KINGHOME Ultra Heat R32 5-Zone Heat Pump | 48,000 BTU | Montréal, Laval, South Shore, North Shore

In stock
SKU: KM48X6O-99999
48,000BTU/h · 5 heads
−30 °Cheats down to
$5,340LogisVert, indicative
ENERGY STAR® cold climateWi-Fi includedR-32Up to 5 heads
Talk to a technician · 514 316-2973
Outdoor unit KM48X6OPossible indoor models KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDIAHRI 216772301· ENERGY STAR 3995741
In short

The Kinghome Ultra Heat 5 zones 48 000 multi-zone heat pump heats and cools 5 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 44,500 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $5,340 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

5 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 216772301
44,500BTU/h at −8 °C
−30 °Cstill heating
5heads
2.4COP at −8 °C
$5,340LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KM48X6O

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
2
24,000BTU
23
30,000BTU
234
36,000BTU
234
42,000BTU
2345
48,000BTU
234Here
60,000BTU
23456

Kinghome Ultra Heat 5 zones 48 000 · 5 zones

44,500 BTU/h
at −8 °C
$5,340
LogisVert

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 78 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.0
Scale 1 – 30
HSPF2 · seasonal heating10.0
Scale 1 – 15
EER2 · cooling in peak heat12.0
Scale 1 – 20
COP at −15 °C2.1
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

44,500 BTU/h÷ 1,000 ×$120=$5,340

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 216772301). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone5 wall units
On the wall1 outdoor unit5 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$5,340 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

32.52 in
KM48X6ODepth 16.81 in
40.16 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
45 A max. breaker
MCA 30 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Head 4
Head 5
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 30 A, 45 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

26
41
69
20 dB(A)3040506070
26 Reference head, lowest speed41 Reference head, highest speed69 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)48,000 BTUSheet
SEER2 (seasonal cooling efficiency)21.0AHRI
EER2 (instant cooling efficiency)12.0AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
Heating
Capacity at −8 °C44,500 BTU/h · COP 2.4Sheet
Capacity at −15 °C37,800 BTU/h · COP 2.1Sheet
Capacity at −30 °C (max.)28,400 BTU/h · COP 1.5Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product5 ZonesSheet
Maximum zones5 ZonesSheet
Possible indoor modelsKW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDISheet
Indoor dimensions (W × D × H)32.87 x 7.87 x 10.83 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)353 CFMSheet
Indoor sound (reference head)26 – 41 dB(A)Sheet
Installation
Outdoor unit (W × D × H)40.16 x 16.81 x 32.52 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound69 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)30 ASheet
MOP (maximum overcurrent protection)45 ASheet
RefrigerantR-32Sheet
Wi-FiInclusSheet
Certifications and warranty
AHRI216772301AHRI
ENERGY STARYes · cold climate · ID 3995741Sheet
LogisVert grant (indicative)$5,340Sheet
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

A large house on a single electrical circuit

In a large house heated with baseboards, the constraint that most often blocks a heat pump project isn't wall space or budget: it's the electrical panel. Between the baseboards, the range, the dryer, the water heater and sometimes an EV charger, there's often little capacity left. This five-zone 48,000 BTU multi-zone heat pump was chosen for these houses: five rooms served, a single outdoor unit, and a single circuit at the panel.

We install it in large single-family homes in Laval, on the North Shore and on the South Shore, and in houses in Montréal and Longueuil with four or more bedrooms, often with a home office that's in use all day.

What five zones ask of the panel

The KM48X6O outdoor unit requires a 220 V supply, a minimum circuit ampacity (MCA) of 30 A and a maximum overcurrent protection (MOP) of 45 A. The five heads are powered through the interconnect cable from the outdoor unit, with no circuit of their own. Five independent wall-mounted heat pumps would need five separate circuits at the panel, each with its own breaker and outdoor disconnect.

Before confirming the quote, we do a load calculation for your electrical service entrance. A heat pump that takes over from the baseboards cuts their demand for most of the winter, but the calculation has to be done by the rules, taking every appliance in the house into account. If the service needs to be upgraded, we tell you when we give you the quote.

Five heads and how the capacity is split

The compatible CHARMO wall-mounted heads are the KW09XQ19CDI (9,000 BTU), KW12XQ19CDI (12,000 BTU), KW18XQ19CDI (18,000 BTU) and KW24XQ19CDI (24,000 BTU). A typical five-zone layout is a 12,000 BTU head for the living room and four 9,000 BTU heads for the bedrooms and the office, which adds up to the outdoor unit's 48,000 BTU.

The strength of a multi-zone system this size is splitting capacity according to how each room is used. The home office needs heat during the day and nothing in the evening; the bedrooms, the opposite; the living room, mostly in the evening. The variable-speed compressor and the electronic expansion valves send refrigerant to the heads that are calling for it, when they call for it. A zone that's turned off uses nothing. Each head has its own set point, and Wi-Fi is included: all five zones can be scheduled in the KINGHOME PLUS app, or controlled by voice with Google Assistant and Amazon Alexa. All zones run in the same mode at any given time, heating or cooling.

The home office

The office deserves special attention. Computers, screens and lighting give off heat all day, and the room is often the smallest in the house. The result: it overheats in spring and fall while the rest of the house is comfortable. With a zone of its own, the office head can slow down or stop while the other rooms keep getting heat, and in the shoulder season, when the rest of the house needs nothing, the office can be cooled on its own. Keep in mind that all zones share the same mode: the office can't be cooling while the bedrooms are heating. When the office is in the basement, it actually needs a little more heat in winter, and the head is sized accordingly after the on-site assessment of heating needs.

Reading the winter numbers for a large house

  • At -8.3 °C: 44,500 BTU/h, COP of 2.4.
  • At -15 °C: 37,800 BTU/h, COP of 2.1, or about 79% of nominal capacity.
  • At -30 °C: 28,400 BTU/h, COP of 1.5, or about 59% of nominal capacity; this is the heating operating limit.

These values are listed on NEEP (AHRI No. 216772301) for ductless heads, and the unit carries the ENERGY STAR cold climate designation. In a large house, the capacity available in extreme cold is shared among five rooms, so we always keep the baseboards in place as backup. They only come on when the heat pump can no longer hold the set point, which limits their use to extreme cold spells. You should also know that in heating, this model's published values are the same as those of the next size down in the series; its advantage is in cooling, which is useful in a large house with several sunny rooms.

Efficiency ratings

The system has a SEER2 of 21, an EER2 of 12 and an HSPF2 of 10, with R-32 refrigerant. The range includes refrigerant leak protection, with an alarm and outdoor unit shutdown, as well as smart defrost that cuts down on unnecessary cycles in winter.

What we check before installing five zones

The on-site assessment of heating needs

Five heads aren't chosen by square footage. We assess each room: orientation, windows, insulation, occupancy. A head that's too big for a small bedroom takes a share of capacity the other rooms need, and it dehumidifies poorly in summer.

Location and sound level

The unit measures 40.16 x 16.81 x 32.52 inches and produces 69 dB(A). On a large lot, we usually have a choice of location: away from the bedrooms, the patio and the property line. The unit goes on a wall bracket or a raised pad, above the snow, with vibration isolators, and defrost water drains away from the walkways.

Five pairs of lines

Each head has its own pair of 1/4 and 3/8 inch lines. We plan the route to group the lines under as few line covers as possible and keep the runs short. Each circuit is vacuumed separately, and port and cable identification is checked zone by zone at startup.

Five drains

Each head has its own condensate drain. We favour gravity drainage on exterior walls, and a condensate pump is planned for any head mounted on an interior wall. This detail is spelled out in the quote, head by head.

LogisVert assistance

This system has an indicative LogisVert amount of $5,340, calculated according to the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The references are AHRI 216772301 and ENERGY STAR ID 3995741.

Why go with AirGreen

  • Salaried refrigeration technicians who are used to large multi-zone systems.
  • Civil liability insurance of $5,000,000.
  • Warranty registration taken care of.
  • After-sales service that keeps the plan of your five zones on file.

Request your free estimate: we check your electrical panel, assess your five rooms and give you a detailed quote, with no surprises.

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 44,500 BTU/h at −8 °C, 37,800 at −15 °C and 28,400 at −30 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 5 heads.

How much is the LogisVert grant?

$5,340. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3995741.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 28,400 BTU/h with a COP of 1.5.

Is it noisy?

Indoors, the reference head goes down to 26 dB(A). Outdoors, 69 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $5,340Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.