KINGHOME Ultra Heat R32 3-Zone Heat Pump | 24,000 BTU | Montréal, Laval, South Shore, North Shore

In stock
SKU: KM24X6O-999
24,000BTU/h · 3 heads
−30 °Cheats down to
$2,832LogisVert, indicative
ENERGY STAR® cold climateWi-Fi includedR-32Up to 3 heads
Talk to a technician · 514 316-2973
Outdoor unit KM24X6OPossible indoor models KW09XQ19CDI, KW12XQ19CDIAHRI 215708442· ENERGY STAR 3798992
In short

The Kinghome Ultra Heat 3 zones 24 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 23,600 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $2,832 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

3 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 215708442
23,600BTU/h at −8 °C
−30 °Cstill heating
3heads
2.45COP at −8 °C
$2,832LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KM24X6O

Outdoor unit

One compressor for the whole house. It supplies up to 3 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
2
24,000BTU
2Here
30,000BTU
234
36,000BTU
234
42,000BTU
2345
48,000BTU
2345
60,000BTU
23456

Kinghome Ultra Heat 3 zones 24 000 · 3 zones

23,600 BTU/h
at −8 °C
$2,832
LogisVert

Up to 3 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 90 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.0
Scale 1 – 30
HSPF2 · seasonal heating10.0
Scale 1 – 15
EER2 · cooling in peak heat13.3
Scale 1 – 20
COP at −15 °C2.0
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

23,600 BTU/h÷ 1,000 ×$120=$2,832

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215708442). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone3 wall units
On the wall1 outdoor unit3 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$2,832 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

25.98 in
KM24X6ODepth 15.83 in
37.95 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
25 A max. breaker
MCA 20 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 20 A, 25 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

26
41
58
20 dB(A)3040506070
26 Reference head, lowest speed41 Reference head, highest speed58 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)24,000 BTUSheet
SEER2 (seasonal cooling efficiency)21.0AHRI
EER2 (instant cooling efficiency)13.3AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
Heating
Capacity at −8 °C23,600 BTU/h · COP 2.45Sheet
Capacity at −15 °C21,600 BTU/h · COP 2.0Sheet
Capacity at −30 °C (max.)17,400 BTU/h · COP 1.5Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product3 Zones (Triple Zone)Sheet
Maximum zones3 Zones (Triple Zone)Sheet
Possible indoor modelsKW09XQ19CDI, KW12XQ19CDISheet
Indoor dimensions (W × D × H)32.87 x 7.87 x 10.83 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)353 CFMSheet
Indoor sound (reference head)26 – 41 dB(A)Sheet
Installation
Outdoor unit (W × D × H)37.95 x 15.83 x 25.98 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound58 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)20 ASheet
MOP (maximum overcurrent protection)25 ASheet
RefrigerantR-32Sheet
Wi-FiInclusSheet
Certifications and warranty
AHRI215708442AHRI
ENERGY STARYes · cold climate · ID 3798992Sheet
LogisVert grant (indicative)$2,832Sheet
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

The bungalow that turns the page on baseboards

The single-storey bungalow is still the most common house in Laval, on the South Shore and in several neighbourhoods in the east end of Montréal. Most are heated with electric baseboards, room by room, and have never had central air for lack of ducts. The owner wants to lower the winter bill, gain real comfort in summer and avoid tearing open the ceilings to install a duct system. This three-zone 24,000 BTU KINGHOME Ultra Heat R32 multi-zone heat pump is designed for that scenario: one head in the living room, one head in each of the two main bedrooms, and a single outdoor unit behind the house.

Three zones is the maximum number of heads the KM24X6O outdoor unit can serve. This product therefore uses all of its connection capacity, which calls for a well-thought-out head layout.

Thinking like baseboards, room by room

What homeowners like about their baseboards is having a thermostat in every room. The multi-zone heat pump keeps that logic. Each wall-mounted head has its own set point, its own remote and its own control in the KINGHOME PLUS app thanks to the included Wi-Fi. The kids' room can stay warm at night, the primary bedroom cooler, and the living room can switch to economy mode during the workday.

The difference shows on the bill. A baseboard turns one kilowatt-hour into one kilowatt-hour of heat. This heat pump has a COP of 2.45 at -8.3 °C and 2.0 at -15 °C: at those temperatures, it delivers twice the heat or more for the same electricity. The baseboards don't disappear, though. We leave them in place as backup heat for the most extreme nights and for rooms without a head, such as the bathroom.

Choosing the three heads

The outdoor unit accepts two sizes of CHARMO multi-zone wall-mounted heads: the 9,000 BTU KW09XQ19CDI and the 12,000 BTU KW12XQ19CDI. In a typical bungalow, we put a 12,000 BTU head in the living room and kitchen area and two 9,000 BTU heads in the bedrooms. The total, 30,000 BTU, exceeds the outdoor unit's nominal capacity of 24,000 BTU, and that's intentional: three rooms never call for their maximum at the same time. The variable-speed compressor and the electronic expansion valve distribute the refrigerant according to each head's actual demand.

The third bedroom, often turned into an office, is handled by leaving its door open to the hallway or by keeping its baseboard. We prefer this approach to adding an oversized head: a head that's too big for a small room keeps starting and stopping, dehumidifies poorly in summer and wears out the system for nothing.

The winter figures listed on NEEP

According to the values listed on NEEP for this combination with wall-mounted heads (AHRI No. 215708442):

  • 23,600 BTU/h at -8.3 °C, with a COP of 2.45.
  • 21,600 BTU/h at -15 °C, with a COP of 2.0, or 90% of nominal capacity.
  • 17,400 BTU/h at -30 °C, with a COP of 1.5, the lower heating operating limit.

For a well-maintained bungalow, these values cover the vast majority of the year's heating hours. The unit carries the ENERGY STAR cold climate designation. Its seasonal efficiency is 21 SEER2 in cooling and 10 HSPF2 in heating, with an EER2 of 13.3 on hot days.

What you gain in summer

A bungalow without central air often makes do with a window air conditioner in one bedroom. With three zones, summer becomes even throughout: the living room and both bedrooms are cooled, with no compressor noise inside the house. The automatic vertical and horizontal louvre, the 3D airflow and each head's humidity control keep the air dry without a direct draft. The heads also offer self-cleaning and R-32 refrigerant leak detection.

What we check before installation

A bungalow looks simple, but three heads connected to a single unit call for method. Here's what we confirm during our assessments in Montréal, Laval, Longueuil, on the North Shore and the South Shore.

The electrical panel

The system requires a 220 V supply, an MCA of 20 A and an MOP of 25 A. The three heads are powered by the outdoor unit: a single circuit serves the whole house. In a bungalow heated with baseboards, the original panel is often quite full. We review the existing load before confirming, to avoid an unexpected electrical service upgrade.

The outdoor unit behind the house

The unit measures 37.95 x 15.83 x 25.98 inches and produces 58 dB(A). We set it on a wall bracket at the back or on the side, above snow level and away from downspouts and snow sliding off the roof. On a bungalow, the roof often dumps snow right along the walls: a poorly chosen spot buries the unit at the first thaw.

Three piping runs

Each head gets its own pair of lines, 1/4 and 3/8 inch. In a bungalow, we often use the crawl space or the basement to run the bedroom lines without anything showing on the front of the house. Each of the three circuits is vacuumed before start-up.

Condensate drains

Three heads, three drains. Each one needs to keep a continuous slope toward the outside or toward a floor drain in the basement. For a head mounted on an interior wall, we install a quiet condensate pump.

Certification and LogisVert grant

Reference numbers: AHRI 215708442 and ENERGY STAR ID 3798992. This combination has an indicative LogisVert amount of $2,832, calculated according to the LogisVert rule ($120 per 1,000 BTU/h of certified heating at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. For a switch from baseboards to a heat pump, that's a significant share of the project.

Why choose AirGreen

  • Salaried refrigeration technicians, no subcontracting.
  • Civil liability insurance of $5,000,000.
  • Warranty registration done by us at start-up.
  • After-sales service that knows each of your three zones.

Request your free estimate: we go through the rooms, check your electrical panel and propose the head layout that suits your bungalow.

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 23,600 BTU/h at −8 °C, 21,600 at −15 °C and 17,400 at −30 °C.

How many heads can I connect?

Up to 3 on this outdoor unit. This product is configured for 3 heads.

How much is the LogisVert grant?

$2,832. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3798992.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 17,400 BTU/h with a COP of 1.5.

Is it noisy?

Indoors, the reference head goes down to 26 dB(A). Outdoors, 58 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $2,832Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.