KINGHOME Ultra Heat R32 4-Zone Heat Pump | 30,000 BTU | Montréal, Laval, South Shore, North Shore
The Kinghome Ultra Heat 4 zones 30 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 28,000 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $3,360 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
4 rooms, one outdoor unit.
Figures come from the manufacturer’s data and the AHRI certification.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 4 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. The combination is chosen in the “Zones” menu.
Control
Each zone is set separately, also from your phone.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 90 % of its rated capacity.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
A grant you can calculate, not guess.
The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
The outdoor unit, dimensioned
One circuit for the whole house
Published sound levels, on one scale.
We use the outdoor figure to choose where the unit goes.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
Four closed rooms, four set points, a single unit outside
Some houses don't lend themselves to one or two wall-mounted heads. That's the case for single-family houses divided into closed rooms: a living room, two or three bedrooms along a hallway, a home office. Air from a head in the living room doesn't turn the corner into the hallway, and every closed door becomes a barrier. For these layouts, the answer is one head per room. This 30,000 BTU, four-zone KINGHOME Ultra Heat R32 multi-zone heat pump connects four wall-mounted heads to a single outdoor unit, so you don't end up with four compressors lined up along the outside wall.
We mainly recommend it to replace full baseboard heating in houses in Laval, Longueuil, the North Shore and the South Shore, and in houses in Montréal where the outdoor space only allows one unit.
One outdoor unit instead of four
Four separate wall-mounted heat pumps mean four outdoor units, four brackets, four wall penetrations, four circuits at the panel and four units to maintain. Several municipalities also regulate the placement and number of units visible from the street. The four-zone version puts everything on a single compressor: one unit to place, one electrical circuit, and lines that can be grouped in the same line cover. For a front facade or a narrow yard, the difference is considerable.
Splitting 30,000 BTU properly among four rooms
With four zones on a 30,000 BTU unit, choosing the heads becomes central. The KM30X6O unit accepts the CHARMO multi-zone wall-mounted heads KW09XQ19CDI (9,000 BTU), KW12XQ19CDI (12,000 BTU) and KW18XQ19CDI (18,000 BTU). In a house with closed rooms, we favour the small sizes: a 12,000 BTU head in the living room and three 9,000 BTU heads in the bedrooms and the office, for a total of 39,000 BTU. The 18,000 BTU head is kept for when one of the four zones is a true open area.
Going over the nominal capacity like this is normal: four rooms never all call for their maximum at the same time. At night, the living room and the office are idle and the bedrooms get most of the refrigerant; during the day, it's the reverse. The variable-speed compressor and the electronic expansion valve handle this distribution continuously.
The home office, a zone of its own
Working from home has changed the way we heat a house. The office is occupied all day while the bedrooms are empty, then the reverse in the evening. With a dedicated zone, the office stays comfortable without heating or cooling the rest of the house. With Wi-Fi included, each zone can be scheduled separately in the KINGHOME PLUS app, and voice control works with Google Assistant and Amazon Alexa.
Published winter capacities
The values listed on NEEP (AHRI No. 215708443) for this combination with wall-mounted heads are as follows:
- -8.3 °C: 28,000 BTU/h, COP of 2.45.
- -15 °C: 27,000 BTU/h, COP of 2.07.
- -30 °C: 21,000 BTU/h, COP of 1.45, the heating operating limit.
Compared with baseboards, which give one kilowatt-hour of heat per kilowatt-hour used, the heat pump delivers more than double at -15 °C. The existing baseboards stay connected as backup: they only take over in a room that drops below its set point in extreme cold. The unit carries the ENERGY STAR cold climate designation and is rated at 21 SEER2, 10 HSPF2 and 13.6 EER2.
Summer comfort in every bedroom
A house with closed rooms is also the one that's hardest to cool with a single unit. With one head per room, each bedroom is cooled and dehumidified independently. The 9,000 BTU head is rated at 26 to 41 dB(A), quiet enough to forget it's there at night. Automatic vertical and horizontal louvres, 3D airflow, self-cleaning and R-32 refrigerant leak detection round out the features.
What we check before the installation
Four heads on a single unit take more preparation than a simple installation. Here's what we confirm during an assessment in Montréal, Laval, Longueuil, on the North Shore or the South Shore.
The electrical supply
The unit requires 220 V, an MCA of 23 A and an MOP of 35 A. All four heads are powered by the outdoor unit. One circuit for four rooms, where four separate units would need four circuits: in a panel already loaded with baseboards, that's often what avoids having to upgrade the electrical service.
Where the outdoor unit goes
The unit measures 40.16 x 16.81 x 32.52 inches and its sound level is 58 dB(A). We mount it on a wall bracket anchored into the structure, above the snow and away from snow falling off the roof, on a wall where the four sets of lines can come together without crossing the whole exterior.
Four sets of lines
Each head has its own pair of 1/4 and 3/8 inch lines. We group the routes as much as possible, through the basement, the attic or a shared line cover, and we label each line at the outdoor unit so every connection matches the right room. A crossed connection gives you a bedroom that heats when you ask for the living room: it's a mistake we often correct on multi-zone installations done by others. Vacuum and leak test on all four circuits.
Four drains
Each head has its own drain. Those in rooms on an exterior wall drain directly outside; for a head on an interior wall, we install a condensate pump. The slope of each drain is checked before the line covers are closed.
Certification and LogisVert assistance
Reference numbers: AHRI 215708443 and ENERGY STAR ID 3798993. The indicative LogisVert amount for this combination is $3,360, calculated using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted.
Why go with AirGreen
- Salaried refrigeration technicians who label and test every zone before they leave.
- Civil liability insurance of $5,000,000.
- Warranty registration handled by our team.
- After-sales service that keeps the map of your four zones on file.
Ask for your free estimate: we visit every room, place the heads to suit your habits and give you a complete quote for the whole house.
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 28,000 BTU/h at −8 °C, 27,000 at −15 °C and 21,000 at −30 °C.
How many heads can I connect?
Up to 4 on this outdoor unit. This product is configured for 4 heads.
How much is the LogisVert grant?
$3,360. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, cold climate, ID 3798993.
Down to what temperature does it heat?
Down to −30 °C. At −30 °C, it still delivers 21,000 BTU/h with a COP of 1.45.
Is it noisy?
Indoors, the reference head goes down to 26 dB(A). Outdoors, 58 dB(A): we place the unit away from bedroom windows.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
What does the warranty cover?
Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.
A multi-zone system is planned room by room. At your home.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.