DETTSON Suprême Avantage SUP27-A120D20 Electric Furnace | 27 kW - 240V

In stock

The 3-wire 27 kW Dettson Suprême Avantage: a multi-position electric furnace with a 4-speed PSC motor, supplied at 120–240/208 V through two circuits.

Model numberSUP27-A120D20

27 kWat 240 V (20.3 kW at 208 V)
4 speedsdirect-drive PSC motor, 1 HP
50-70 °Ftemperature rise at 240 V
120–240/208 V · 3-wire2 supply circuitsFurnace alone: no LogisVert grant
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP27-A120D20
ManufacturerDettson
SeriesSuprême Avantage
Output27 kW at 240 V · 20.3 kW at 208 V
Power supply120–240/208 V, 1 ph, 60 Hz, 3-wire
MotorPSC, 1 HP, 4 speeds
Max. cooling5 tons

A 27 kW electric furnace with a PSC motor, for a 3-wire supply

Who the SUP27-A120D20 is designed for

The Dettson Suprême Avantage SUP27-A120D20 is for forced-air homes whose needs justify 27 kW, and whose electrical supply is planned at 120–240/208 V, 3-wire. It is a furnace with elements: return air passes over the electric elements, then the blower sends it through the ductwork. At 240 V it delivers 27 kW; at 208 V it delivers 20.3 kW, or 69,195 BTU/h.

The blower is driven directly by a 1 HP four-speed PSC motor. We choose the speed at installation, based on the home’s ductwork. For anyone who wants an electric furnace without unnecessary features, it is a straightforward option.

What to plan for on the electrical side

At this size, Dettson splits the supply over two terminal blocks, so two breakers: no more than 70 A for block 1 and 90 A for block 2 at 240 V (60 A and 80 A at 208 V). The published total current is 125.1 A at 240 V, and both copper and aluminum wire are approved. In a home in Laval or on the North Shore that is replacing an old furnace, we first check that the electrical service and the panel can take these two circuits.

The breakers are mounted on the front panel, next to a continuous fan switch, a low/high power switch and a heat-demand indicator light. The cabinet is painted steel, and each element can be replaced individually when one of them needs changing.

Air conditioning and heat pump

The SUP27-A120D20 takes an air conditioner or heat pump coil of up to 5 tons, on the supply or return side. With a heat pump, one rule applies: Dettson prohibits running the elements and the heat pump at the same time, as this would cause overheating. The system must therefore be non-simultaneous, and the manufacturer offers the K03081 interface kit for the heat pump. The elements then act as backup heat.

Installation by AirGreen

AirGreen is a family business established in Montreal for more than fifteen years, with RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work. Everything starts with a free in-home estimate: heating needs, location, existing wiring. Since the furnace is multi-position and approved for zero clearance, we install it in upflow, downflow, horizontal or suspended position, depending on the space available.

We then connect the plenum to the 20 x 20 in supply opening, make the two electrical connections, set the blower speed and check the temperature rise, which Dettson places between 50 and 70 °F at 240 V. Our teams travel to Montreal, Longueuil, the South Shore and the North Shore, and you get a written quote before the work.

Next step

Ask for your free in-home estimate: we give you a written quote for the Suprême Avantage SUP27-A120D20, and financing is available.

01 · What it is for

A 27 kW electric furnace for a 3-wire supply

The SUP27-A120D20 connects at 120–240/208 V, 3-wire. Its blower is driven directly by a 1 HP four-speed PSC motor, and its elements switch on in sequence to heat the air sent through the ductwork.

  • Replacing an electric furnace where the supply is planned as 3-wire
  • Homes whose heating-needs assessment confirms a 27 kW size
  • Adding a central air conditioner or heat pump, with a coil of up to 5 tons
  • Installation in a basement, a mechanical room or suspended
4-speed PSC motorA 1 HP direct-drive motor whose speed is chosen to suit the ductwork.
Replaceable elementsEach element can be replaced individually; the elements switch on in sequence, quietly according to Dettson.
Painted steel cabinetFront-mounted breakers, with a continuous fan switch, a low/high power switch and a heat-demand indicator light.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Avantage (PSC motor)
TypeElectric furnace with elements, multi-position
Output at 240 V27 kW
Output at 208 V20.3 kW
Stage 1 output15 kW (240 V) · 11.3 kW (208 V)
Heating output at 208 V69,195 BTU/h
Power supply120–240/208 V, 1 ph, 60 Hz, 3-wire
Total current125.1 A (240 V) · 108.4 A (208 V)
Ampacity (CSA C22.2-236)Block 1: 60.6 / 52.8 A · block 2: 90.0 / 78.0 A (240 / 208 V)
Maximum breakerBlock 1: 70 / 60 A · block 2: 90 / 80 A (240 / 208 V)
MotorDirect-drive PSC, 1 HP, 4 speeds
Blower wheel12 x 9
Temperature rise50-70 °F (240 V)
Maximum cooling5 tons
Air conditioner or heat pump coilSupply or return side; simultaneous operation with the elements prohibited; K03081 interface kit
ConfigurationMulti-position: upflow (factory), downflow (DFB-SUP base on a combustible floor), horizontal left or right; suspended installation allowed
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Approved forZero clearance, mobile homes, copper or aluminum wire
Front panelPainted steel cabinet; breakers, continuous fan switch, low/high power switch, heat-demand light
Manufacturer’s warrantyParts 5 years (residential), 1 year (commercial); labour not covered
Model numberSUP27-A120D20
03 · Before installing

What to know before installing

  • 120–240/208 V single-phase, 60 Hz, 3-wire power supply.
  • Two supply circuits: terminal block 1, breaker of no more than 70 A at 240 V (60 A at 208 V); terminal block 2, breaker of no more than 90 A at 240 V (80 A at 208 V).
  • Ampacity calculated per CSA C22.2-236: 60.6 A (block 1) and 90.0 A (block 2) at 240 V; 52.8 A and 78.0 A at 208 V.
  • With a heat pump, Dettson prohibits running the elements and the heat pump at the same time, as this would cause overheating: the system must be non-simultaneous. The manufacturer offers the K03081 interface kit.
  • For downflow on a combustible floor, the furnace sits on the DFB-SUP base.
  • The furnace alone is not a heat pump: it does not qualify for the LogisVert grant.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

Why two breakers?

At 27 kW, Dettson splits the supply over two terminal blocks. Block 1 needs a breaker of no more than 70 A at 240 V and block 2, no more than 90 A at 240 V. We check that your panel can take these two circuits.

What kind of power supply is needed?

The SUP27-A120D20 connects at 120–240/208 V, 3-wire, single-phase, 60 Hz. We confirm the existing wiring during the free in-home estimate, and our team makes the connection.

Can I add a heat pump to it?

Yes, with a coil on the supply or return side, up to 5 tons. The elements and the heat pump must not run at the same time: Dettson requires a non-simultaneous system and offers the K03081 interface kit.

What does the manufacturer’s warranty cover?

Dettson covers parts for 5 years in residential use and 1 year in commercial use. Labour is not part of the manufacturer’s warranty.

Does this furnace qualify for a grant?

No. A furnace with elements installed on its own does not qualify for Hydro-Québec’s LogisVert grant: it is not a heat pump.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 3-wire 27 kW Suprême Avantage, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.