KINGHOME Ultra Heat R32 3-Zone Heat Pump | 36,000 BTU | Montréal, Laval, South Shore, North Shore

In stock
SKU: KM36X6O-999
36,000BTU/h · 3 heads
−30 °Cheats down to
$4,320LogisVert, indicative
ENERGY STAR® cold climateWi-Fi includedR-32Up to 4 heads
Talk to a technician · 514 316-2973
Outdoor unit KM36X6OPossible indoor models KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDIAHRI 215708444· ENERGY STAR 3798994
In short

The Kinghome Ultra Heat 3 zones 36 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 36,000 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $4,320 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

3 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 215708444
36,000BTU/h at −8 °C
−30 °Cstill heating
3 → 4heads, on the same unit
2.3COP at −8 °C
$4,320LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KM36X6O

Outdoor unit

One compressor for the whole house. It supplies up to 4 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
2
24,000BTU
23
30,000BTU
234
36,000BTU
2Here4
42,000BTU
2345
48,000BTU
2345
60,000BTU
23456

Kinghome Ultra Heat 3 zones 36 000 · 3 zones

36,000 BTU/h
at −8 °C
$4,320
LogisVert

Up to 4 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 100 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.0
Scale 1 – 30
HSPF2 · seasonal heating10.0
Scale 1 – 15
EER2 · cooling in peak heat12.0
Scale 1 – 20
COP at −15 °C2.1
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

36,000 BTU/h÷ 1,000 ×$120=$4,320

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215708444). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone3 wall units
On the wall1 outdoor unit3 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$4,320 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

32.52 in
KM36X6ODepth 16.81 in
40.16 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
45 A max. breaker
MCA 30 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 30 A, 45 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

26
41
63
20 dB(A)3040506070
26 Reference head, lowest speed41 Reference head, highest speed63 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)36,000 BTUSheet
SEER2 (seasonal cooling efficiency)21.0AHRI
EER2 (instant cooling efficiency)12.0AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
Heating
Capacity at −8 °C36,000 BTU/h · COP 2.3Sheet
Capacity at −15 °C36,000 BTU/h · COP 2.1Sheet
Capacity at −30 °C (max.)26,200 BTU/h · COP 1.51Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product3 Zones (Triple Zone)Sheet
Maximum zones4 Zones (Quad Zone)Sheet
Possible indoor modelsKW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDISheet
Indoor dimensions (W × D × H)32.87 x 7.87 x 10.83 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)353 CFMSheet
Indoor sound (reference head)26 – 41 dB(A)Sheet
Installation
Outdoor unit (W × D × H)40.16 x 16.81 x 32.52 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound63 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)30 ASheet
MOP (maximum overcurrent protection)45 ASheet
RefrigerantR-32Sheet
Wi-FiInclusSheet
Certifications and warranty
AHRI215708444AHRI
ENERGY STARYes · cold climate · ID 3798994Sheet
LogisVert grant (indicative)$4,320Sheet
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

Three levels, three zones, a house that needs real heating

Older houses in Montréal and in the first-ring suburbs of Laval and Longueuil often have three clearly separate levels: a main living floor, an upper floor of bedrooms and a basement finished over the years. The original insulation is modest, the windows have been replaced once, and heating relies on baseboards or an old electric furnace. In this kind of house, a heat pump isn't just there to cool in summer: it's expected to carry a real share of the winter heating. This KINGHOME Ultra Heat R32 36,000 BTU three-zone multi-zone heat pump puts one head on each level, with the reserve capacity that a house losing heat calls for.

We also recommend it for corner houses and more isolated properties on the North Shore and South Shore, which are more exposed to wind than attached houses.

One head per level

The KM36X6O outdoor unit accepts the CHARMO multi-zone wall-mounted heads KW09XQ19CDI (9,000 BTU), KW12XQ19CDI (12,000 BTU), KW18XQ19CDI (18,000 BTU) and KW24XQ19CDI (24,000 BTU). For a three-level house, the layout we choose most often is the following:

  1. Ground floor: an 18,000 or 24,000 BTU head, depending on how open the living area is and how much glazing it has.
  2. Upper floor: a 12,000 BTU head on the landing or in the primary bedroom, where summer heat builds up.
  3. Basement: a 9,000 or 12,000 BTU head, which heats in winter and dehumidifies in summer.

With a 24,000 BTU head on the ground floor, 12,000 BTU upstairs and 9,000 BTU in the basement, the total comes to 45,000 BTU. Going over the nominal capacity like this is common in multi-zone systems, because the three levels don't call for their maximum at the same time. The variable-speed compressor and the electronic expansion valve distribute refrigerant according to each head's demand.

Capacity that doesn't drop before -15 °C

In a house that loses heat, what matters is the capacity delivered in deep cold. The values listed on NEEP for this combination with wall-mounted heads (AHRI No. 215708444):

  • 36,000 BTU/h at -8.3 °C, COP of 2.3.
  • 36,000 BTU/h at -15 °C, COP of 2.1: the full nominal capacity is still available.
  • 26,200 BTU/h at -30 °C, COP of 1.51, or nearly 73% of nominal capacity, at the heating operating limit.

That's why we steer more energy-hungry houses toward this model rather than a lower-capacity three-zone unit: the difference doesn't show in October, it shows during the first week at -15 °C. The heat pump then remains the main heating source, and the electric furnace or baseboards only kick in as backup. The unit carries the ENERGY STAR cold climate designation.

The basement, often the most cost-effective zone

In an older house, the basement is cold in winter and damp in summer. Heat from the ground floor never makes it down there. A dedicated head makes it livable year-round, protects the finishes and cuts down on the use of a portable dehumidifier. We mount it high on a wall, away from the joists and existing duct bulkheads, so the airflow covers the whole room.

Efficiency and features

The system is certified at 21 SEER2, 10 HSPF2 and 12 EER2. Each head offers automatic vertical and horizontal louvres, 3D airflow, humidity control, Turbo mode, self-cleaning and R-32 refrigerant leak detection. Wi-Fi is included: the three levels are adjusted separately in the KINGHOME PLUS app or by voice command. The outdoor unit is equipped with a heater in the base pan for defrost water, smart defrost and MAX Guard anti-corrosion protection.

What we check before installation

An older house often holds surprises. Here are the points we confirm during an assessment in Montréal, Laval, Longueuil, on the North Shore or the South Shore.

The electrical service

The system requires a 220 V supply, a 30 A MCA and a 45 A MOP. The three heads are powered by the outdoor unit. In an older house, this is the first thing we check: service capacity, panel condition, available space and the load of the baseboards and furnace already connected. If an upgrade is needed, we say so in the quote, not after the work is done.

Outdoor unit location

The unit measures 40.16 x 16.81 x 32.52 inches and its sound level is rated at 63 dB(A). On a street where houses are close together, we place it away from bedroom windows, yours as well as the neighbours'. It is mounted on a wall bracket above the snow line, sheltered from snow sliding off the roof, with free drainage for defrost water.

Three levels of line sets

Each head is connected by its own pair of 1/4 and 3/8 inch lines. The upper-floor line is the longest and the highest; the basement line goes through the foundation or the rim joist. We check the height difference between the outdoor unit and each head, group the lines in a line-set cover, and pull a vacuum and run a leak test on every circuit.

Drains

The ground-floor and upper-floor heads usually drain outside by gravity. In the basement, we install a condensate pump connected to an existing drain.

Certification and LogisVert assistance

Reference numbers: AHRI 215708444 and ENERGY STAR ID 3798994. This combination has an indicative LogisVert amount of $4,320, calculated with the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted.

Why go with AirGreen

  • Salaried refrigeration technicians used to older houses and their quirks.
  • $5,000,000 in civil liability insurance.
  • Warranty registration handled by us at commissioning.
  • After-sales service that knows all three of your levels.

Request your free estimate: we assess each level, check your electrical service and give you a clear quote for the whole house.

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered units.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 36,000 BTU/h at −8 °C, 36,000 at −15 °C and 26,200 at −30 °C.

How many heads can I connect?

Up to 4 on this outdoor unit. This product is configured for 3 heads.

How much is the LogisVert grant?

$4,320. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3798994.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 26,200 BTU/h with a COP of 1.51.

Is it noisy?

Indoors, the reference head goes down to 26 dB(A). Outdoors, 63 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $4,320Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.