KINGHOME Ultra Heat R32 2-Zone Heat Pump | 36,000 BTU | Montréal, Laval, South Shore, North Shore

In stock
SKU: KM36X6O-99
36,000BTU/h · 2 heads
−30 °Cheats down to
$4,320LogisVert, indicative
ENERGY STAR® cold climateWi-Fi includedR-32Up to 4 heads
Talk to a technician · 514 316-2973
Outdoor unit KM36X6OPossible indoor models KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDIAHRI 215708444· ENERGY STAR 3798994
In short

The Kinghome Ultra Heat 2 zones 36 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 36,000 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $4,320 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 215708444
36,000BTU/h at −8 °C
−30 °Cstill heating
2 → 4heads, on the same unit
2.3COP at −8 °C
$4,320LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KM36X6O

Outdoor unit

One compressor for the whole house. It supplies up to 4 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
2
24,000BTU
23
30,000BTU
234
36,000BTU
Here34
42,000BTU
2345
48,000BTU
2345
60,000BTU
23456

Kinghome Ultra Heat 2 zones 36 000 · 2 zones

36,000 BTU/h
at −8 °C
$4,320
LogisVert

Up to 4 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 100 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.0
Scale 1 – 30
HSPF2 · seasonal heating10.0
Scale 1 – 15
EER2 · cooling in peak heat12.0
Scale 1 – 20
COP at −15 °C2.1
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

36,000 BTU/h÷ 1,000 ×$120=$4,320

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215708444). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$4,320 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

32.52 in
KM36X6ODepth 16.81 in
40.16 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
45 A max. breaker
MCA 30 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 30 A, 45 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

26
41
63
20 dB(A)3040506070
26 Reference head, lowest speed41 Reference head, highest speed63 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)36,000 BTUSheet
SEER2 (seasonal cooling efficiency)21.0AHRI
EER2 (instant cooling efficiency)12.0AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
Heating
Capacity at −8 °C36,000 BTU/h · COP 2.3Sheet
Capacity at −15 °C36,000 BTU/h · COP 2.1Sheet
Capacity at −30 °C (max.)26,200 BTU/h · COP 1.51Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product2 Zones (Double Zone)Sheet
Maximum zones4 Zones (Quad Zone)Sheet
Possible indoor modelsKW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDISheet
Indoor dimensions (W × D × H)32.87 x 7.87 x 10.83 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)353 CFMSheet
Indoor sound (reference head)26 – 41 dB(A)Sheet
Installation
Outdoor unit (W × D × H)40.16 x 16.81 x 32.52 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound63 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)30 ASheet
MOP (maximum overcurrent protection)45 ASheet
RefrigerantR-32Sheet
Wi-FiInclusSheet
Certifications and warranty
AHRI215708444AHRI
ENERGY STARYes · cold climate · ID 3798994Sheet
LogisVert grant (indicative)$4,320Sheet
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

Two large spaces to heat like a main system

Some houses only have two zones, but two large ones. A single-storey home with an open-concept layout where the kitchen, dining room and living room take up the entire front of the house. A finished basement turned into a family room with a home theatre. A ground floor open to a mezzanine. In these layouts, two small heads aren't enough, and the question is no longer just supplementary comfort: it's whether the heat pump can carry the heating of these spaces through the winter. This 36,000 BTU two-zone KINGHOME Ultra Heat R32 multi-zone heat pump is designed for that role.

We recommend it for wind-exposed houses on the North Shore and the South Shore, extended single-storey homes in Laval and houses in Montréal where a finished basement stays cold all winter despite the baseboards.

36,000 BTU delivered at -15 °C

This is what sets this model apart: it keeps its full nominal capacity down to -15 °C. According to the values listed on NEEP for this combination with wall-mounted heads (AHRI No. 215708444):

  • At -8.3 °C: 36,000 BTU/h, COP of 2.3, or 100% of nominal capacity.
  • At -15 °C: 36,000 BTU/h, COP of 2.1, still 100% of nominal capacity.
  • At -30 °C: 26,200 BTU/h, COP of 1.51, or nearly 73% of nominal capacity.

In other words, capacity doesn't drop between a mild day and a -15 °C day. For two large spaces, that's what lets the heat pump remain the main heat source for most of the winter, with the electric furnace or the baseboards serving as backup only during the most intense cold. The unit carries the ENERGY STAR cold climate designation and heats down to -30 °C.

Access to 18,000 and 24,000 BTU heads

The KM36X6O outdoor unit accepts four sizes of CHARMO multi-zone wall-mounted heads: KW09XQ19CDI (9,000 BTU), KW12XQ19CDI (12,000 BTU), KW18XQ19CDI (18,000 BTU) and KW24XQ19CDI (24,000 BTU). It's the first model in the series to offer the 24,000 BTU head. In two zones, we often combine a 24,000 BTU head in the open-concept area with a 12,000 BTU head in the basement or the primary suite: the total equals exactly the 36,000 BTU nominal capacity, and both zones can run at full output together. Two 18,000 BTU heads are another balanced option when the two spaces are similar in size.

Two zones today, up to four tomorrow

The KM36X6O can serve up to four zones. In a two-zone setup, two connections stay free on the outdoor unit. That's useful when the project is done in stages: you first take care of the two large spaces where you live, then add a head in a bedroom or an office later, without replacing the outdoor unit, if the total head capacity allows it. We choose the unit location and the line routing accordingly from the first installation.

The finished basement, a zone that deserves its own head

A finished basement is often the most neglected room in a house: cold and damp in winter, damp in summer. A dedicated head changes everything. In winter, it heats the room without relying on heat coming down from the floors above, which almost never happens. In summer, it dehumidifies and protects the finishes. We mount it high on a foundation wall or a partition, taking the joists and the ceiling height into account.

Efficiency and equipment

The system is certified at 21 SEER2, 10 HSPF2 and 12 EER2. The variable-speed rotary compressor modulates to match the demand of both heads, the electronic expansion valve regulates the refrigerant flow and smart defrost limits unnecessary defrost cycles. Each head offers vertical and horizontal auto louvres, 3D airflow, humidity control, Turbo mode and self-cleaning. Wi-Fi is included for control through the KINGHOME PLUS app or a voice assistant. The system runs on R-32 refrigerant, and the outdoor unit has MAX Guard anti-corrosion protection.

What we check before installation

A system that has to carry the heating of two large spaces calls for careful preparation. Here is what we validate during an assessment in Montréal, Laval, Longueuil, on the North Shore or the South Shore.

Electrical supply

The unit requires a 220 V supply, an MCA of 30 A and an MOP of 45 A. That's a serious electrical load: we check the capacity of the electrical service, the space in the panel and the load already connected, especially if the house is heated electrically and has an electric range, dryer and water heater. Both heads are powered by the outdoor unit, with no additional circuit.

Outdoor unit location

The unit measures 40.16 x 16.81 x 32.52 inches, and its sound level is rated at 63 dB(A). At that level, location matters: we avoid placing it near a bedroom window, a deck where you spend summer evenings or a neighbour's property line. We mount it on a sturdy wall bracket above the snow, or on a raised base when the wall isn't suitable, with free drainage for defrost water.

Piping

Each of the two heads is connected with its own pair of 1/4 and 3/8 inch lines. The basement line usually goes through the rim joist; the open-concept area line can run up inside a wall or in an exterior line cover. Both circuits are vacuumed and leak-tested before the valves are opened.

Drain

The 24,000 BTU head produces a lot of condensate in summer. Its drain has to keep a continuous slope to the outside. In the basement, gravity drainage is rarely possible: we install a condensate pump connected to an existing drain.

Certification and LogisVert assistance

Reference numbers: AHRI 215708444 and ENERGY STAR ID 3798994. This combination has an indicative LogisVert amount of $4,320, calculated according to the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted.

Why go with AirGreen

  • Salaried refrigeration technicians, with no improvised subcontracting.
  • Civil liability insurance of $5,000,000.
  • Warranty registration done by our team.
  • After-sales service that knows your installation and how it's configured.

Request your free estimate: we assess your two spaces, check your electrical service and suggest the heads that suit each one.

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 36,000 BTU/h at −8 °C, 36,000 at −15 °C and 26,200 at −30 °C.

How many heads can I connect?

Up to 4 on this outdoor unit. This product is configured for 2 heads.

How much is the LogisVert grant?

$4,320. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3798994.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 26,200 BTU/h with a COP of 1.51.

Is it noisy?

Indoors, the reference head goes down to 26 dB(A). Outdoors, 63 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $4,320Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.