Added to comparison
-
Added to comparison
-
Added to comparison
LZAS1: Fujitsu’s “Highest SEER” wall unit, down to -21 °C.
Fujitsu ranked it at the top for efficiency: SEER2 of 33.1 for the 9,000. Rated down to -21 °C, with no automatic cut-out, it is the LZAH1’s twin: same indoor unit, different outdoor unit. Here are its real numbers, and its R-32 successor.
LZAS1 · R-410A
Launched in 2020, it replaced the RLS3Y. Its series name at Fujitsu: “Highest SEER”.
Efficiency first.
Facts from Fujitsu sheets, the ENERGY STAR list and the NEEP list. Sources are at the bottom of the page.
At -21 °C, the 12,000 still delivers up to 15,000 BTU/h, more than its nominal size.
Fujitsu filed it as ’Highest SEER’: SEER2 33.1 for the 9,000.
Rated to -21 °C, with no automatic cut-out below it, according to Fujitsu.
Same indoor unit as the LZAH1; only the outdoor unit changes.
The 15,000 keeps 87% of its capacity between 8 °C and -15 °C, according to the data reported to NEEP.
Eight R-410A series, from the coldest floor to the mildest.
Before R-32, Fujitsu wall units ran on R-410A. Each card gives the series’ heating floor; the LZAS1 is highlighted.
9,000, 12,000 or 15,000 BTU/h.
Tap a size: photo, link to the product sheet, heat at -15 °C when Fujitsu publishes it, efficiency and LogisVert amount.
| Model | Heats down to | Max at -15 °C | SEER2 | HSPF2 | LogisVert | AHRI |
|---|---|---|---|---|---|---|
| LZAS1 9,000 BTU/h | -21 °C | 15,400 BTU/h | 33.1 | 13.4 | $0 | 206597208 |
| LZAS1 12,000 BTU/h | -21 °C | 16,600 BTU/h | 29.4 | 12.9 | $1,200 | 206597210 |
| LZAS1 15,000 BTU/h | -21 °C | 21,000 BTU/h | 25.3 | 12.8 | $1,344 | 206597212 |
The indoor unit, to scale
Front face drawn to scale, with the 1 m ruler. Dimensions: width × height × depth, according to Fujitsu.
Down to -21 °C, then the LZAH1 takes over.
The bars show the maximum published heat; the red tick, the ENERGY STAR value LogisVert uses; the dotted line, the nominal size. Fujitsu publishes fewer points for its older series: a dash means “not published”.
| Size | 8.3 °C | -8.3 °C | -15 °C | -21.1 °C |
|---|---|---|---|---|
| 9,000 BTU/h | 22,000 BTU/h | 16,000 BTU/h | 15,400 BTU/h | 14,000 BTU/h |
| 12,000 BTU/h | 22,100 BTU/h | 17,500 BTU/h | 16,600 BTU/h | 15,000 BTU/h |
| 15,000 BTU/h | 23,900 BTU/h | 21,500 BTU/h | 21,000 BTU/h | 18,600 BTU/h |
Operating ranges
Outdoor operating temperatures published by Fujitsu.
LZAS1 or LZAH1: where one stops, the other carries on.
Same indoor unit: only the outdoor unit changes the floor. Pick a size to compare.
LZAS1 · 9,000 vs LZAH1 · 9,000
| LZAS1 · 9,000 | LZAH1 · 9,000 | |
|---|---|---|
| Heats down to | -21 °C | -26 °C |
| Max heat at -15 °C | 15,400 BTU/h | 15,400 BTU/h |
| Max heat at -26.1 °C | – | 11,100 BTU/h |
| SEER2 | 33.1 | 33.1 |
| HSPF2 | 13.4 | 13.3 |
| Lowest indoor sound | 23 dB(A) | 23 dB(A) |
| Indoor weight | 13 kg | 13 kg |
| Max line set | 20 m | 20 m |
| Indicative LogisVert | $0 | $0 |
Same indoor unit, same efficiency: below -21 °C, the LZAH1 and its heated base pan keep going, down to -26 °C.
LZAS1 · 12,000 vs LZAH1 · 12,000
| LZAS1 · 12,000 | LZAH1 · 12,000 | |
|---|---|---|
| Heats down to | -21 °C | -26 °C |
| Max heat at -15 °C | 16,600 BTU/h | 16,600 BTU/h |
| Max heat at -26.1 °C | – | 11,800 BTU/h |
| SEER2 | 29.4 | 29.4 |
| HSPF2 | 12.9 | 12.7 |
| Lowest indoor sound | 23 dB(A) | 23 dB(A) |
| Indoor weight | 13 kg | 13 kg |
| Max line set | 20 m | 20 m |
| Indicative LogisVert | $1,200 | $1,200 |
Same indoor unit, same efficiency: below -21 °C, the LZAH1 and its heated base pan keep going, down to -26 °C.
LZAS1 · 15,000 vs LZAH1 · 15,000
| LZAS1 · 15,000 | LZAH1 · 15,000 | |
|---|---|---|
| Heats down to | -21 °C | -26 °C |
| Max heat at -15 °C | 21,000 BTU/h | 21,000 BTU/h |
| Max heat at -26.1 °C | – | 16,300 BTU/h |
| SEER2 | 25.3 | 25.3 |
| HSPF2 | 12.8 | 12.7 |
| Lowest indoor sound | 26 dB(A) | 26 dB(A) |
| Indoor weight | 13 kg | 13 kg |
| Max line set | 20 m | 20 m |
| Indicative LogisVert | $1,344 | $1,344 |
Same indoor unit, same efficiency: below -21 °C, the LZAH1 and its heated base pan keep going, down to -26 °C.
What Fujitsu put in it.
Fujitsu lists this series among its retired models. It stays in AirGreen’s catalogue: we confirm availability at quote time, and show you its R-32 successor alongside.
Optional Wi-Fi: a wireless adapter, sold separately, adds app control.
The earlier LZAS indoor unit had built-in Wi-Fi; the LZBS unit we install needs the adapter.
No automatic cut-out in cold weather, according to Fujitsu, though output isn’t rated below the listed range.
Minimum heat mode: the room stays at 10 °C while you’re away.
Powerful mode: 20 minutes at maximum airflow and compressor speed.
Economy mode: the set point adjusts to avoid over-heating or over-cooling.
Energy Saving Program (ESP): the set point adjusts when the room stays empty, according to Fujitsu.
Quiet schedule for the outdoor unit.
Weekly timer and 24-hour timer.
Apple-catechin filter and ion deodorizing filter, according to Fujitsu.
Two indoor units, two answers.
Depending on the indoor unit installed, Wi-Fi is built in or needs an adapter. Tap the prefix printed on your label.
| Indoor unit | Wi-Fi |
|---|---|
| ASUG..LZAS | Built-in Wi-Fi |
| ASUG..LZBS | Wi-Fi with an adapter |
Check the indoor unit’s label: the model prefix tells you whether Wi-Fi is already there. The two adapter names come from two Fujitsu documents; we confirm the right one at installation.
SEER2 drops as size goes up.
SEER2 measures cooling efficiency over a season. On the LZAS1, the smallest is the most efficient.
23 dB(A) on quiet speed.
Place each size on the scale of everyday sounds.
| Model | Indoor, quiet speed | Indoor, high speed | Outdoor unit |
|---|---|---|---|
| LZAS1 9,000 BTU/h | 23 dB(A) | 43 dB(A) | 47 dB(A) |
| LZAS1 12,000 BTU/h | 23 dB(A) | 43 dB(A) | 47 dB(A) |
| LZAS1 15,000 BTU/h | 26 dB(A) | 45 dB(A) | 50 dB(A) |
Levels published by Fujitsu, measured in a lab; at home, the room, the furniture and the distance change what you hear. Scale: Government of Québec reference points.
Up to 20 m of line set and 15 m of height difference.
Drag the sliders to place the outdoor unit: the tool applies Fujitsu’s limits and the refrigerant to add beyond the pre-charge.
| Model | Max length | Max height | Pre-charge | Minimum |
|---|---|---|---|---|
| LZAS1 9,000 BTU/h | 20 m | 15 m | 15 m | 5 m |
| LZAS1 12,000 BTU/h | 20 m | 15 m | 15 m | 5 m |
| LZAS1 15,000 BTU/h | 20 m | 15 m | 15 m | 5 m |
Up to $1,344 for the 15,000.
R-410A is not excluded by LogisVert: what counts is the ENERGY STAR list and the 12,000 BTU/h minimum size.
| Model | Indicative amount | Calculation |
|---|---|---|
| LZAS1 9,000 BTU/h | $0 | – |
| LZAS1 12,000 BTU/h | $1,200 | 10,000 BTU/h ÷ 1,000 × $120 = $1,200 |
| LZAS1 15,000 BTU/h | $1,344 | 11,200 BTU/h ÷ 1,000 × $120 = $1,344 |
Since November 26, 2025, only ENERGY STAR certified heat pumps qualify.
The outdoor unit must be at least 12,000 BTU/h nominal in cooling.
The grant never exceeds the purchase and installation cost, before taxes.
You apply no later than nine months after installation.
July 8, 2027
LogisVert residential participation guide, version 1.10 of September 15, 2026. Indicative amounts, calculated with the ENERGY STAR value at -8 °C (17 °F); only Hydro-Québec confirms the grant, with the AHRI number.
What replaces the LZAS1 today.
Pick a size: the LZAS1 on the left, the R-32 model that replaces it on the right, with the figures from Fujitsu, ENERGY STAR and LogisVert. The better value on each row is in green.
LZAS1 · 9,000 vs Orion XLTH · 9,000
| LZAS1 · 9,000 | Orion XLTH · 9,000 | |
|---|---|---|
| Heats down to | -21 °C | -26 °C |
| Max heat at -15 °C | 15,400 BTU/h | 15,400 BTU/h |
| Max heat at -26.1 °C | – | 11,400 BTU/h |
| SEER2 | 33.1 | 33.1 |
| HSPF2 | 13.4 | 13.3 |
| Lowest indoor sound | 23 dB(A) | 23 dB(A) |
| Indoor weight | 13 kg | 12.5 kg |
| Max line set | 20 m | 25 m |
| Indicative LogisVert | $0 | $0 |
No R-32 wall unit stops at -21 °C. The Orion XLTH, same size, goes down to -26 °C, so you lose no cold-weather coverage.
LZAS1 · 9,000 vs Altair 700 · 9,000
| LZAS1 · 9,000 | Altair 700 · 9,000 | |
|---|---|---|
| Heats down to | -21 °C | -15 °C |
| Max heat at -15 °C | 15,400 BTU/h | 10,300 BTU/h |
| SEER2 | 33.1 | 30 |
| HSPF2 | 13.4 | 12.6 |
| Lowest indoor sound | 23 dB(A) | 19 dB(A) |
| Indoor weight | 13 kg | 10 kg |
| Max line set | 20 m | 20 m |
| Indicative LogisVert | $0 | $0 |
If -15 °C is enough for your home: the same size, Cold Climate certified.
LZAS1 · 12,000 vs Orion XLTH · 12,000
| LZAS1 · 12,000 | Orion XLTH · 12,000 | |
|---|---|---|
| Heats down to | -21 °C | -26 °C |
| Max heat at -15 °C | 16,600 BTU/h | 16,600 BTU/h |
| Max heat at -26.1 °C | – | 12,200 BTU/h |
| SEER2 | 29.4 | 30.5 |
| HSPF2 | 12.9 | 12.7 |
| Lowest indoor sound | 23 dB(A) | 23 dB(A) |
| Indoor weight | 13 kg | 12.5 kg |
| Max line set | 20 m | 25 m |
| Indicative LogisVert | $1,200 | $1,200 |
No R-32 wall unit stops at -21 °C. The Orion XLTH, same size, goes down to -26 °C, so you lose no cold-weather coverage.
LZAS1 · 12,000 vs Altair 700 · 12,000
| LZAS1 · 12,000 | Altair 700 · 12,000 | |
|---|---|---|
| Heats down to | -21 °C | -15 °C |
| Max heat at -15 °C | 16,600 BTU/h | 10,600 BTU/h |
| SEER2 | 29.4 | 27.5 |
| HSPF2 | 12.9 | 11.2 |
| Lowest indoor sound | 23 dB(A) | 19 dB(A) |
| Indoor weight | 13 kg | 10 kg |
| Max line set | 20 m | 20 m |
| Indicative LogisVert | $1,200 | $1,044 |
If -15 °C is enough for your home: the same size, Cold Climate certified.
LZAS1 · 15,000 vs Orion XLTH · 15,000
| LZAS1 · 15,000 | Orion XLTH · 15,000 | |
|---|---|---|
| Heats down to | -21 °C | -26 °C |
| Max heat at -15 °C | 21,000 BTU/h | 21,000 BTU/h |
| Max heat at -26.1 °C | – | 16,400 BTU/h |
| SEER2 | 25.3 | 27.5 |
| HSPF2 | 12.8 | 12.7 |
| Lowest indoor sound | 26 dB(A) | 26 dB(A) |
| Indoor weight | 13 kg | 12.5 kg |
| Max line set | 20 m | 30 m |
| Indicative LogisVert | $1,344 | $1,368 |
No R-32 wall unit stops at -21 °C. The Orion XLTH, same size, goes down to -26 °C, so you lose no cold-weather coverage.
R-410A: what the rules really say.
In Canada, what is capped is the total amount of HFCs, not the servicing of your heat pump. US dates are shown for comparison, in grey.
Canada ratifies the Kigali Amendment, which targets an 85% cut in HFCs by 2036.
Canada’s HFC phase-down starts: the cap is 90% of the baseline.
Québec: GWP limits for some refrigeration equipment. Heat pumps are not covered.
Canada’s cap drops to 60% of the baseline, a 40% cut.
A GWP limit of 750 for chillers, in Canada and in Québec. Still nothing for residential heat pumps.
United States only: import deadline for residential R-410A products (EPA rule, per Fujitsu).
LogisVert requires ENERGY STAR certification, whatever the refrigerant.
United States only: installation deadline for new residential R-410A systems (per Fujitsu).
Canada’s cap drops to 30% of the baseline.
Canada’s cap drops to 20% of the baseline.
Canada’s cap reaches 15% of the baseline, the targeted 85% cut.
Key point: In Canada, what is capped is the total amount of HFCs, not the installation or servicing of an R-410A heat pump. The US dates are shown for comparison only.
Servicing an R-410A heat pump in Québec
In Québec, you can have your R-410A heat pump serviced and repaired for its whole useful life.
Québec’s halocarbon regulation limits the GWP of refrigeration equipment and chillers, not that of residential heat pumps.
Only a person holding the attestation required by the regulation may install, service, repair, charge or drain the unit.
Refrigerant must never be released into the air. It is recovered before any repair or removal.
A leaking unit isn’t simply topped up. A leak test comes before any refill.
The regulation’s annual leak test targets air-conditioning equipment of 20 kW and more, a size no wall heat pump in these families reaches.
R-32 can’t go into an R-410A system. Fujitsu says it is not a drop-in replacement.
Indoor and outdoor units pair within the same generation. Plan a full-system replacement when the time comes.
Canada doesn’t ban R-410A. It caps the amount of HFCs: 60% of the baseline until 2028, then 30% from 2029.
Fujitsu warranty: 5 years parts and 7 years compressor, up to 12 years with online registration within 60 days and a Fujitsu Elite contractor. Labour isn’t covered by Fujitsu.
Register the unit online within 60 days of installation. That’s the condition for the extended warranty.
Every size, line by line.
| LZAS1 9,000 BTU/h | LZAS1 12,000 BTU/h | LZAS1 15,000 BTU/h | |
|---|---|---|---|
| Indoor unit | ASUG09LZBS | ASUG12LZBS | ASUG15LZBS |
| Outdoor unit | AOUG09LZAS1 | AOUG12LZAS1 | AOUG15LZAS1 |
| AHRI number | 206597208 | 206597210 | 206597212 |
| Heats down to | -21 °C | -21 °C | -21 °C |
| Rated heating | 12,000 BTU/h | 16,000 BTU/h | 18,000 BTU/h |
| Rated cooling | 9,000 BTU/h | 12,000 BTU/h | 14,500 BTU/h |
| SEER2 | 33.1 | 29.4 | 25.3 |
| EER2 | 18 | 15.2 | 13.9 |
| HSPF2 | 13.4 | 12.9 | 12.8 |
| Indoor sound (min / max) | 23 / 43 dB(A) | 23 / 43 dB(A) | 26 / 45 dB(A) |
| Outdoor sound | 47 dB(A) | 47 dB(A) | 50 dB(A) |
| Indoor, w×h×d | 980×280×240 mm | 980×280×240 mm | 980×280×240 mm |
| Outdoor, w×h×d | 799×632×290 mm | 799×632×290 mm | 799×632×290 mm |
| Weight in / out | 13 / 38 kg | 13 / 38 kg | 13 / – kg |
| Max line set / height | 20 / 15 m | 20 / 15 m | 20 / 15 m |
| Breaker | – | 15 A | – |
| Refrigerant charge | 1.3 kg | 1.3 kg | 1.4 kg |
| ENERGY STAR | ENERGY STAR cold climate | ENERGY STAR cold climate | ENERGY STAR cold climate |
| Indicative LogisVert | $0 | $1,200 | $1,344 |
Data from Fujitsu submittal sheets and manuals, the ENERGY STAR list and the NEEP list, read October 8, 2026. Dimensions in millimetres: width × height × depth.
What the LZAS1 sheets tell.
The 12,000 still delivers up to 15,000 BTU/h at -21 °C.
Source: NEEPFujitsu filed it as ’Highest SEER’. The 9,000 is rated SEER2 33.1.
Source: Fujitsu, ENERGY STARLaunched in 2020, it replaced the RLS3Y.
Source: FujitsuSame indoor units as the LZAH1. Only the outdoor unit changes.
Source: ENERGY STARNo automatic cut-out in deep cold, even below -21 °C, according to Fujitsu.
Source: FujitsuIts ion deodorizing filter is washable and lasts about 3 years, according to Fujitsu.
Source: FujitsuUp to 12 years on parts and compressor.
The longest tier needs online registration within 60 days and a Fujitsu Elite contractor. At AirGreen, both are done for you.
Fujitsu limited warranty statement for R-410A (version 10/2024): labour is not covered by Fujitsu, and the 10-year tier covers systems bought after January 1, 2022.
We register your unit with Fujitsu, free, on time.
The condition for the 12-year tier. AirGreen is Elite Plus.
The warranty requires a licensed contractor. RBQ 5645-9605-01.
Fujitsu’s text excludes systems bought from an online retailer.
Fujitsu’s efficiency, AirGreen’s servicing.
An LZAS1 can be serviced and repaired in Québec for its whole useful life. AirGreen knows it, and knows its R-32 successor.
What FUJITSU AIRSTAGE brings
- SEER2 33.1For the 9,000, per ENERGY STAR.
- Down to -21 °CNo automatic cut-out, according to Fujitsu.
- Cold climateAll three sizes, per ENERGY STAR.
- Up to 12 yearsParts and compressor, on Fujitsu’s conditions.
What AirGreen brings
- Elite Plus dealerThe highest level of the AIRSTAGE Elite program.
- Free home estimateWe measure and check the insulation and the location.
- Warranty registered for youWith Fujitsu, within 60 days.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: the right choice between an LZAS1, an LZAH1 and an Orion XLTH, with the numbers to back it.
Elite Plus: the highest level of the AIRSTAGE Elite program.
Fujitsu’s Japanese engineering, installed by an Elite Plus team across Montreal, Laval, Longueuil, the North Shore, the South Shore and Montérégie.
The highest level of the AIRSTAGE Elite program.
Our technicians take the manufacturer’s training on AIRSTAGE systems.
Vacuum, refrigerant settings, electrical hookup, set up for winter.
Manufacturer parts and Fujitsu technical support, wherever we install.
Free. We measure and check the insulation and the location.
The model, the size and the indicative LogisVert amount, in writing.
Vacuum, refrigerant, electrical, winter settings.
We register the unit with Fujitsu and help you with LogisVert.
What people ask us about the LZAS1.
No question matches. Call us at 514 316-2973.
Fujitsu rates it to -21 °C. It has no automatic cut-out below that, but its output there isn’t rated.
Same indoor unit and same efficiency. The LZAH1 goes to -26 °C and has a base heater; the LZAS1 stops at -21 °C.
On the LZBS indoor unit we install, Wi-Fi needs the optional wireless adapter.
Yes, in all three sizes.
$0 for the 9,000, $1,200 for the 12,000 and $1,344 for the 15,000.
No. Fujitsu lists it among its retired models.
No R-32 wall unit has a -21 °C floor. The Orion XLTH (-26 °C) covers the same sizes; the Altair 700 (-15 °C) comes in 9,000 and 12,000.
20 m maximum, with 15 m of height difference; it’s pre-charged for 15 m.
An apple-catechin filter and an ion deodorizing filter, according to Fujitsu.
Yes. Minimum heat mode holds the room at 10 °C.
No. Servicing and repair remain allowed in Québec, by a qualified refrigeration technician.
Related collections.
A LZAS1, or its successor, installed by an Elite Plus team.
We come and see the room, show you the LZAS1 and its R-32 successor side by side, with their LogisVert amounts, and give you a clear quote.
Hydro-Québec does not solicit anyone by phone or door to door for LogisVert. A call “from Hydro-Québec” selling a heat pump: hang up.
Sources checked on October 8, 2026
52 sources · show
- Fujitsu AIRSTAGE, airstagehvac.com/v1/products?productIds=<model>
- Fujitsu, product or archive page IDX
- Fujitsu AIRSTAGE, airstagehvac.com/split/wall
- Fujitsu AIRSTAGE, document pdf-fcus-halcyon-warranty-202410
- Fujitsu AIRSTAGE, airstagehvac.com/halcyon/warranty
- Fujitsu AIRSTAGE, document pdf-fcus-h-series-warranty-r32-202606
- Fujitsu AIRSTAGE, airstagehvac.com/benefits/next-gen-r32
- Fujitsu AIRSTAGE, document pdf-fcus-media-library-pr-lz-lm-nr-01
- Fujitsu, technical document 09LZBS1_Submittal_09LZBS1
- Fujitsu, technical document 12LZBS1_Submittal_12LZBS1
- Fujitsu, technical document 15LZBS1_Submittal_15LZBS1
- Fujitsu, product or archive page SER-LZBS1
- Fujitsu, technical document 09LZBH1_Submittal_09LZBH1
- Fujitsu, technical document 12LZBH1_Submittal_12LZBH1
- Fujitsu, technical document 15LZBH1_Submittal_15LZBH1
- Fujitsu, technical document 12LZAH1_Submittal_12LZAH1
- Fujitsu, design manual AS142EF_02
- Fujitsu, product or archive page SER-RLS3H
- Fujitsu AIRSTAGE, airstagehvac.com/r32/kzah1
- Fujitsu, brochure FG8153C
- Fujitsu, brochure FG8153D
- Fujitsu, submittal sheet 09KZAH1
- Fujitsu, submittal sheet 12KZAH1
- Fujitsu, submittal sheet 15KZAH1
- Fujitsu, submittal sheet 18KZAH1
- Fujitsu, submittal sheet 24KZAH1
- Fujitsu, technical document &DR_AS233ES_01--ASUH09-15KZAS
- Fujitsu AIRSTAGE, airstagehvac.com/split/featureicon
- Fujitsu AIRSTAGE, airstagehvac.com/technology/xlth-low-temp-heating
- Fujitsu AIRSTAGE, airstagehvac.com/r32/kmas1
- Fujitsu, brochure FG8150C
- Fujitsu, brochure FG8150D
- Fujitsu, technical document 09KMAS1_Submittal_09KMAS1_R32
- Fujitsu, technical document 12KMAS1_Submittal_12KMAS1_R32
- ENERGY STAR, certified air-source heat pump list (dataset w7cv-9xjt)
- NEEP, cold-climate heat pump list
- Hydro-Québec, LogisVert residential participation guide, version 1.10
- Hydro-Québec, LogisVert partner notice (ENERGY STAR required)
- Government of Québec, mesure du bruit
- Government of Québec, Q 2,%20r.%2029
- Government of Québec, faq en
- Government of Canada, closed canada greener homes grant quebec
- Government of Canada, FullText
- Government of Canada, depleting substances halocarbon alternatives regulations
- Government of Canada, ozone regulations amendments questions
- International Astronomical Union, star and constellation names
- NASA, apod 2012 january 19 the hunters stars
- NASA, messier 42
- NASA, summer triangle corner altair
- Trade press, hvacrbusiness.com
- airgreen.ca product sheets, read October 8, 2026
- AirGreen, “Nos réalisations” projects blog
Amounts shown are estimates; only Hydro-Québec confirms the grant. Manufacturer data is quoted “according to Fujitsu”.
The LZAS1 units, right below.
Each product sheet gives the AHRI number and the indicative LogisVert amount. For R-32, see the Orion XLTH and the Altair 700.