KINGHOME Ultra Heat R32 4-Zone Heat Pump | 42,000 BTU | Montréal, Laval, South Shore, North Shore
The Kinghome Ultra Heat 4 zones 42 000 multi-zone heat pump heats and cools 4 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 44,500 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $5,340 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.
4 rooms, one outdoor unit.
Figures come from the manufacturer’s data and the AHRI certification.
The parts that make a multi-zone system.
Tap a part to learn more.
Outdoor unit
One compressor for the whole house. It supplies up to 5 heads.
Base pan heater
A heater keeps the outdoor unit’s base pan free of ice below 1 °C and during defrost (NEEP).
Refrigerant lines
One pair of lines per head.
Indoor heads
One head per room, each with its own remote and temperature. The combination is chosen in the “Zones” menu.
Control
Each zone is set separately, also from your phone.
Turn rooms on and off. Watch the power being shared.
One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.
Tell us your rooms. We tell you if this size is enough.
Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.
The whole series at a glance: find the box that fits you.
Each box is a product: the outdoor unit’s size, and the number of heads.
At −15 °C, it still delivers 90 % of its rated capacity.
Tap a temperature: capacity, efficiency and the cost of one hour of heating.
At every temperature, cheaper than baseboards.
Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.
The official ratings, on the same scales as before.
SEER2, HSPF2 and EER2 come from the AHRI certification.
A grant you can calculate, not guess.
The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).
One multi-zone or several wall units? Both sides, honestly.
We compare both options on your floor plan during the estimate.
What to know before installing a multi-zone system.
Dimensions, wiring and lines, drawn. Then our six steps.
The outdoor unit, dimensioned
One circuit for the whole house
Published sound levels, on one scale.
We use the outdoor figure to choose where the unit goes.
Every number, and where it comes from.
Each line carries its source; a line with no published value is not shown.
The manufacturer’s documentation, as PDF.
Everything we have written about this system.
The two-storey cottage: two zones downstairs, two zones upstairs
In a cottage, heat rises and doesn't come back down. In winter, the main floor stays cool while the upstairs bedrooms get stuffy; in summer it's worse, because the roof bakes the upper floor all afternoon and an air conditioner on the main floor never reaches the bedrooms. This 42,000 BTU, four-zone multi-zone heat pump deals with that head-on: two wall-mounted heads on the main floor, two upstairs, each with its own set point, all connected to a single KM42X6O outdoor unit.
It's the setup we install most often in two-storey houses in the residential neighbourhoods of Laval, the North Shore and the South Shore, and also in semi-detached houses and cottages in Montréal and Longueuil that were originally heated with baseboards or where the furnace doesn't serve the upper floor well.
Splitting by floor rather than by square footage
This unit accepts the CHARMO wall-mounted heads KW09XQ19CDI (9,000 BTU), KW12XQ19CDI (12,000 BTU), KW18XQ19CDI (18,000 BTU) and KW24XQ19CDI (24,000 BTU). The most common combination for a four-zone cottage is:
- a 12,000 BTU head for the living room;
- a 12,000 BTU head for the kitchen and dining room;
- a 9,000 BTU head for the main bedroom;
- a 9,000 BTU head for the second bedroom or the office.
The total comes to exactly the outdoor unit's 42,000 BTU. The upstairs heads are deliberately smaller: in winter they benefit from the heat rising from the main floor, and in summer a properly sized head runs long enough to pull the humidity out of the bedroom instead of cooling it too fast. An oversized head in a bedroom gives you a cold, clammy room. The on-site assessment of heating and cooling needs, done room by room, confirms or adjusts this split.
Every bedroom gets its own set point
The first benefit our clients notice in a cottage is the end of the arguments over the thermostat. The bedrooms can stay cool at night while the main floor is at an evening temperature, and an empty guest room can be shut off. Wi-Fi is included: all four heads can be scheduled from the KINGHOME PLUS app, and voice control works with Google Assistant and Amazon Alexa. Just one thing to know: all four zones run in the same mode at any given time, all heating or all cooling.
Where to put the heads in a cottage
Upstairs, we install the head above the door or on the wall facing the bed, never directly above the pillow: the airflow should sweep the room without blowing on the person sleeping. On the main floor, the living room head is placed so it blows toward the stairs rather than against a solid wall; some of the warm air then rises naturally to the landing. The vertical and horizontal louvres on these heads are automatic, so the airflow direction can be adjusted without anyone touching the unit once the installation is done.
Compared with four separate wall-mounted heat pumps, this system puts only one compressor outside. For a two-storey house, that means a cleaner exterior, only one spot to clear in winter and only one unit to maintain.
Summer under the roof
It's often summer that convinces a cottage owner. The system is rated at 21 SEER2 and 13 EER2, the rating that measures efficiency in peak heat. In practical terms, two heads upstairs do what no window or portable air conditioner manages: bedrooms you can actually sleep in during July. The heads dehumidify while they cool, which matters as much as the temperature in a bedroom under the eaves.
Winter: what the published numbers say
- At -8.3 °C: 44,500 BTU/h, COP of 2.4.
- At -15 °C: 37,800 BTU/h, COP of 2.1, or about 90% of the nominal capacity.
- At -30 °C: 28,400 BTU/h, COP of 1.5, the heating operating limit.
These values, listed on NEEP (AHRI No. 215708445), apply to a ductless head configuration like this one, and the unit carries the ENERGY STAR cold climate designation. In a cottage, stratification works in your favour in winter: the main-floor heads do most of the work, and the upstairs ones often run at low speed. The existing heating stays in place as backup for the coldest nights. The 10 HSPF2 sums up efficiency over the whole season.
What we check before the installation
The electrical supply
The outdoor unit requires a 220 V supply, an MCA of 30 A and an MOP of 45 A. All four heads are powered from the outdoor unit through the interconnecting cable: one circuit at the panel for four rooms, versus four circuits if you installed four separate wall-mounted heat pumps. We check the electrical service and the panel during the visit.
Where the outdoor unit goes
The unit measures 40.16 x 16.81 x 32.52 inches and its sound level is 63 dB(A). We mount it on a wall bracket or a raised stand, above snow level, out of the way of snow sliding off the roof. For a cottage, we ideally pick the wall that gives the shortest route to both floors.
The lines to the upper floor
Each head has its own pair of 1/4 and 3/8 inch lines. For the upstairs heads, we run the lines up the outside wall under a line cover, or inside through a closet or a partition when the structure allows it. All four circuits are vacuumed separately and checked with nitrogen before start-up.
The drains
Upstairs, each head's drain needs a steady slope to the outside; a drain that sags inside a wall eventually overflows onto a ceiling. When a proper slope isn't possible, we install a condensate pump and we spell it out in the quote.
LogisVert assistance and certification
The indicative LogisVert amount for this system is $5,340, calculated using the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted. The references are AHRI 215708445 and ENERGY STAR ID 3798995.
Why go with AirGreen
- Salaried refrigeration technicians, not improvised subcontracting.
- Civil liability insurance of $5,000,000.
- Warranty registration done for you.
- After-sales service that knows your system.
Ask for your free estimate: we look at both floors of your house, assess the heating needs of each room on site and give you a clear quote for your four zones.
Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.
What people ask us about multi-zone systems.
Can I heat one room and cool another at the same time?
No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.
What happens when every room calls for heat?
They share the outdoor unit’s capacity: 44,500 BTU/h at −8 °C, 37,800 at −15 °C and 28,400 at −30 °C.
How many heads can I connect?
Up to 5 on this outdoor unit. This product is configured for 4 heads.
How much is the LogisVert grant?
$5,340. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.
Is it ENERGY STAR certified?
Yes, cold climate, ID 3798995.
Down to what temperature does it heat?
Down to −30 °C. At −30 °C, it still delivers 28,400 BTU/h with a COP of 1.5.
Is it noisy?
Indoors, the reference head goes down to 26 dB(A). Outdoors, 63 dB(A): we place the unit away from bedroom windows.
Why a multi-zone instead of several wall units?
One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.
What does the warranty cover?
Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.
A multi-zone system is planned room by room. At your home.
We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.