KINGHOME Ultra Heat R32 2-Zone Heat Pump | 60,000 BTU | Montréal, Laval, South Shore, North Shore
The Kinghome Ultra Heat 2 zones 60 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. it delivers 41,000 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $2,050 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
2 rooms, one outdoor unit.
Figures come from the manufacturer’s data and the AHRI certification.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 6 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. The combination is chosen in the “Zones” menu.
Control
Each zone is set separately, also from your phone.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 60 % of its rated capacity.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
A grant you can calculate, not guess.
The capacity at −8 °C. $50 per 1,000 BTU/h is the rate for ENERGY STAR heat pumps (guide v1.10).
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
The outdoor unit, dimensioned
One circuit for the whole house
Published sound levels, on one scale.
We use the outdoor figure to choose where the unit goes.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
Two very large spaces, the biggest heads in the lineup
This 60,000 BTU, two-zone multi-zone heat pump is aimed at spaces the other models in the series can't serve: a cathedral-ceiling family room open to the kitchen, a fully finished basement in one open space, a showroom, a small shop with a back room, a professional office on the ground floor of a building. What sets it apart is access to the 30,000 and 36,000 BTU wall-mounted heads, which are reserved for the KM60X6O outdoor unit in the Ultra Heat lineup.
We recommend it in Montréal, Laval, Longueuil, on the North Shore and the South Shore when two large spaces need to be handled with a single outdoor unit, and cooling weighs heavily in the choice.
What you need to know first: no cold climate designation
We want to be upfront about this. This unit is ENERGY STAR certified, but it does not carry the ENERGY STAR cold climate designation, unlike the lower-capacity models in the same series. Some sales materials give this designation to the entire lineup; the official certificates say otherwise for this model. That's also why its LogisVert assistance is much more modest than that of the cold-climate certified models.
That doesn't mean the unit shuts down in winter. Its heating operating range goes down to -30 °C. But the capacity it delivers in extreme cold is proportionally lower, and that has to be factored into the design. The values listed on NEEP (AHRI No. 218389037) show it:
- At -8.3 °C: 41,000 BTU/h, with a COP of 2.58, or about 68% of the nominal capacity.
- At -15 °C: 36,400 BTU/h, with a COP of 1.9, or about 61%.
- At -30 °C: 20,000 BTU/h, with a COP of 1.25, or about 33%.
For two large spaces, the takeaway is simple: this system handles fall, spring and ordinary winter days very well, and it cools with plenty of reserve in summer. In extreme cold, backup heat has to be in place. We deal with that from the design stage rather than leaving it to chance.
The right partner: existing backup heat
The most logical setup is dual energy: the heat pump does the heating for most of the winter, and the existing system, whether baseboards, a furnace or a boiler, takes over when the outdoor temperature drops. The lineup offers a dual-energy control that links the heat pump to a thermostat and switches automatically to the backup source when the heat pump can no longer keep up. Even at -30 °C, with a COP of 1.25, the heat pump still produces more heat per unit of electricity than a baseboard.
Two heads: 24,000 and 36,000 BTU
This unit accepts the CHARMO wall-mounted heads KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDI, KW30XQ21CDI and KW36XQ21CDI, from 9,000 to 36,000 BTU. For two zones, the typical combination is a 36,000 BTU head for the larger space and a 24,000 BTU head for the second one, which adds up to the outdoor unit's 60,000 BTU. Two 30,000 BTU heads work well when both spaces are about the same.
A big head in a large space needs room in front of it to throw the air all the way to the back of the room. We put it on the longest wall, up high, facing the occupied area, never at the back of a recess. The automatic vertical and horizontal louvres spread the airflow. Wi-Fi is included: both zones can be controlled from the KINGHOME PLUS app or by voice control with Google Assistant and Amazon Alexa. Both heads always run in the same mode, heating or cooling.
In a commercial space
In a shop, an office or a showroom, the cooling load almost always dominates: lighting, equipment, customers and display windows add heat all year round. A 36,000 BTU head in the main space and a 24,000 BTU head in the back room or the office give you two independent set points, with a single unit outside, often in a back lane or a yard where space is tight. For commercial use, the manufacturer's warranty terms are shorter than for residential use; we give them to you in writing with the quote.
Efficiency ratings
The system is rated at 21 SEER2, 11.65 EER2 and 10 HSPF2, uses R-32 refrigerant, and has a twin rotary compressor and an electronic expansion valve.
What we check before the installation
The electrical supply
The unit requires a 220 V supply, an MCA of 38 A and an MOP of 40 A. That's the highest electrical demand in the series: we check the capacity of the service, the space in the panel and, in a commercial space, compatibility with the existing supply. Both heads are powered from the outdoor unit through the interconnecting cable.
Where the outdoor unit goes
The unit has a vertical format: 35.43 x 13.39 x 49.61 inches, taller than it is wide, with a sound level of 60 dB(A). That format fits well along a narrow side wall or in a building's backyard. We set it on a raised stand or a support designed for its weight, above snow level, with enough clearance for the defrost water to drain.
The piping
The connections are 1/4 and 1/2 inch, depending on the port. The high-capacity heads are connected to the outdoor unit's large-diameter ports, and each circuit is vacuumed separately.
The drains
A 36,000 BTU head produces a lot of condensate in cooling mode. Its drain needs a steady slope to the outside or to a floor drain; in a commercial space, we check access to the plumbing. A condensate pump is planned when a proper slope isn't possible.
LogisVert assistance
The indicative LogisVert amount for this system is $2,050, calculated using the LogisVert rule ($50 per 1,000 BTU/h of certified heating capacity at -8.3 °C, the rate for a unit without a cold climate designation); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The references are AHRI 218389037 and ENERGY STAR ID 4610343.
Why go with AirGreen
- Salaried refrigeration technicians, residential and light commercial.
- Civil liability insurance of $5,000,000.
- Warranty registration done for you.
- After-sales service that knows your installation.
Ask for your free estimate: we assess your two spaces, your backup heat and your electrical supply, then tell you frankly whether this model is the right choice.
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on models registered for residential use.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 41,000 BTU/h at −8 °C, 36,400 at −15 °C and 20,000 at −30 °C.
How many heads can I connect?
Up to 6 on this outdoor unit. This product is configured for 2 heads.
How much is the LogisVert grant?
$2,050. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, ID 4610343.
Down to what temperature does it heat?
Down to −30 °C. At −30 °C, it still delivers 20,000 BTU/h with a COP of 1.25.
Is it noisy?
Indoors, the reference head goes down to 26 dB(A). Outdoors, 60 dB(A): we place the unit away from bedroom windows.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
What does the warranty cover?
Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.
A multi-zone system is planned room by room. At your home.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.