DETTSON Suprême Avantage SUP18-A120D12 Electric Furnace | 18 kW - 240V

In stock

The Dettson Suprême Avantage SUP18-A120D12: an 18 kW electric furnace with a 4-speed PSC motor, supplied at 120–240/208 V on three wires.

Model numberSUP18-A120D12

18 kWat 240 V (13.5 kW at 208 V)
60 to 80 °Ftemperature rise at 240 V
4 speeds1/3 HP PSC motor
120–240/208 V · 3 wiresMulti-positionParts covered 5 years
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP18-A120D12
ManufacturerDettson
SeriesSuprême Avantage (PSC)
Output18 kW at 240 V
Power supply120–240/208 V, 1 ph, 60 Hz, 3 wires
Max. breaker100 A at 240 V
Max. cooling3 tons

18 kW of electric heat, ready for a three-wire supply

What sets the SUP18-A120D12 apart

In Dettson’s Suprême Avantage series, the SUP18-A120D12 is the 18 kW version designed for a 120–240/208 V single-phase three-wire supply. It delivers 18 kW at 240 V and 13.5 kW at 208 V, with a first stage of 9 kW at 240 V. Its 1/3 HP direct-drive PSC motor has 4 speeds; for heating, the speed is factory-set for 775 CFM at 0.5 in w.c.

You feel the result at the registers: Dettson publishes a temperature rise of 60 to 80 °F at 240 V. The elements switch on in sequence, quietly, and each one can be replaced individually.

The homes that need it

An 18 kW furnace makes sense when the heat-loss calculation calls for it: a larger single-family house, a multi-storey cottage or a plex heated by a single duct system. We do that calculation on site, room by room, before recommending this size rather than the 15 or 20 kW model from the same series. We come to you in Laval, Montreal, on the South Shore and on the North Shore.

On the electrical side, Dettson calls for a 100 A maximum breaker at 240 V (90 A at 208 V) and lists a 100.0 A ampacity. Your electrical service must be able to take this circuit: it is one of the first things we check.

Air conditioning, heat pump and location

The furnace accepts an air-conditioner or heat-pump coil on the supply or return side, up to 3 tons, with a maximum airflow of 1,150 CFM at 0.5 in w.c. With a heat pump, the elements become the backup heat, without ever running at the same time as the heat pump: Dettson does not allow it, to avoid overheating, and the K03081 interface manages the switchover.

Being multi-position, the Suprême installs upflow, downflow with the DFB-SUP base depending on the floor, horizontal or suspended. It is 36 1/2 in high and 22 in deep, and it is approved for zero clearance and for copper or aluminum wiring.

A complete installation by AirGreen

A family business established in Montreal for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work. In practice, we take care of:

  • the free on-site estimate and the written quote;
  • checking the three-wire supply and the panel;
  • setting the unit, wiring it and connecting it to the ducts;
  • choosing the motor speed and commissioning.

Dettson covers parts for 5 years in residential use; labour is not covered by the manufacturer. We also serve Longueuil and the surrounding area.

Get your quote

Contact us for a free estimate and a written quote tailored to your home. Financing solutions are available for your new furnace.

01 · What it is for

18 kW of electric heat for a duct system

The SUP18-A120D12 heats air with electric elements that switch on in sequence and distributes it with a 4-speed direct-drive PSC motor. It is wired on three wires and accepts an air-conditioning coil of up to 3 tons.

  • Ducted houses and plexes that need 18 kW according to the load calculation
  • Replacing an old furnace on a three-wire single-phase supply
  • Projects that add central air conditioning or a heat pump of up to 3 tons
  • Basement, horizontal or suspended installation
4-speed motorThe 1/3 HP PSC motor has 4 speeds; heating airflow is factory-set at 775 CFM at 0.5 in w.c.
Warm air at the registersDettson publishes a 60 to 80 °F temperature rise at 240 V.
Easier serviceIndividually replaceable elements and front-mounted breakers.
Compatible with
K03081DFB-SUP
Per the manufacturer. Send us the model number of your equipment and we confirm compatibility before ordering.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Avantage, PSC motor
TypeElectric furnace with elements, multi-position
Output18 kW at 240 V · 13.5 kW at 208 V
First-stage output9 kW at 240 V · 6.8 kW at 208 V
Heating output at 208 V46,130 BTU/h
Power supply120–240/208 V, 1 ph, 60 Hz, 3 wires
Total current82.6 / 71.5 A (240 / 208 V)
Ampacity100.0 / 87.0 A (240 / 208 V)
Max. breaker100 / 90 A (240 / 208 V)
MotorDirect-drive PSC, 1/3 HP, 4 speeds
Blower wheel12 x 8
Heating airflow775 CFM at 0.5 in w.c. (factory speed)
Max. airflow1,150 CFM at 0.5 in w.c.
Temperature rise60 to 80 °F (240 V)
Max. cooling3 tons (coil on supply or return)
PositionsUpflow (factory), downflow (DFB-SUP base), horizontal left or right, suspended
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Approved forZero clearance, mobile homes, copper or aluminum wiring
Manufacturer warrantyParts: 5 years (residential), 1 year (commercial); labour not covered
Model numberSUP18-A120D12
03 · Before installing

What to know before installing

  • Sold alone, an electric furnace is not a heat pump: it does not qualify for the LogisVert grant.
  • 120–240/208 V single-phase 3-wire supply: we check that your electrical service matches it.
  • Dedicated circuit: 100 A maximum breaker at 240 V (90 A at 208 V) and 100.0 A ampacity at 240 V according to Dettson.
  • With a heat pump, the elements and the heat pump must never heat at the same time (overheating risk according to Dettson): a thermostat or the K03081 interface must prevent it.
  • The air-conditioning or heat-pump coil is not included; it goes on the supply or return side.
  • In downflow, the DFB-SUP base may be required depending on the type of floor.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

What power supply does this model need?

A 120–240/208 V single-phase 3-wire supply, 60 Hz. The series also offers a 240 V version, the SUP18-A240D12: we tell you which one suits your electrical service.

What breaker is needed?

Dettson specifies a 100 A maximum breaker at 240 V (90 A at 208 V) and a 100.0 A ampacity at 240 V. We check your panel’s capacity during the free estimate.

Can I add central air conditioning?

Yes, up to 3 tons, with a coil on the supply or return side. The published maximum airflow is 1,150 CFM at 0.5 in w.c.

Does it work with a heat pump?

Yes, as backup heat, but never at the same time as the heat pump: Dettson does not allow it, to avoid overheating. The thermostat or the K03081 interface manages the switchover.

What is Dettson’s warranty?

Parts for 5 years in residential use and 1 year in commercial use. Labour is not covered by the manufacturer warranty.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

An 18 kW Suprême Avantage, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.