11.1 | 11.2 |
| Lowest indoor sound | 19 dB(A) | 19 dB(A) |
| Indoor weight | 10 kg | 10 kg |
| Max line set | 20 m | 20 m |
| Indicative LogisVert | $440 | $1,044 |
Same size and the same -15 °C floor, Cold Climate certified. Fujitsu now calls it ’Better-Tier’, as the LMAS1 was.
LMAS1 · 18,000 vs Altair 500 · 18,000
| LMAS1 · 18,000 | Altair 500 · 18,000 | |
|---|---|---|
| Heats down to | -15 °C | -15 °C |
| Max heat at -15 °C | 21,600 BTU/h | 18,500 BTU/h |
| SEER2 | 21.1 | 22 |
| HSPF2 | 11.5 | 10.5 |
| Lowest indoor sound | 30 dB(A) | 26 dB(A) |
| Indoor weight | 13 kg | 12.5 kg |
| Max line set | 50 m | 30 m |
| Indicative LogisVert | $1,632 | $1,356 |
Same size and the same -15 °C floor, Cold Climate certified.
LMAS1 · 18,000 vs Orion XLTH · 18,000
| LMAS1 · 18,000 | Orion XLTH · 18,000 | |
|---|---|---|
| Heats down to | -15 °C | -26 °C |
| Max heat at -15 °C | 21,600 BTU/h | 25,400 BTU/h |
| Max heat at -26.1 °C | – | 19,110 BTU/h |
| SEER2 | 21.1 | 25.5 |
| HSPF2 | 11.5 | 12.5 |
| Lowest indoor sound | 30 dB(A) | 30 dB(A) |
| Indoor weight | 13 kg | 16.5 kg |
| Max line set | 50 m | 50 m |
| Indicative LogisVert | $1,632 | $1,632 |
To keep the same rated output at -8 °C, and go down to -26 °C.
LMAS1 · 24,000 vs Altair 500 · 24,000
| LMAS1 · 24,000 | Altair 500 · 24,000 | |
|---|---|---|
| Heats down to | -15 °C | -15 °C |
| Max heat at -15 °C | 25,500 BTU/h | 20,000 BTU/h |
| SEER2 | 22.5 | 21.5 |
| HSPF2 | 11.4 | 10 |
| Lowest indoor sound | 33 dB(A) | 31 dB(A) |
| Indoor weight | 16.5 kg | 12.5 kg |
| Max line set | 50 m | 30 m |
| Indicative LogisVert | $1,884 | $1,776 |
Same size and the same -15 °C floor, Cold Climate certified.
LMAS1 · 24,000 vs Orion XLTH · 24,000
| LMAS1 · 24,000 | Orion XLTH · 24,000 | |
|---|---|---|
| Heats down to | -15 °C | -26 °C |
| Max heat at -15 °C | 25,500 BTU/h | 25,800 BTU/h |
| Max heat at -26.1 °C | – | 19,110 BTU/h |
| SEER2 | 22.5 | 24 |
| HSPF2 | 11.4 | 11.9 |
| Lowest indoor sound | 33 dB(A) | 30 dB(A) |
| Indoor weight | 16.5 kg | 16.5 kg |
| Max line set | 50 m | 50 m |
| Indicative LogisVert | $1,884 | $1,908 |
To keep the same rated output at -8 °C, and go down to -26 °C.
R-410A: what the rules really say.
In Canada, what is capped is the total amount of HFCs, not the servicing of your heat pump. US dates are shown for comparison, in grey.
Canada ratifies the Kigali Amendment, which targets an 85% cut in HFCs by 2036.
Canada’s HFC phase-down starts: the cap is 90% of the baseline.
Québec: GWP limits for some refrigeration equipment. Heat pumps are not covered.
Canada’s cap drops to 60% of the baseline, a 40% cut.
A GWP limit of 750 for chillers, in Canada and in Québec. Still nothing for residential heat pumps.
United States only: import deadline for residential R-410A products (EPA rule, per Fujitsu).
LogisVert requires ENERGY STAR certification, whatever the refrigerant.
United States only: installation deadline for new residential R-410A systems (per Fujitsu).
Canada’s cap drops to 30% of the baseline.
Canada’s cap drops to 20% of the baseline.
Canada’s cap reaches 15% of the baseline, the targeted 85% cut.
Key point: In Canada, what is capped is the total amount of HFCs, not the installation or servicing of an R-410A heat pump. The US dates are shown for comparison only.
Servicing an R-410A heat pump in Québec
In Québec, you can have your R-410A heat pump serviced and repaired for its whole useful life.
Québec’s halocarbon regulation limits the GWP of refrigeration equipment and chillers, not that of residential heat pumps.
Only a person holding the attestation required by the regulation may install, service, repair, charge or drain the unit.
Refrigerant must never be released into the air. It is recovered before any repair or removal.
A leaking unit isn’t simply topped up. A leak test comes before any refill.
The regulation’s annual leak test targets air-conditioning equipment of 20 kW and more, a size no wall heat pump in these families reaches.
R-32 can’t go into an R-410A system. Fujitsu says it is not a drop-in replacement.
Indoor and outdoor units pair within the same generation. Plan a full-system replacement when the time comes.
Canada doesn’t ban R-410A. It caps the amount of HFCs: 60% of the baseline until 2028, then 30% from 2029.
Fujitsu warranty: 5 years parts and 7 years compressor, up to 12 years with online registration within 60 days and a Fujitsu Elite contractor. Labour isn’t covered by Fujitsu.
Register the unit online within 60 days of installation. That’s the condition for the extended warranty.
Every size, line by line.
| LMAS1 9,000 BTU/h (Generation G) | LMAS1 9,000 BTU/h (Generation H) | LMAS1 12,000 BTU/h (Generation G) | LMAS1 12,000 BTU/h (Generation H) | LMAS1 18,000 BTU/h | LMAS1 24,000 BTU/h | |
|---|---|---|---|---|---|---|
| Indoor unit | ASUG09LMAS | ASUH09LMAS | ASUG12LMAS | ASUH12LMAS | ASUH18LMAS | ASUH24LMAS |
| Outdoor unit | AOUG09LMAS1 | AOUH09LMAS1 | AOUG12LMAS1 | AOUH12LMAS1 | AOUH18LMAS1 | AOUH24LMAS1 |
| AHRI number | 204752937 | 207615688 | 204752938 | 207615689 | 206913027 | 206913028 |
| Heats down to | -15 °C | -15 °C | -15 °C | -15 °C | -15 °C | -15 °C |
| Rated heating | 12,000 BTU/h | 12,000 BTU/h | 16,000 BTU/h | – | 21,600 BTU/h | 25,200 BTU/h |
| Rated cooling | 9,000 BTU/h | 9,000 BTU/h | 12,000 BTU/h | 12,000 BTU/h | 18,000 BTU/h | 22,000 BTU/h |
| SEER2 | – | 26.5 | – | 23 | 21.1 | 22.5 |
| EER2 | – | 14.3 | – | 12.5 | 13 | 12.5 |
| HSPF2 | – | 12.6 | – | 11.1 | 11.5 | 11.4 |
| Indoor sound (min / max) | 19 / 43 dB(A) | 19 / 43 dB(A) | 19 / 43 dB(A) | 19 / 43 dB(A) | 30 / 46 dB(A) | 33 / 46 dB(A) |
| Outdoor sound | 48 dB(A) | 48 dB(A) | 51 dB(A) | 51 dB(A) | 50 dB(A) | 54 dB(A) |
| Indoor, w×h×d | 834×270×222 mm | 834×270×222 mm | 834×270×222 mm | 834×270×222 mm | 980×280×240 mm | 1,150×340×280 mm |
| Outdoor, w×h×d | 799×542×290 mm | 799×542×290 mm | 799×542×290 mm | 799×542×290 mm | 940×788×320 mm | 940×788×320 mm |
| Weight in / out | 10 / 31 kg | 10 / 31 kg | 10 / 32 kg | 10 / 32 kg | 13 / 53 kg | 16.5 / 53 kg |
| Max line set / height | 20 / 15 m | 20 / 15 m | 20 / 15 m | 20 / 15 m | 50 / 30 m | 50 / 30 m |
| Breaker | – | 15 A | – | – | – | – |
| Refrigerant charge | – | 0.9 kg | – | 1 kg | – | 2.1 kg |
| ENERGY STAR | Not ENERGY STAR listed | ENERGY STAR cold climate | Not ENERGY STAR listed | ENERGY STAR | ENERGY STAR cold climate | ENERGY STAR cold climate |
| Indicative LogisVert | $0 | $0 | $0 | $440 | $1,632 | $1,884 |
Data from Fujitsu submittal sheets and manuals, the ENERGY STAR list and the NEEP list, read October 8, 2026. Dimensions in millimetres: width × height × depth.
What the LMAS1 sheets tell.
Two generations share the LMAS1 name. The G or H in the model number tells them apart.
Source: Fujitsu19 dB(A) at quiet speed, below a whisper heard a metre away (20 dBA).
Source: Fujitsu, Government of QuébecThe 18,000 delivers 21,600 BTU/h at -15 °C, more than its nominal size.
Source: ENERGY STARThe 18,000 and 24,000 accept up to 50 m of line set and 30 m of height difference.
Source: FujitsuThe Generation H 9,000 and 12,000 speak BACnet and Modbus.
Source: FujitsuLaunched in 2020, the LMAS1 took over from the RLFW1.
Source: FujitsuUp to 12 years on parts and compressor.
The longest tier needs online registration within 60 days and a Fujitsu Elite contractor. At AirGreen, both are done for you.
Fujitsu limited warranty statement for R-410A (version 10/2024): labour is not covered by Fujitsu, and the 10-year tier covers systems bought after January 1, 2022.
We register your unit with Fujitsu, free, on time.
The condition for the 12-year tier. AirGreen is Elite Plus.
The warranty requires a licensed contractor. RBQ 5645-9605-01.
Fujitsu’s text excludes systems bought from an online retailer.
Fujitsu’s efficiency, AirGreen’s diagnosis.
G or H? Before servicing, replacing a part or talking LogisVert, we read the label. AirGreen tells them apart for you.
What FUJITSU AIRSTAGE brings
- Two generationsSame name, different sheets.
- From 19 dB(A)At 9,000 and 12,000, according to Fujitsu.
- Up to 50 mOf line set on the 18,000 and 24,000.
- Up to 12 yearsParts and compressor, on Fujitsu’s conditions.
What AirGreen brings
- Elite Plus dealerThe highest level of the AIRSTAGE Elite program.
- Free home estimateWe measure and check the insulation and the location.
- Warranty registered for youWith Fujitsu, within 60 days.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: the right generation identified, and the right R-32 successor when the time comes.
Elite Plus: the highest level of the AIRSTAGE Elite program.
Fujitsu’s Japanese engineering, installed by an Elite Plus team across Montreal, Laval, Longueuil, the North Shore, the South Shore and Montérégie.
The highest level of the AIRSTAGE Elite program.
Our technicians take the manufacturer’s training on AIRSTAGE systems.
Vacuum, refrigerant settings, electrical hookup, set up for winter.
Manufacturer parts and Fujitsu technical support, wherever we install.
Free. We measure and check the insulation and the location.
The model, the size and the indicative LogisVert amount, in writing.
Vacuum, refrigerant, electrical, winter settings.
We register the unit with Fujitsu and help you with LogisVert.
What people ask us about the LMAS1.
No question matches. Call us at 514 316-2973.
They are two generations: G, from 2021, retired by Fujitsu, and the newer H. Only the H is ENERGY STAR certified.
-15 °C according to Fujitsu, for every size.
$440 for the Generation H 12,000, $1,632 for the 18,000 and $1,884 for the 24,000; $0 for the 9,000s and the Generation G 12,000.
No. It’s an optional adapter on every LMAS1.
The 9,000 and 12,000 indoor units are rated 19 dB(A) in cooling at quiet speed, in the lab.
20 m maximum for the 9,000 and 12,000; 50 m for the 18,000 and 24,000.
The Generation H 9,000 and 12,000 are BACnet and Modbus compatible, according to Fujitsu.
No. The whole series is listed among retired models.
The R-32 Altair 700 for the 9,000 and 12,000; for the 18,000 and 24,000, the Altair 500 (-15 °C) or the Orion XLTH (-26 °C).
An apple-catechin filter and an ion deodorizing filter, plus the washable panel filter.
Yes. Fujitsu lists cooling operation down to -10 °C outdoors.
Related collections.
The XLTH version: the same indoor unit, down to -26 °C.
View the collectionR-32Altair 700Its R-32 successor in 9,000 and 12,000.
View the collectionR-32Altair 500Its R-32 successor in 18,000 and 24,000.
View the collectionR-410ARLXThe RLXFW1, which Fujitsu replaced with the 18,000 and 24,000 LMAS1.
View the collectionA LMAS1, or its successor, installed by an Elite Plus team.
We come and see the room, show you the LMAS1 and its R-32 successor side by side, with their LogisVert amounts, and give you a clear quote.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump: hang up.
Sources checked on October 8, 2026
47 sources · show
- Fujitsu AIRSTAGE, airstagehvac.com/v1/products?productIds=<model>
- Fujitsu, product or archive page IDX
- Fujitsu AIRSTAGE, airstagehvac.com/split/wall
- Fujitsu AIRSTAGE, document pdf-fcus-halcyon-warranty-202410
- Fujitsu AIRSTAGE, airstagehvac.com/halcyon/warranty
- Fujitsu AIRSTAGE, document pdf-fcus-h-series-warranty-r32-202606
- Fujitsu AIRSTAGE, airstagehvac.com/benefits/next-gen-r32
- Fujitsu AIRSTAGE, document pdf-fcus-media-library-pr-lz-lm-nr-01
- Fujitsu, submittal sheet 2021.01.21
- Fujitsu, technical document 09LMAS1_Submittal_09LMAS1
- Fujitsu, technical document 12LMAS1_Submittal_12LMAS1
- Fujitsu, technical document 18LMAS1_Submittal_18LMAS1
- Fujitsu, technical document 24LMAS1_Submittal_24LMAS1
- Fujitsu, design manual AS143EF_03
- Fujitsu, product or archive page SER-RLFW1
- Fujitsu AIRSTAGE, airstagehvac.com/r32/kmas1
- Fujitsu, brochure FG8150C
- Fujitsu, brochure FG8150D
- Fujitsu, technical document 09KMAS1_Submittal_09KMAS1_R32
- Fujitsu, technical document 12KMAS1_Submittal_12KMAS1_R32
- Fujitsu AIRSTAGE, airstagehvac.com/split/featureicon
- Fujitsu AIRSTAGE, airstagehvac.com/r32/kpas1
- Fujitsu, brochure FG8151C
- Fujitsu, brochure FG8151D
- Fujitsu, submittal sheet 09KPAS1
- Fujitsu, submittal sheet 12KPAS1
- Fujitsu, submittal sheet 18KPAS1
- Fujitsu, submittal sheet 24KPAS1
- Fujitsu, submittal sheet 30KPAS1
- Fujitsu, submittal sheet 36KPAS1
- Fujitsu, design manual AS237ES_02
- ENERGY STAR, certified air-source heat pump list (dataset w7cv-9xjt)
- NEEP, cold-climate heat pump list
- Hydro-Québec, LogisVert residential participation guide, version 1.10
- Hydro-Québec, LogisVert partner notice (ENERGY STAR required)
- Government of Québec, mesure du bruit
- Government of Québec, Q 2,%20r.%2029
- Government of Québec, faq en
- Government of Canada, closed canada greener homes grant quebec
- Government of Canada, FullText
- Government of Canada, depleting substances halocarbon alternatives regulations
- Government of Canada, ozone regulations amendments questions
- International Astronomical Union, star and constellation names
- NASA, summer triangle corner altair
- Trade press, hvacrbusiness.com
- airgreen.ca product sheets, read October 8, 2026
- AirGreen, “Nos réalisations” projects blog
Amounts shown are estimates; only Hydro-Québec confirms the grant. Manufacturer data is quoted “according to Fujitsu”.
The LMAS1 units, right below.