Outdoor unit KM48X6OPossible indoor models KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDIAHRI 216772301· ENERGY STAR 3995741
In short

The Kinghome Ultra Heat 2 zones 48 000 multi-zone heat pump heats and cools 2 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 44,500 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $5,340 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

2 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 216772301
44,500BTU/h at −8 °C
−30 °Cstill heating
2 → 5heads, on the same unit
2.4COP at −8 °C
$5,340LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KM48X6O

Outdoor unit

One compressor for the whole house. It supplies up to 5 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
2
24,000BTU
23
30,000BTU
234
36,000BTU
234
42,000BTU
2345
48,000BTU
Here345
60,000BTU
23456

Kinghome Ultra Heat 2 zones 48 000 · 2 zones

44,500 BTU/h
at −8 °C
$5,340
LogisVert

Up to 5 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 78 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.0
Scale 1 – 30
HSPF2 · seasonal heating10.0
Scale 1 – 15
EER2 · cooling in peak heat12.0
Scale 1 – 20
COP at −15 °C2.1
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

44,500 BTU/h÷ 1,000 ×$120=$5,340

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 216772301). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone2 wall units
On the wall1 outdoor unit2 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$5,340 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

32.52 in
KM48X6ODepth 16.81 in
40.16 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
45 A max. breaker
MCA 30 A · 220 V
Outdoor unit
Head 1
Head 2
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 30 A, 45 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

26
41
69
20 dB(A)3040506070
26 Reference head, lowest speed41 Reference head, highest speed69 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)48,000 BTUSheet
SEER2 (seasonal cooling efficiency)21.0AHRI
EER2 (instant cooling efficiency)12.0AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
Heating
Capacity at −8 °C44,500 BTU/h · COP 2.4Sheet
Capacity at −15 °C37,800 BTU/h · COP 2.1Sheet
Capacity at −30 °C (max.)28,400 BTU/h · COP 1.5Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product2 Zones (Double Zone)Sheet
Maximum zones5 ZonesSheet
Possible indoor modelsKW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDISheet
Indoor dimensions (W × D × H)32.87 x 7.87 x 10.83 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)353 CFMSheet
Indoor sound (reference head)26 – 41 dB(A)Sheet
Installation
Outdoor unit (W × D × H)40.16 x 16.81 x 32.52 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound69 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)30 ASheet
MOP (maximum overcurrent protection)45 ASheet
RefrigerantR-32Sheet
Wi-FiInclusSheet
Certifications and warranty
AHRI216772301AHRI
ENERGY STARYes · cold climate · ID 3995741Sheet
LogisVert grant (indicative)$5,340Sheet
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

Two zones with a heavy cooling load

This two-zone 48,000 BTU multi-zone heat pump is meant for a specific situation: two large spaces that suffer mostly from the heat. A full top floor under the eaves that gets unbearably hot in July, an open-plan area with a picture window or a south-facing patio door, a room with a cathedral ceiling and skylights. In these houses, it's cooling that sets the size of the equipment, and that's why we choose the KM48X6O outdoor unit rather than the lower-capacity model in the same range.

We install this configuration in houses in Laval, on the North Shore and on the South Shore where the top floor was built into the attic, and in houses in Montréal and Longueuil renovated into an open plan with large glass areas.

What the 48,000 BTU brings, and what it doesn't

We'd rather be upfront about something few sellers mention. The heating capacities listed on NEEP (AHRI No. 216772301) for this unit at -8.3 °C, -15 °C and -30 °C are identical to those of the lower-capacity model in the same series. The gain with the 48,000 BTU is in cooling, with a higher nominal capacity for large sun-exposed areas. If your house is mainly hard to heat, rather than to cool, we'll suggest the other model.

Two 24,000 BTU heads

This unit accepts the CHARMO wall-mounted heads KW09XQ19CDI (9,000 BTU), KW12XQ19CDI (12,000 BTU), KW18XQ19CDI (18,000 BTU) and KW24XQ19CDI (24,000 BTU). For two zones this size, the natural combination is two 24,000 BTU heads, which add up to the outdoor unit's 48,000 BTU. One head for the floor under the roof, one for the open-plan area on the ground floor. When one of the two zones is smaller, an 18,000 BTU head can take its place; the on-site assessment of heating and cooling needs, room by room, makes the call.

Each head has its own remote and set point. Wi-Fi is included: you can start cooling the top floor from the KINGHOME PLUS app an hour before bedtime, or by voice with Google Assistant and Amazon Alexa.

Why not a central ducted system

In a house heated with baseboards or hot water, there's no duct system at all. Installing one for a floor under the eaves means opening ceilings, giving up closets and running ducts through an attic that's already very hot in summer, where they lose part of their cool air before it even reaches the grilles. Two ductless wall-mounted heads avoid that work: only two pairs of lines and one cable go through the walls, and each head cools the room's air directly. For a homeowner who wants to fix the heat upstairs without turning the house into a construction site, it's usually the most direct solution.

Efficiency in peak heat

The system has a SEER2 of 21, which measures efficiency over the whole season, and an EER2 of 12, which measures efficiency during the hottest hours. For a floor under the eaves, it's the EER2 that counts: that's when the head runs at full output. The heads dehumidify while they cool, and a properly sized head removes more humidity than an oversized one that reaches the set point too quickly.

Winter, figures listed on NEEP

  • At -8.3 °C: 44,500 BTU/h, COP of 2.4, or about 93% of nominal capacity.
  • At -15 °C: 37,800 BTU/h, COP of 2.1, or about 79%.
  • At -30 °C: 28,400 BTU/h, COP of 1.5, the heating operating limit.

The unit carries the ENERGY STAR cold climate designation and an HSPF2 of 10. A COP of 2.1 means it delivers a little more than twice the energy it uses, while an electric baseboard gives back one for one. The existing heating stays in place as backup for the coldest nights. Both heads share the same compressor: they both run in the same mode, heating or cooling.

What we check before installation

Electrical supply

The outdoor unit requires a 220 V supply, an MCA of 30 A and an MOP of 45 A. Both heads are powered through the interconnect cable from the outdoor unit, on a single circuit in the panel. We check the capacity of the electrical service before the quote.

Sound level and location

This is the point to watch with this model: the outdoor unit is rated at 69 dB(A), more than the lower-capacity model in the range. It measures 40.16 x 16.81 x 32.52 inches. We keep it away from bedroom windows, the deck and the property line, and we take into account municipal noise bylaws, which vary from one city and borough to the next. It's set on a wall bracket or a raised pad, above snow level, with vibration isolators, and defrost water must drain without freezing on a walkway.

Lines to the top floor

Each head has its own pair of lines, 1/4 and 3/8 inch. For the floor under the eaves, we run the lines under line covers on the outside wall or through the attic; in the latter case, they're insulated along their full length to prevent condensation in summer. Each circuit is vacuumed separately.

Drains

A 24,000 BTU head cooling a hot top floor produces a lot of condensate. The drain must keep a steady slope toward the outside; when the layout doesn't allow it, we install a condensate pump, listed in the quote.

LogisVert grant

This system has an indicative LogisVert amount of $5,340, calculated according to the LogisVert rule ($120 per 1,000 BTU/h of certified heating at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The references are AHRI 216772301 and ENERGY STAR ID 3995741.

Why choose AirGreen

  • Salaried refrigeration technicians for the connection, the vacuum and the start-up.
  • Civil liability insurance of $5,000,000.
  • Warranty registration done by our team.
  • After-sales service that knows your installation.

Request your free estimate: we assess the heating and cooling needs of your two zones on site and tell you honestly whether this model is the right one.

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 44,500 BTU/h at −8 °C, 37,800 at −15 °C and 28,400 at −30 °C.

How many heads can I connect?

Up to 5 on this outdoor unit. This product is configured for 2 heads.

How much is the LogisVert grant?

$5,340. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3995741.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 28,400 BTU/h with a COP of 1.5.

Is it noisy?

Indoors, the reference head goes down to 26 dB(A). Outdoors, 69 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $5,340Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.