KINGHOME Ultra Heat R32 6-Zone Heat Pump | 60,000 BTU | Montréal, Laval, South Shore, North Shore

In stock
SKU: KM60X6O-999999
60,000BTU/h · 6 heads
−30 °Cheats down to
$2,050LogisVert, indicative
ENERGY STAR®Wi-Fi includedR-32Up to 6 heads
Talk to a technician · 514 316-2973
Outdoor unit KM60X6OPossible indoor models KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDI, KW30XQ21CDI, KW36XQ21CDIAHRI 218389037· ENERGY STAR 4610343
In short

The Kinghome Ultra Heat 6 zones 60 000 multi-zone heat pump heats and cools 6 rooms with a single outdoor unit. it delivers 41,000 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $2,050 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

6 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 218389037
41,000BTU/h at −8 °C
−30 °Cstill heating
6heads
2.58COP at −8 °C
$2,050LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KM60X6O

Outdoor unit

One compressor for the whole house. It supplies up to 6 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
2
24,000BTU
23
30,000BTU
234
36,000BTU
234
42,000BTU
2345
48,000BTU
2345
60,000BTU
2345Here

Kinghome Ultra Heat 6 zones 60 000 · 6 zones

41,000 BTU/h
at −8 °C
$2,050
LogisVert

Up to 6 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 60 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.0
Scale 1 – 30
HSPF2 · seasonal heating10.0
Scale 1 – 15
EER2 · cooling in peak heat11.7
Scale 1 – 20
COP at −15 °C1.9
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

41,000 BTU/h÷ 1,000 ×$50=$2,050

The capacity at −8 °C. $50 per 1,000 BTU/h is the rate for ENERGY STAR heat pumps (guide v1.10).

Set for this system (AHRI 218389037). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone6 wall units
On the wall1 outdoor unit6 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$2,050 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

49.61 in
KM60X6ODepth 13.39 in
35.43 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
40 A max. breaker
MCA 38 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Head 4
Head 5
Head 6
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 1/2 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 38 A, 40 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

26
41
60
20 dB(A)3040506070
26 Reference head, lowest speed41 Reference head, highest speed60 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)60,000 BTUSheet
SEER2 (seasonal cooling efficiency)21.0AHRI
EER2 (instant cooling efficiency)11.7AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
Heating
Capacity at −8 °C41,000 BTU/h · COP 2.58Sheet
Capacity at −15 °C36,400 BTU/h · COP 1.9Sheet
Capacity at −30 °C (max.)20,000 BTU/h · COP 1.25Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product6 ZonesSheet
Maximum zones6 ZonesSheet
Possible indoor modelsKW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDI, KW30XQ21CDI, KW36XQ21CDISheet
Indoor dimensions (W × D × H)32.87 x 7.87 x 10.83 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)353 CFMSheet
Indoor sound (reference head)26 – 41 dB(A)Sheet
Installation
Outdoor unit (W × D × H)35.43 x 13.39 x 49.61 inSheet
Line sizes1/4 - 1/2 inSheet
Outdoor sound60 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)38 ASheet
MOP (maximum overcurrent protection)40 ASheet
RefrigerantR-32Sheet
Wi-FiInclusSheet
Certifications and warranty
AHRI218389037AHRI
ENERGY STARYes · ID 4610343Sheet
LogisVert grant (indicative)$2,050Sheet
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

Six rooms, six heads: choosing the right format for each room

With six zones, this 60,000 BTU multi-zone heat pump reaches the maximum configuration of the KM60X6O outdoor unit, the only one in the Ultra Heat range that accepts six indoor heads. It's designed for large homes in Montréal, Laval, Longueuil, the North Shore and the South Shore: a two-storey house with four or five bedrooms and a finished basement, a home that has been expanded over the years, a household where everyone wants their own set point.

With this many rooms, capacity is no longer the only question. The format of each head matters just as much, because a wall-mounted head isn't always the best answer: an attic bedroom, a basement with a drop ceiling or a row of small bedrooms often calls for something else.

Six head formats, six types of rooms

The base configuration uses the CHARMO wall-mounted heads KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDI, KW24XQ19CDI, KW30XQ21CDI and KW36XQ21CDI, from 9,000 to 36,000 BTU. KINGHOME also offers other multi-zone indoor heads that are compatible with this outdoor unit, according to the manufacturer's compatibility table. Here's where we install each one:

  • Wall-mounted head: living room, bedrooms, office. It's the simplest format to install and maintain, mounted high on a clear wall.
  • 8-way ceiling cassette: finished basement with a drop ceiling, large family room. Recessed in the centre of the ceiling, it blows air in every direction and takes up no wall space.
  • 1-way ceiling cassette: hallway, mezzanine, narrow room where airflow in a single direction is enough, with a slim housing in a drywall ceiling.
  • Floor console: under a window, on a low wall, in an attic bedroom under the roof where the wall offers no room up high. It heats at floor level, where you feel the winter.
  • Floor-ceiling unit: large room without a drop ceiling, garage converted into a family room, four-season sunroom. It hangs under the ceiling or sits at the bottom of a wall.
  • High-pressure ducted unit: short ducts hidden in a ceiling or the attic. A single zone then serves several small rooms, for example two children's bedrooms and a playroom, with no visible unit at all.

The 30,000 and 36,000 BTU heads, wall-mounted or ducted, connect only to this outdoor unit. No head works on its own: the outdoor unit powers and controls all six.

A typical six-zone layout

In a two-storey house with a finished basement, the combination we suggest most often is the following:

  • living and dining room: 12,000 BTU wall-mounted head;
  • finished basement: 12,000 BTU 8-way cassette in the drop ceiling;
  • primary bedroom: 9,000 BTU wall-mounted head;
  • attic bedroom: 9,000 BTU console under the window;
  • home office: 9,000 BTU wall-mounted head;
  • guest or teenager's bedroom: 9,000 BTU wall-mounted head.

The total matches the outdoor unit's 60,000 BTU. The on-site assessment of each room's heating needs fine-tunes each capacity; the manufacturer's selection table then sets the allowed combinations. With six small zones, one trap comes up often: choosing heads that are too big "just to be safe." An oversized head in a bedroom keeps starting and stopping and leaves the air humid in summer.

What changes with a head other than wall-mounted

This system's published values, under AHRI 218389037, were established with wall-mounted heads. A combination that includes a ducted unit, or that mixes several formats, falls under a different certification, and sometimes a different grant amount. We check the certification that applies to your exact combination before giving you an amount. Each format also has its own requirements: the cassette needs space above the ceiling and anchoring in the structure, the console a clear low wall, the ducted unit a duct route and an access hatch. All six heads always run in the same mode, heating or cooling.

Winter with six zones

This unit is ENERGY STAR certified, but it does not carry the ENERGY STAR cold climate designation, unlike the lower-capacity units in the series, even though some sales materials attribute it to the whole range. The values listed on NEEP, with wall-mounted heads (AHRI No. 218389037):

  • At -8.3 °C: 41,000 BTU/h, COP of 2.58.
  • At -15 °C: 36,400 BTU/h, COP of 1.9.
  • At -30 °C: 20,000 BTU/h, COP of 1.25, the heating operating limit.

These capacities are shared among the six rooms calling for heat at the same time. In extreme cold, the existing heating, baseboards or furnace, should therefore stay in place; with a furnace, the range's dual-energy control automatically switches to backup when the heat pump can no longer keep up. The most exposed rooms, under the roof or above the garage, are where the backup kicks in first.

Efficiency and controls

The system has a SEER2 of 21, an EER2 of 11.65 and an HSPF2 of 10, with R-32 refrigerant, a twin rotary compressor and an electronic expansion valve. The wall-mounted heads have Wi-Fi included and can be controlled from the KINGHOME PLUS app or by voice with Google Assistant and Amazon Alexa; depending on the model, the other formats use a wired controller.

What we check before installation

The room-by-room visit

We measure each room, its windows and its exposure, then check the planned location for each head: space above the ceiling for a cassette, a clear low wall for a console, a duct route for a ducted unit. This is the step where the format of each zone is confirmed.

Power supply

The unit requires a 220 V supply, an MCA of 38 A and an MOP of 40 A, on a single circuit for all six zones. The heads are powered through the interconnect cable. Six independent units would need six circuits and six spaces in the panel; here, a single double-pole breaker is enough. We still do the electrical service load calculation, especially in a large house that already has an EV charger or a pool heat pump.

Outdoor unit location

The unit measures 35.43 x 13.39 x 49.61 inches, a vertical format, and produces 60 dB(A). We set it on a raised pad or a stand designed for its weight, above snow level, away from bedroom windows and snow sliding off the roof, with clearance for defrost water.

Six pairs of lines

Each head has its own pair of lines, 1/4 and 1/2 inch depending on the port; the higher-capacity heads go on the larger-diameter ports. With six circuits, the route is planned in advance: attic for the upper floor, basement joists for the ground floor, line covers only where there's no other way through. Each circuit is insulated, pressure-tested and vacuumed separately.

Six drains

The wall-mounted heads drain by gravity, with a steady slope toward the outside. The cassettes and the ducted unit have a built-in condensate pump; we confirm its discharge point and test the drainage at start-up. For any other head on an interior wall, a pump is included in the quote.

LogisVert grant

This system has an indicative LogisVert amount of $2,050, calculated according to the LogisVert rule ($50 per 1,000 BTU/h of certified heating at -8.3 °C, the rate for a unit without the cold climate designation); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The references are AHRI 218389037 and ENERGY STAR ID 4610343, established with wall-mounted heads.

Why choose AirGreen

  • Salaried refrigeration technicians who install every head format in the range.
  • Civil liability insurance of $5,000,000.
  • Warranty registration done for you.
  • After-sales service that knows your installation, zone by zone.

Request your free estimate: we visit your six rooms, choose the format of each head with you and check the certification for your combination.

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 41,000 BTU/h at −8 °C, 36,400 at −15 °C and 20,000 at −30 °C.

How many heads can I connect?

Up to 6 on this outdoor unit. This product is configured for 6 heads.

How much is the LogisVert grant?

$2,050. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, ID 4610343.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 20,000 BTU/h with a COP of 1.25.

Is it noisy?

Indoors, the reference head goes down to 26 dB(A). Outdoors, 60 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $2,050Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.