DETTSON Suprême Avantage SUP25-A120D12 Electric Furnace | 25 kW - 240V

In stock

The 25 kW Dettson Suprême Avantage electric furnace, with a 1/3 HP PSC motor, for homes with a high heating need.

Model numberSUP25-A120D12

25 kWat 240 V (18.8 kW at 208 V)
70–85°Ftemperature rise at 240 V
1,150 CFMhigh speed, at 0.5 in w.c.
120–240/208 V · 3-wireCooling up to 3 tons150 A breaker at 240 V
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberSUP25-A120D12
ManufacturerDettson
SeriesSuprême Avantage
Output25 kW (240 V) · 18.8 kW (208 V)
Power supply120–240/208 V, 1 ph, 60 Hz, 3-wire
MotorPSC 1/3 HP, 4 speeds
Max. breaker150 A (240 V) · 125 A (208 V)

25 kW of electric heat for homes that need a lot of it

Output designed for heating

Some homes need a lot of heat: a large living area, high ceilings, original insulation, or simply a calculation that calls for it. The Dettson Suprême Avantage SUP25-A120D12 meets that need with 25 kW at 240 V, or 18.8 kW (64,070 BTU/h) at 208 V. Its elements come on in sequence, quietly, and the first stage delivers 15 kW at 240 V.

Its blower is a 4-speed, 1/3 HP direct-drive PSC motor that moves 1,150 CFM at high speed (factory setting) at 0.5 in w.c. Dettson publishes a temperature rise of 70 to 85°F at 240 V for this model: the air leaves the registers noticeably warmer than the air returning to the furnace. For cooling, the coil can go up to 3 tons, on the supply or return side. It is therefore a furnace for a home that heats a lot and cools moderately.

First of all: the electrical service

At this output, the panel is the first thing to confirm. The SUP25-A120D12 runs on a 3-wire 120–240/208 V supply. Dettson lists a total current of 110.4 A and a maximum breaker of 150 A at 240 V (125 A at 208 V). During the free estimate, we check that your electrical service can take this dedicated circuit before suggesting this model.

Day to day and with a heat pump

Like the whole Avantage series, it groups the continuous-fan switch, the low/high power switch, the heat-demand light and the breakers on the front. The elements can be replaced one by one. It installs upflow, downflow or horizontal, can be suspended and is approved for zero clearance and mobile homes.

If a heat pump is added, Dettson does not allow the elements and the heat pump to heat at the same time, because this would cause overheating; the thermostat or an accessory alternates them, and the K03081 interface kit is provided. Dettson covers parts for 5 years in residential use and 1 year in commercial use; labour is not covered by the manufacturer.

Installation by AirGreen

A family business established in Montreal for more than fifteen years, AirGreen holds RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work. After the free estimate and the written quote, our technicians install the furnace, connect it to the ducts and the dedicated circuit, set the blower speed, measure the temperature rise and explain the front-panel controls.

An electric furnace sold alone is not a heat pump and does not qualify for the LogisVert grant.

For a home in Montreal, Laval, Longueuil, the North Shore or the South Shore, ask for your free estimate. You receive a written quote, and financing is available.

01 · What it is for

Plenty of heat, modest cooling

The SUP25-A120D12 delivers 25 kW at 240 V with elements that come on in sequence and a 1/3 HP PSC blower. Its published temperature rise of 70 to 85°F and its 3-ton maximum cooling make it a fit for homes that heat a lot and cool little.

  • Homes whose heating calculation reaches 25 kW
  • Replacing an old high-output furnace
  • Supplementary central air conditioning up to 3 tons
  • 3-wire electrical services (120–240/208 V)
  • Mobile homes and zero-clearance installations
25 kW at 240 VThis model’s maximum output; 15 kW in the first stage, and 18.8 kW at 208 V.
Warm air at the registersPublished temperature rise of 70 to 85°F at 240 V.
Front-panel controls and breakersContinuous fan, low/high power, heat-demand light; elements replaceable one by one.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerDettson
SeriesSuprême Avantage
TypeElectric furnace with elements, multi-position
Output at 240 V25 kW
Output at 208 V18.8 kW (64,070 BTU/h)
First-stage output15 kW (240 V) · 11.3 kW (208 V)
Power supply120–240/208 V, single phase, 60 Hz, 3-wire
Total current110.4 A (240 V) · 95.6 A (208 V)
Ampacity133.1 A (240 V) · 115.6 A (208 V)
Maximum breaker150 A (240 V) · 125 A (208 V)
MotorDirect-drive PSC, 1/3 HP, 4 speeds
Blower wheel12 x 8
Airflow1,150 CFM at 0.5 in w.c. (high speed, factory setting)
Maximum cooling3 tons
Temperature rise70–85°F (240 V)
Front-panel controlsContinuous-fan switch, low/high power switch, heat-demand light, breakers
Heat pumpCoil on supply or return; simultaneous operation of elements and heat pump not allowed; interface kit K03081
ConfigurationUpflow (factory setting), downflow (DFB-SUP base on a combustible floor), horizontal left or right; suspended installation allowed
Approved forZero clearance, mobile homes, copper or aluminum wire
Height36 1/2 in (927 mm)
Depth22 in (559 mm)
Supply opening20 x 20 in (508 x 508 mm)
Filter1 filter, 20 x 20 in
Weight105 lb (48 kg)
Manufacturer warrantyParts 5 years (residential) · 1 year (commercial); labour not covered
Model numberSUP25-A120D12
03 · Before installing

What to know before installing

  • Sold alone, an electric furnace is not a heat pump: it does not qualify for the LogisVert grant.
  • Maximum breaker of 150 A at 240 V (125 A at 208 V), total current of 110.4 A and ampacity of 133.1 A at 240 V: panel capacity is confirmed before purchase.
  • 3-wire 120–240/208 V supply.
  • Maximum cooling of 3 tons; coil on the supply or return side.
  • With a heat pump, Dettson does not allow the elements and the heat pump to heat at the same time (overheating): a thermostat or an accessory must alternate them; interface kit K03081.
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
DETTSON
See all
06 · Questions

Frequently asked questions

What does a 70 to 85°F temperature rise mean?

It is the difference Dettson publishes, at 240 V, between the air returning to the furnace and the air it blows into the ducts. We measure it at commissioning to confirm the blower speed is set correctly.

What breaker is needed for 25 kW?

Dettson lists a maximum breaker of 150 A at 240 V and 125 A at 208 V. Total current is 110.4 A at 240 V. Your panel must be able to take this dedicated circuit; we check it during the estimate.

Can I add an air conditioner?

Yes, up to 3 tons according to Dettson, with the coil on the supply or return side.

Does it work with a heat pump?

Yes, in alternation: Dettson does not allow the elements and the heat pump to run at the same time, which would cause overheating. The manufacturer provides the K03081 heat pump interface kit.

What is Dettson’s warranty?

Parts for 5 years in residential use and 1 year in commercial use. Labour is not covered by the manufacturer.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 25 kW Suprême Avantage, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.