KINGHOME Ultra Heat R32 4-Zone Heat Pump | 36,000 BTU | Montréal, Laval, South Shore, North Shore

In stock
SKU: KM36X6O-9999
36,000BTU/h · 4 heads
−30 °Cheats down to
$4,320LogisVert, indicative
ENERGY STAR® cold climateWi-Fi includedR-32Up to 4 heads
Talk to a technician · 514 316-2973
Outdoor unit KM36X6OPossible indoor models KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDIAHRI 215708444· ENERGY STAR 3798994
In short

The Kinghome Ultra Heat 4 zones 36 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 36,000 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $4,320 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

4 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 215708444
36,000BTU/h at −8 °C
−30 °Cstill heating
4heads
2.3COP at −8 °C
$4,320LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KM36X6O

Outdoor unit

One compressor for the whole house. It supplies up to 4 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
2
24,000BTU
23
30,000BTU
234
36,000BTU
23Here
42,000BTU
2345
48,000BTU
2345
60,000BTU
23456

Kinghome Ultra Heat 4 zones 36 000 · 4 zones

36,000 BTU/h
at −8 °C
$4,320
LogisVert

Up to 4 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 100 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.0
Scale 1 – 30
HSPF2 · seasonal heating10.0
Scale 1 – 15
EER2 · cooling in peak heat12.0
Scale 1 – 20
COP at −15 °C2.1
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

36,000 BTU/h÷ 1,000 ×$120=$4,320

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215708444). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone4 wall units
On the wall1 outdoor unit4 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$4,320 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

32.52 in
KM36X6ODepth 16.81 in
40.16 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
45 A max. breaker
MCA 30 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Head 4
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 30 A, 45 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

26
41
63
20 dB(A)3040506070
26 Reference head, lowest speed41 Reference head, highest speed63 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)36,000 BTUSheet
SEER2 (seasonal cooling efficiency)21.0AHRI
EER2 (instant cooling efficiency)12.0AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
Heating
Capacity at −8 °C36,000 BTU/h · COP 2.3Sheet
Capacity at −15 °C36,000 BTU/h · COP 2.1Sheet
Capacity at −30 °C (max.)26,200 BTU/h · COP 1.51Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product4 Zones (Quad Zone)Sheet
Maximum zones4 Zones (Quad Zone)Sheet
Possible indoor modelsKW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDISheet
Indoor dimensions (W × D × H)32.87 x 7.87 x 10.83 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)353 CFMSheet
Indoor sound (reference head)26 – 41 dB(A)Sheet
Installation
Outdoor unit (W × D × H)40.16 x 16.81 x 32.52 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound63 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)30 ASheet
MOP (maximum overcurrent protection)45 ASheet
RefrigerantR-32Sheet
Wi-FiInclusSheet
Certifications and warranty
AHRI215708444AHRI
ENERGY STARYes · cold climate · ID 3798994Sheet
LogisVert grant (indicative)$4,320Sheet
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

A complete zoning plan for a single-family house

When a homeowner asks us to do the whole house without installing ductwork, the project changes scale. It's no longer about adding comfort to one difficult room, but about building a complete plan: which room gets a head, what size, and how a single outdoor unit shares its capacity among all those spaces. This 36,000 BTU, four-zone KINGHOME Ultra Heat R32 multi-zone heat pump is the tool for that kind of project: four wall-mounted heads, one of which can be a large one, connected to an outdoor unit that keeps its full nominal capacity down to -15 °C.

We install it in single-family houses in Laval, on the North Shore and on the South Shore that combine an open area, closed bedrooms and a finished basement, and in large houses in Montréal where the owner wants to replace both the baseboards and the window air conditioners.

Building the capacity budget

The KM36X6O outdoor unit accepts the CHARMO multi-zone wall-mounted heads KW09XQ19CDI (9,000 BTU), KW12XQ19CDI (12,000 BTU), KW18XQ19CDI (18,000 BTU) and KW24XQ19CDI (24,000 BTU). With four zones, the choice of each head comes from an on-site assessment of heating needs, room by room, not from a general rule. A common example:

  1. Open area on the main floor: an 18,000 BTU head.
  2. Main bedroom: a 12,000 BTU head.
  3. Second bedroom: a 9,000 BTU head.
  4. Finished basement: a 9,000 BTU head.

The total, 48,000 BTU, is higher than the outdoor unit's nominal capacity of 36,000 BTU. That's how a well-designed multi-zone system works: the four zones never all call for their maximum at the same time. At night, the open area and the basement run at low speed while the bedrooms are active; during the day, it's the reverse. The variable-speed compressor and the electronic expansion valve adjust the refrigerant flow to each head's actual demand.

Four zones is this unit's maximum

The KM36X6O can serve four zones at most. In this version, every connection is used: there won't be a fifth head added later on the same unit. So the plan has to be right from the start. During our visit, we go over every room with you, including the ones that won't get a head and how they'll be served, through an open door to a neighbouring zone or by the baseboard that stays in place.

Cold-weather performance that lets you heat the whole house

For a heat pump that serves an entire house, the key number is the capacity delivered in the dead of winter. According to the values listed on NEEP (AHRI No. 215708444) for this combination with wall-mounted heads:

  • At -8.3 °C: 36,000 BTU/h, with a COP of 2.3.
  • At -15 °C: 36,000 BTU/h, with a COP of 2.1, or 100% of the nominal capacity.
  • At -30 °C: 26,200 BTU/h, with a COP of 1.51, at the heating operating limit.

A COP of 2.1 at -15 °C means the house gets a little more than twice the heat for every kilowatt-hour used, compared with baseboards. Over a full winter, that's where most of the savings come from. The baseboards stay in place as backup, room by room, for the coldest hours. The unit carries the ENERGY STAR cold climate designation and is rated at 21 SEER2, 10 HSPF2 and 12 EER2.

A whole house controlled from your phone

Wi-Fi is included. All four zones show up in the KINGHOME PLUS app: you can schedule each one according to how it's used, shut off the basement when no one's down there and get the house ready before you come back from a trip. Each head keeps its own remote, and voice control works with Google Assistant and Amazon Alexa. Automatic vertical and horizontal louvres, 3D airflow, humidity control, self-cleaning and R-32 refrigerant leak detection come on every head.

What we check before the installation

A four-zone system on a 36,000 BTU unit is a primary heating project. Here's what we confirm during an assessment in Montréal, Laval, Longueuil, on the North Shore or the South Shore.

The electrical supply

The unit requires 220 V, an MCA of 30 A and an MOP of 45 A. All four heads are powered by the outdoor unit. We review the electrical service and the panel, taking into account the baseboards, the water heater and the appliances already connected. One circuit for four zones is still much simpler than four separate units, but that circuit has to be planned properly.

Where the outdoor unit goes

The unit measures 40.16 x 16.81 x 32.52 inches and its sound level is rated at 63 dB(A). For a unit that runs much of the winter, we choose a wall away from the bedrooms and from the neighbour's property line, and a spot where the four sets of lines come together without crossing the whole exterior wall. Wall bracket anchored into the structure, above the snow, out of the way of snow falling off the roof.

Four piping circuits

Each head is connected by its own pair of 1/4 and 3/8 inch lines. We label each line at the outdoor unit, group the routes through the basement or in a shared line cover, insulate each line along its entire length, and do the vacuum and leak test on all four circuits. At start-up, we test each zone separately to confirm that each connection serves the right room.

Four drains

Each head has its own drain, with a continuous slope to the outside. For the basement head and for any head on an interior wall, we install a condensate pump connected to a standpipe.

Certification and LogisVert assistance

Reference numbers: AHRI 215708444 and ENERGY STAR ID 3798994. The indicative LogisVert amount for this combination is $4,320, calculated using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted.

Why go with AirGreen

  • Salaried refrigeration technicians who draw up the zoning plan before quoting a price.
  • Civil liability insurance of $5,000,000.
  • Warranty registration done by our team.
  • After-sales service that keeps your four-zone configuration on file.

Ask for your free estimate: we draw up the zoning plan for your house, check your electrical service and give you a complete quote.

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 36,000 BTU/h at −8 °C, 36,000 at −15 °C and 26,200 at −30 °C.

How many heads can I connect?

Up to 4 on this outdoor unit. This product is configured for 4 heads.

How much is the LogisVert grant?

$4,320. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3798994.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 26,200 BTU/h with a COP of 1.51.

Is it noisy?

Indoors, the reference head goes down to 26 dB(A). Outdoors, 63 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $4,320Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.