STERLING HSB03611 Hot-Water Unit Heater | Montreal, Laval, Longueuil, South Shore & North Shore

In stock

The Sterling HSB03611 is a 26,100 BTU/h horizontal hot-water unit heater, a rating measured with 200°F water, to be chosen according to the actual temperature of your electric boiler or air-to-water heat pump.

Model numberHSB03611

26,100 BTU/hwith 200°F water (60°F air)
550 CFMairflow (480 at reduced speed)
25 Wenclosed 115 V motor
115 V · single phaseAir-to-water heat pump or electric boilerOutput depends on water temperature
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberHSB03611
ManufacturerSterling
Output (200°F water)26,100 BTU/h
Airflow550 CFM
Water flow2.7 GPM
Motor25 W, 115 V
MountingHung, horizontal

The right unit heater is chosen with your water temperature

Water temperature decides the output

The Sterling HSB03611 is a horizontal hot-water unit heater, mid-sized in the HS series. The manufacturer publishes 26,100 BTU/h under specific conditions: 200°F entering water, 60°F entering air and a 20°F drop between the water inlet and outlet. These conditions matter, because the heat a coil releases depends on the difference between the water temperature and the air temperature.

An electric boiler set high comes close to the rating. An air-to-water heat pump, on the other hand, generally works with cooler water. Sterling publishes the factors to apply: 0.857 at 180°F, 0.715 at 160°F, 0.571 at 140°F, 0.429 at 120°F and 0.286 at 100°F. We apply the one that matches your installation before recommending this model, or a neighbouring size such as the HSB02411 or the HSB04811.

Which spaces it suits

A craftsperson’s workshop on the ground floor of a plex, the showroom of a small business, the maintenance garage of a rental building: the HSB03611 targets spaces that need a solid heat supply, delivered from the ceiling. It blows 550 CFM, or 480 CFM at reduced speed, where Sterling publishes 23,500 BTU/h. The air outlet comes with horizontal louvers as standard.

On the loop side, it needs 2.7 GPM with a 20°F drop, for a pressure drop of 0.09 ft H2O. Its 25 W motor runs on 115 V, single phase, 60 Hz; it is single speed, totally enclosed with thermal overload protection. The coil is rated up to 150 PSI (1,034 kPa) or 320°F (160°C) on hot water, and also accepts a propylene glycol solution, for which Sterling publishes correction factors.

What AirGreen does

We start by reading the supply temperature of your electric boiler or air-to-water heat pump, then calculating the space’s heat loss. If the HSB03611 fits, our technicians hang it by rods from the connections provided, properly level. They connect it to the loop with isolation valves and air purging, make the 115 V electrical connection and install the control. Start-up includes checking the water flow and the temperature drop between inlet and outlet.

AirGreen is a family business established in Montreal for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work. We work in Montreal, Laval, Longueuil, the North Shore and the South Shore.

Get a calculation made for your building

The on-site estimate is free. You then receive a written quote stating the water temperature used and the resulting corrected output, with financing available.

01 · What it is for

A solid heat supply, delivered from the ceiling

The HSB03611 blows 550 CFM of air warmed by the water from your system. It suits commercial or work spaces where a baseboard is not enough and the floor has to stay clear.

  • Craftsperson’s workshop on the ground floor of a plex
  • Showroom or back shop of a small business
  • Maintenance garage of a rental building
  • Building heated by an air-to-water heat pump, sized at the actual water temperature
26,100 BTU/h at 200°FManufacturer’s rating with 200°F entering water, 60°F entering air and a 20°F drop; 23,500 BTU/h at reduced speed.
Enclosed 25 W motorSingle-speed 115 V motor, totally enclosed, with thermal overload protection.
Coil rated 150 PSIRated up to 150 PSI (1,034 kPa) or 320°F (160°C) on hot water, factory tested at 200 psig under water.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerSterling
TypeHorizontal hot-water unit heater, propeller fan
Catalogue designationHS-36
CoilStandard, header type (B)
Hot-water output26,100 BTU/h (200°F entering water, 60°F entering air, 20°F drop)
Output at reduced speed23,500 BTU/h (same conditions)
Airflow550 CFM (480 CFM at reduced speed)
Outlet air velocity550 FPM
Water flow2.7 GPM (20°F drop)
Water pressure drop0.09 ft H2O
Correction factors (60°F entering air)180°F water: 0.857 · 160°F: 0.715 · 140°F: 0.571 · 120°F: 0.429 · 100°F: 0.286
Motor25 W, single speed, totally enclosed with thermal overload protection
Power supply115 V, single phase, 60 Hz
Coil rating (hot water)Up to 150 PSI (1,034 kPa) or 320°F (160°C)
Factory test200 psig (1,379 kPa), under water
Air outletHorizontal louvers, standard
MountingHorizontal, hung by rods from the connections provided on the unit, level
Heat-transfer fluidHot water or propylene glycol solution (correction factors published by Sterling)
ListingETL
StandardsCSA C22.2, UL 1995, UL 60335-2-40
Model numberHSB03611
03 · Before installing

What to know before installing

  • With an air-to-water heat pump, check the planned water temperature: Sterling applies a factor of 0.571 at 140°F and 0.286 at 100°F to the 200°F rating.
  • Water flow to plan for: 2.7 GPM with a 20°F drop. The circulator must supply it in addition to the loop’s other circuits.
  • 115 V, single-phase, 60 Hz power supply at the location.
  • Pipe connection size and dimensions are not in the verified data: we confirm them with Sterling before ordering.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Hot-water unit heaters
See all
Same brand
STERLING
See all
06 · Questions

Frequently asked questions

I am told the water will be 120°F: what output should I expect?

Sterling applies a factor of 0.429 at 120°F to the 26,100 BTU/h rating measured at 200°F. We do that calculation with you and compare it with the space’s heat loss.

How do I choose between the HSB02411, HSB03611 and HSB04811?

They are neighbouring sizes in the same series. The choice is made on the output corrected to your water temperature, compared with the heat loss, not on the model number.

How much water has to circulate?

2.7 GPM with a 20°F drop. The coil’s pressure drop is then 0.09 ft H2O.

Can the coil handle my loop’s pressure?

Sterling rates it up to 150 PSI (1,034 kPa) or 320°F (160°C) on hot water, and factory tests it at 200 psig (1,379 kPa) under water.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

An HSB03611 chosen for your water, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.