KINGHOME Ultra Heat R32 6-Zone Heat Pump | 60,000 BTU | Montréal, Laval, South Shore, North Shore
The Kinghome Ultra Heat 6 zones 60 000 multi-zone heat pump heats and cools 6 rooms with a single outdoor unit. it delivers 41,000 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $2,050 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
6 rooms, one outdoor unit.
Figures come from the manufacturer’s data and the AHRI certification.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 6 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. The combination is chosen in the “Zones” menu.
Control
Each zone is set separately, also from your phone.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 60 % of its rated capacity.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
A grant you can calculate, not guess.
The capacity at −8 °C. $50 per 1,000 BTU/h is the rate for ENERGY STAR heat pumps (guide v1.10).
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
The outdoor unit, dimensioned
One circuit for the whole house
Published sound levels, on one scale.
We use the outdoor figure to choose where the unit goes.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
Six rooms, six heads: choosing the right format for each room
With six zones, this 60,000 BTU multi-zone heat pump reaches the maximum configuration of the KM60X6O outdoor unit, the only one in the Ultra Heat range that accepts six indoor heads. It's designed for large homes in Montréal, Laval, Longueuil, the North Shore and the South Shore: a two-storey house with four or five bedrooms and a finished basement, a home that has been expanded over the years, a household where everyone wants their own set point.
With this many rooms, capacity is no longer the only question. The format of each head matters just as much, because a wall-mounted head isn't always the best answer: an attic bedroom, a basement with a drop ceiling or a row of small bedrooms often calls for something else.
Six head formats, six types of rooms
The base configuration uses the CHARMO wall-mounted heads KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDI, KW30XQ21CDI and KW36XQ21CDI, from 9,000 to 36,000 BTU. KINGHOME also offers other multi-zone indoor heads that are compatible with this outdoor unit, according to the manufacturer's compatibility table. Here's where we install each one:
- Wall-mounted head: living room, bedrooms, office. It's the simplest format to install and maintain, mounted high on a clear wall.
- 8-way ceiling cassette: finished basement with a drop ceiling, large family room. Recessed in the centre of the ceiling, it blows air in every direction and takes up no wall space.
- 1-way ceiling cassette: hallway, mezzanine, narrow room where airflow in a single direction is enough, with a slim housing in a drywall ceiling.
- Floor console: under a window, on a low wall, in an attic bedroom under the roof where the wall offers no room up high. It heats at floor level, where you feel the winter.
- Floor-ceiling unit: large room without a drop ceiling, garage converted into a family room, four-season sunroom. It hangs under the ceiling or sits at the bottom of a wall.
- High-pressure ducted unit: short ducts hidden in a ceiling or the attic. A single zone then serves several small rooms, for example two children's bedrooms and a playroom, with no visible unit at all.
The 30,000 and 36,000 BTU heads, wall-mounted or ducted, connect only to this outdoor unit. No head works on its own: the outdoor unit powers and controls all six.
A typical six-zone layout
In a two-storey house with a finished basement, the combination we suggest most often is the following:
- living and dining room: 12,000 BTU wall-mounted head;
- finished basement: 12,000 BTU 8-way cassette in the drop ceiling;
- primary bedroom: 9,000 BTU wall-mounted head;
- attic bedroom: 9,000 BTU console under the window;
- home office: 9,000 BTU wall-mounted head;
- guest or teenager's bedroom: 9,000 BTU wall-mounted head.
The total matches the outdoor unit's 60,000 BTU. The on-site assessment of each room's heating needs fine-tunes each capacity; the manufacturer's selection table then sets the allowed combinations. With six small zones, one trap comes up often: choosing heads that are too big "just to be safe." An oversized head in a bedroom keeps starting and stopping and leaves the air humid in summer.
What changes with a head other than wall-mounted
This system's published values, under AHRI 218389037, were established with wall-mounted heads. A combination that includes a ducted unit, or that mixes several formats, falls under a different certification, and sometimes a different grant amount. We check the certification that applies to your exact combination before giving you an amount. Each format also has its own requirements: the cassette needs space above the ceiling and anchoring in the structure, the console a clear low wall, the ducted unit a duct route and an access hatch. All six heads always run in the same mode, heating or cooling.
Winter with six zones
This unit is ENERGY STAR certified, but it does not carry the ENERGY STAR cold climate designation, unlike the lower-capacity units in the series, even though some sales materials attribute it to the whole range. The values listed on NEEP, with wall-mounted heads (AHRI No. 218389037):
- At -8.3 °C: 41,000 BTU/h, COP of 2.58.
- At -15 °C: 36,400 BTU/h, COP of 1.9.
- At -30 °C: 20,000 BTU/h, COP of 1.25, the heating operating limit.
These capacities are shared among the six rooms calling for heat at the same time. In extreme cold, the existing heating, baseboards or furnace, should therefore stay in place; with a furnace, the range's dual-energy control automatically switches to backup when the heat pump can no longer keep up. The most exposed rooms, under the roof or above the garage, are where the backup kicks in first.
Efficiency and controls
The system has a SEER2 of 21, an EER2 of 11.65 and an HSPF2 of 10, with R-32 refrigerant, a twin rotary compressor and an electronic expansion valve. The wall-mounted heads have Wi-Fi included and can be controlled from the KINGHOME PLUS app or by voice with Google Assistant and Amazon Alexa; depending on the model, the other formats use a wired controller.
What we check before installation
The room-by-room visit
We measure each room, its windows and its exposure, then check the planned location for each head: space above the ceiling for a cassette, a clear low wall for a console, a duct route for a ducted unit. This is the step where the format of each zone is confirmed.
Power supply
The unit requires a 220 V supply, an MCA of 38 A and an MOP of 40 A, on a single circuit for all six zones. The heads are powered through the interconnect cable. Six independent units would need six circuits and six spaces in the panel; here, a single double-pole breaker is enough. We still do the electrical service load calculation, especially in a large house that already has an EV charger or a pool heat pump.
Outdoor unit location
The unit measures 35.43 x 13.39 x 49.61 inches, a vertical format, and produces 60 dB(A). We set it on a raised pad or a stand designed for its weight, above snow level, away from bedroom windows and snow sliding off the roof, with clearance for defrost water.
Six pairs of lines
Each head has its own pair of lines, 1/4 and 1/2 inch depending on the port; the higher-capacity heads go on the larger-diameter ports. With six circuits, the route is planned in advance: attic for the upper floor, basement joists for the ground floor, line covers only where there's no other way through. Each circuit is insulated, pressure-tested and vacuumed separately.
Six drains
The wall-mounted heads drain by gravity, with a steady slope toward the outside. The cassettes and the ducted unit have a built-in condensate pump; we confirm its discharge point and test the drainage at start-up. For any other head on an interior wall, a pump is included in the quote.
LogisVert grant
This system has an indicative LogisVert amount of $2,050, calculated according to the LogisVert rule ($50 per 1,000 BTU/h of certified heating at -8.3 °C, the rate for a unit without the cold climate designation); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The references are AHRI 218389037 and ENERGY STAR ID 4610343, established with wall-mounted heads.
Why choose AirGreen
- Salaried refrigeration technicians who install every head format in the range.
- Civil liability insurance of $5,000,000.
- Warranty registration done for you.
- After-sales service that knows your installation, zone by zone.
Request your free estimate: we visit your six rooms, choose the format of each head with you and check the certification for your combination.
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 41,000 BTU/h at −8 °C, 36,400 at −15 °C and 20,000 at −30 °C.
How many heads can I connect?
Up to 6 on this outdoor unit. This product is configured for 6 heads.
How much is the LogisVert grant?
$2,050. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, ID 4610343.
Down to what temperature does it heat?
Down to −30 °C. At −30 °C, it still delivers 20,000 BTU/h with a COP of 1.25.
Is it noisy?
Indoors, the reference head goes down to 26 dB(A). Outdoors, 60 dB(A): we place the unit away from bedroom windows.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
What does the warranty cover?
Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.
A multi-zone system is planned room by room. At your home.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.