DETTSON Suprême Avantage SUP23-A240D20 Electric Furnace | 23 kW - 240V

In stock
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP23-A240D20
ManufacturerDettson
SeriesSuprême Avantage
Output23 kW (240 V) · 17.3 kW (208 V)
Airflow970 CFM heating · 2,030 CFM max.
Max. cooling5 tons
Max. breaker125 A (240 V and 208 V)

Quiet electric heat in winter, a large air reserve for summer

Two airflows, two seasons

The Dettson Suprême Avantage SUP23-A240D20 is a 23 kW electric furnace at 240 V (17.3 kW at 208 V) fitted with a 4-speed, 1 HP direct-drive PSC motor. For heating, Dettson factory-sets low speed: 970 CFM at 0.5 in w.c., with a published temperature rise of 50 to 70°F at 240 V. When summer comes, the higher speeds reach 2,030 CFM, and Dettson accepts a cooling coil of up to 5 tons.

This model therefore suits a large home, for example a two-storey house with a finished basement, that wants both electric heat and a good-sized central air conditioner, or a central heat pump. The exact air conditioner size comes from the calculation, not from the maximum allowed.

Heat pump: one rule to follow

The furnace accepts an air conditioner or heat pump coil on the supply or return side. With a heat pump, Dettson does not allow the elements and the heat pump to heat at the same time, because this would cause overheating. The thermostat, or a manufacturer accessory, alternates the two sources; Dettson also provides a K03081 heat pump interface kit. In this setup, the heat pump heats as long as it is enough and the elements take over in deep cold.

A simple electrical connection

It connects on 2-wire, single-phase 240/208 V, and a 3-wire connection for 120–208/240 V is possible with accessories. Dettson lists a total current of 102.4 A at 240 V and a 125 A maximum breaker, at 240 V as at 208 V. The breakers are mounted on the front, with the continuous-fan switch, the low/high power switch and the heat-demand light. The elements come on in sequence and can be replaced one by one.

As for placement, it is multi-position (upflow, downflow on a DFB-SUP base when the floor is combustible, horizontal left or right), can be suspended and is approved for zero clearance.

AirGreen takes care of it

A family business established in Montreal for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work. It all starts with a free on-site estimate: we calculate the heating and cooling needs, review the ducts and the panel, then give you a written quote. On installation day, we set the furnace in place, connect it to the ducts and the dedicated circuit, adjust the blower speed and check the temperature rise before explaining the controls.

Dettson covers parts for 5 years in residential use and 1 year in commercial use; labour is not covered by the manufacturer.

Let’s talk

For a project in Montreal, Laval, Longueuil, the North Shore or the South Shore, ask for your free estimate and written quote. Financing is available.

01 · What it is for

Moderate airflow for heating, a large reserve for cooling

For heating, Dettson factory-sets the 1 HP motor to low speed: 970 CFM at 0.5 in w.c. The higher speeds reach 2,030 CFM, and Dettson accepts a cooling coil of up to 5 tons.

  • Large homes that want electric heat and central air conditioning
  • Replacing an electric furnace wired at 240 V
  • Pairing with a central heat pump, alternating with the elements
  • Rooms where the furnace must lie horizontal or hang
970 CFM for heatingLow speed set at the factory, at 0.5 in w.c., with a published temperature rise of 50–70°F at 240 V.
Up to 2,030 CFMThe maximum published airflow at 0.5 in w.c., for cooling of up to 5 tons.
125 A breakerThe same maximum breaker at 240 V and 208 V, on a 2-wire supply.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Avantage
TypeElectric furnace with elements, multi-position
Output at 240 V23 kW
Output at 208 V17.3 kW (58,944 BTU/h)
First-stage output13 kW (240 V) · 9.8 kW (208 V)
Power supply240/208 V, single phase, 60 Hz, 2-wire (3-wire possible for 120–208/240 V, with accessories)
Total current102.4 A (240 V) · 88.7 A (208 V)
Ampacity123.5 A (240 V) · 107.3 A (208 V)
Maximum breaker125 A (240 V) · 125 A (208 V)
MotorDirect-drive PSC, 1 HP, 4 speeds
Blower wheel12 x 9
Heating airflow970 CFM at 0.5 in w.c. (low speed, factory setting)
Maximum airflow2,030 CFM at 0.5 in w.c.
Maximum cooling5 tons
Temperature rise50–70°F (240 V)
Front-panel controlsContinuous-fan switch, low/high power switch, heat-demand light, breakers
Heat pumpCoil on supply or return; simultaneous operation of elements and heat pump not allowed; interface kit K03081
ConfigurationUpflow (factory setting), downflow (DFB-SUP base on a combustible floor), horizontal left or right; suspended installation allowed
Approved forZero clearance, mobile homes, copper or aluminum wire
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Manufacturer warrantyParts 5 years (residential) · 1 year (commercial); labour not covered
Model numberSUP23-A240D20
03 · Before installing

What to know before installing

  • Sold alone, the furnace does not qualify for the LogisVert grant: it is not a heat pump.
  • Total current of 102.4 A at 240 V (88.7 A at 208 V) and ampacity of 123.5 A (107.3 A at 208 V): a dedicated circuit is required, 125 A maximum breaker.
  • With a heat pump, the elements and the heat pump must not heat at the same time (Dettson cites a risk of overheating); interface kit K03081.
  • The cooling coil goes on the supply or return side, up to 5 tons.
  • For downflow on a combustible floor, the DFB-SUP base is used.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

Why two different airflows?

Dettson factory-sets low speed for heating, which is 970 CFM at 0.5 in w.c. The 4-speed, 1 HP motor can reach 2,030 CFM, an airflow that is useful for cooling. We adjust the speed at commissioning.

What size of air conditioner can be connected?

Up to 5 tons, according to Dettson, with the coil on the supply or return side. The right capacity depends on the home’s calculation; we determine it during the estimate.

Is a 3-wire circuit needed?

No. The furnace connects on 2-wire 240/208 V. A 3-wire connection for 120–208/240 V is possible with accessories. The maximum breaker is 125 A.

Can the heat pump and the elements run together?

No. Dettson does not allow simultaneous operation for this model, because it would cause overheating. The thermostat or an accessory alternates the two sources.

Is there a warranty?

Dettson covers parts for 5 years in residential use and 1 year in commercial use. Labour is not covered by the manufacturer.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Heating and large-capacity cooling: the 23 kW Suprême Avantage, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.