KINGHOME Ultra Heat R32 3-Zone Heat Pump | 30,000 BTU | Montréal, Laval, South Shore, North Shore

In stock
SKU: KM30X6O-999
30,000BTU/h · 3 heads
−30 °Cheats down to
$3,360LogisVert, indicative
ENERGY STAR® cold climateWi-Fi includedR-32Up to 4 heads
Talk to a technician · 514 316-2973
Outdoor unit KM30X6OPossible indoor models KW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDIAHRI 215708443· ENERGY STAR 3798993
In short

The Kinghome Ultra Heat 3 zones 30 000 multi-zone heat pump heats and cools 3 rooms with a single outdoor unit. ENERGY STAR cold-climate certified, it delivers 28,000 BTU/h at −8 °C, heats down to −30 °C and has an indicative LogisVert amount of $3,360 (only Hydro-Québec confirms the assistance granted). Installed by AirGreen in Montréal, Laval, Longueuil, the North Shore and the South Shore.

01 · The verdict in 10 seconds

3 rooms, one outdoor unit.

Figures come from the manufacturer’s data and the AHRI certification.

AHRI 215708443
28,000BTU/h at −8 °C
−30 °Cstill heating
3 → 4heads, on the same unit
2.45COP at −8 °C
$3,360LogisVert, indicative
02 · The machine

The parts that make a multi-zone system.

Tap a part to learn more.

KM30X6O

Outdoor unit

One compressor for the whole house. It supplies up to 4 heads.

03 · How it works

Turn rooms on and off. Watch the power being shared.

One outdoor unit supplies every head: when several rooms call at once, they share its capacity. Pick an outdoor temperature.

04 · My plan

Tell us your rooms. We tell you if this size is enough.

Pick the number of rooms and their size. The estimate targets a −15 °C day; it is a guide, the real calculation is done room by room at your home.

05 · The series

The whole series at a glance: find the box that fits you.

Each box is a product: the outdoor unit’s size, and the number of heads.

Outdoor2 zones3 zones4 zones5 zones6 zones
18,000BTU
2
24,000BTU
23
30,000BTU
2Here4
36,000BTU
234
42,000BTU
2345
48,000BTU
2345
60,000BTU
23456

Kinghome Ultra Heat 3 zones 30 000 · 3 zones

28,000 BTU/h
at −8 °C
$3,360
LogisVert

Up to 4 heads on this outdoor unit. Tap another box to see that size.

06 · Deep cold

At −15 °C, it still delivers 90 % of its rated capacity.

Tap a temperature: capacity, efficiency and the cost of one hour of heating.

07 · The bill

At every temperature, cheaper than baseboards.

Cost of one hour at full output, for the same heat delivered. Hydro-Québec Rate D, second tier: 11.142 ¢/kWh.

08 · Efficiency

The official ratings, on the same scales as before.

SEER2, HSPF2 and EER2 come from the AHRI certification.

SEER2 · seasonal cooling21.0
Scale 1 – 30
HSPF2 · seasonal heating10.0
Scale 1 – 15
EER2 · cooling in peak heat13.6
Scale 1 – 20
COP at −15 °C2.07
Scale 0 – 4
09 · LogisVert grant

A grant you can calculate, not guess.

28,000 BTU/h÷ 1,000 ×$120=$3,360

The capacity at −8 °C. $120 per 1,000 BTU/h is the rate for ENERGY STAR cold-climate heat pumps (guide v1.10).

Set for this system (AHRI 215708443). Another head combination (ducted, console) can change the AHRI number, and so the amount.
Cap: the grant never exceeds 100 % of the purchase and installation cost before taxes.
9 months after installation to apply; +5 % when two measures are in the same request.
All about LogisVert, with the simulator
10 · Multi-zone or wall units

One multi-zone or several wall units? Both sides, honestly.

This multi-zone3 wall units
On the wall1 outdoor unit3 outdoor units
Electrical1 dedicated circuitOne circuit per unit
CapacityShared between roomsReserved for each room
If the outdoor unit stopsEvery zone stopsOnly one room
ModesSame mode everywhereEach room chooses
LogisVert$3,360 for the systemDepends on each model

We compare both options on your floor plan during the estimate.

11 · Installation

What to know before installing a multi-zone system.

Dimensions, wiring and lines, drawn. Then our six steps.

The outdoor unit, dimensioned

32.52 in
KM30X6ODepth 16.81 in
40.16 in
Dimensions: product sheet (W × D × H).

One circuit for the whole house

Electrical panel
Load calculation before the quote
35 A max. breaker
MCA 23 A · 220 V
Outdoor unit
Head 1
Head 2
Head 3
Our RBQ licence covers electrical work (subclass 16).
01Room-by-room visit and surveyWe measure each zone and note insulation and windows. The on-site estimate is free.
02Heads and line layoutOne pair of lines per head.
03Outdoor unit baseAbove the snow line, away from the neighbours’ bedroom windows.
04Exposed, finished linesLines 1/4 - 3/8 in under line covers, no work inside the walls.
05Dedicated circuit220 V, MCA 23 A, 35 A protection. The panel load calculation is done before the quote.
06Commissioning, zone by zoneEach head is tested and the controls set up. Then the LogisVert application within 9 months.
12 · Sound

Published sound levels, on one scale.

We use the outdoor figure to choose where the unit goes.

26
41
58
20 dB(A)3040506070
26 Reference head, lowest speed41 Reference head, highest speed58 Outdoor unit
Values in dB(A). Indoor values are those of the sheet’s reference head; each head has its own, confirmed for the chosen model. Municipal noise by-laws vary by borough.
13 · Specifications

Every number, and where it comes from.

Each line carries its source; a line with no published value is not shown.

Performance
Cooling capacity (size)30,000 BTUSheet
SEER2 (seasonal cooling efficiency)21.0AHRI
EER2 (instant cooling efficiency)13.6AHRI
HSPF2 (seasonal heating efficiency, region IV)10.0AHRI
Heating
Capacity at −8 °C28,000 BTU/h · COP 2.45Sheet
Capacity at −15 °C27,000 BTU/h · COP 2.07Sheet
Capacity at −30 °C (max.)21,000 BTU/h · COP 1.45Sheet
Heats down to−30 °CSheet
Zones and heads
Zones on this product3 Zones (Triple Zone)Sheet
Maximum zones4 Zones (Quad Zone)Sheet
Possible indoor modelsKW09XQ19CDI, KW12XQ19CDI, KW18XQ19CDISheet
Indoor dimensions (W × D × H)32.87 x 7.87 x 10.83 inSheet
Vertical louversAutoSheet
Horizontal louversAutoSheet
Airflow (reference head)353 CFMSheet
Indoor sound (reference head)26 – 41 dB(A)Sheet
Installation
Outdoor unit (W × D × H)40.16 x 16.81 x 32.52 inSheet
Line sizes1/4 - 3/8 inSheet
Outdoor sound58 dB(A)Sheet
Electrical
Voltage220 VSheet
MCA (minimum circuit ampacity)23 ASheet
MOP (maximum overcurrent protection)35 ASheet
RefrigerantR-32Sheet
Wi-FiInclusSheet
Certifications and warranty
AHRI215708443AHRI
ENERGY STARYes · cold climate · ID 3798993Sheet
LogisVert grant (indicative)$3,360Sheet
Warranty (compressor · parts · labour)12 yrs · 12 yrs · 6 yrsSheet
AirGreen extended warrantyPossibleSheet
14 · Official brochures

The manufacturer’s documentation, as PDF.

15 · Description

Everything we have written about this system.

Three zones for a two-storey family home

In a family cottage, everyone lives in the house on their own schedule. The ground-floor living area is in use from morning to night, the primary bedroom mostly at night, and the kids' room or playroom depending on the school schedule. With a single thermostat for the whole house, someone is always too hot or too cold. This 30,000 BTU three-zone KINGHOME Ultra Heat R32 multi-zone heat pump gives each of these spaces its own wall-mounted head and its own set point, from a single outdoor unit.

It's the setup we recommend most often for two-storey houses in Laval, on the North Shore and on the South Shore, built with electric baseboard heating and no air conditioning ducts. In Montréal, it also suits two-level townhouses and the upper floors of duplexes converted into single-family homes.

A typical layout on two levels

The KM30X6O outdoor unit accepts three sizes of CHARMO multi-zone wall-mounted heads: KW09XQ19CDI (9,000 BTU), KW12XQ19CDI (12,000 BTU) and KW18XQ19CDI (18,000 BTU). Here is the layout we suggest most often:

  1. Ground floor: an 18,000 BTU head in the kitchen and living area, positioned to blow toward the staircase.
  2. Primary bedroom: a 12,000 BTU head, above the door or on the wall opposite the bed.
  3. Second bedroom or playroom: a 9,000 BTU head.

The heads add up to 39,000 BTU, more than the 30,000 BTU nominal capacity. That's a common and sound choice in multi-zone: the primary bedroom needs little during the day, and the living area needs little at night. The variable-speed compressor and the electronic expansion valve send refrigerant to the heads that need it. What you want to avoid is the opposite excess: an 18,000 BTU head in a small bedroom would keep starting and stopping, leaving the room cold and damp in summer.

Three zones rather than two or four

The same outdoor unit comes in two-zone and four-zone versions. Two zones often leave an upstairs bedroom without a head, which means keeping doors open or relying on the baseboard. Four zones make sense when the house has several closed bedrooms of similar size. In between, three zones cover the rooms where the family actually spends its time, with a simpler installation, fewer lines on the façade and better control over cost.

Winter on two floors

Heat produced on the ground floor naturally rises up the staircase. A good three-zone installation takes advantage of this: the living-area head does most of the work in winter, and the bedroom heads top things up without straining. In summer, it's the reverse: the upstairs heads, where heat builds up, work harder.

The capacities listed on NEEP for this combination with wall-mounted heads (AHRI No. 215708443):

  • 28,000 BTU/h at -8.3 °C, COP of 2.45.
  • 27,000 BTU/h at -15 °C, COP of 2.07, or 90% of nominal capacity.
  • 21,000 BTU/h at -30 °C, COP of 1.45, the heating operating limit.

For a reasonably well-insulated, medium-sized cottage, this level covers most of the winter's heating needs. The baseboards stay in place and only come on if a room drops below its set point during extreme cold. The unit carries the ENERGY STAR cold climate designation.

Efficiency through the seasons

The system is certified at 21 SEER2, 10 HSPF2 and 13.6 EER2, the best EER2 in the multi-zone series. For a family, that means cooling the upstairs stays affordable even in the middle of a heat wave. Each head offers vertical and horizontal auto louvres, 3D airflow, humidity control and self-cleaning.

Simple controls for the whole family

Wi-Fi is included. All three zones show up in the KINGHOME PLUS app: you can program the kids' room for bedtime, turn down the living area during office hours and check on the house remotely. Each head also keeps its own remote, and voice control works with Google Assistant and Amazon Alexa.

What we check before installation

A two-storey house with three heads calls for more careful planning than a two-zone system. Here are the points we validate during an assessment in Montréal, Laval, Longueuil, on the North Shore or the South Shore.

Electrical supply

The unit requires a 220 V supply, an MCA of 23 A and an MOP of 35 A. All three heads are powered by the outdoor unit, on that one circuit. Three independent wall-mounted heat pumps would need three separate circuits: in a baseboard-heated house, where the panel is often loaded, saving that space weighs in the decision.

Outdoor unit location

The unit measures 40.16 x 16.81 x 32.52 inches, with a sound level of 58 dB(A). We mount it on a wall bracket anchored into the structure, above the snow, ideally on the wall closest to where the lines go up to the second floor. We avoid spots under the deck or under snow sliding off the roof, and right next to a bedroom window.

Three piping runs

Each head gets its own pair of 1/4 and 3/8 inch lines. The two upstairs lines go up together in a single line cover along the façade, or through stacked closets when the structure allows. The ground-floor line stays short. We limit elbows, insulate each line along its full length, then vacuum and leak-test each circuit.

Drains

The upstairs heads are the trickiest: their drain has to run down with a continuous slope without crossing a finished room. When that's not possible, we install a discreet condensate pump. The ground-floor head usually drains straight outside.

Certification and LogisVert assistance

Reference numbers: AHRI 215708443 and ENERGY STAR ID 3798993. This combination has an indicative LogisVert amount of $3,360, calculated according to the LogisVert rule ($120 per 1,000 BTU/h of certified heating capacity at -8.3 °C); eligibility is confirmed on the installation date. Only Hydro-Québec confirms the assistance granted.

Why go with AirGreen

  • Salaried refrigeration technicians who plan every line run before drilling.
  • Civil liability insurance of $5,000,000.
  • Warranty registration done by us at commissioning.
  • After-sales service that knows how your three zones are laid out.

Request your free estimate: we visit both floors, suggest the right head size for each room and give you a quote with no surprises.

Warranty: 12 years on the compressor, 12 years on parts and 6 years on labour, directly from the distributor, on registered models.

16 · Questions

What people ask us about multi-zone systems.

Can I heat one room and cool another at the same time?

No. On a multi-zone system like this one, every head works in the same mode, heating or cooling. Each room still keeps its own set temperature.

What happens when every room calls for heat?

They share the outdoor unit’s capacity: 28,000 BTU/h at −8 °C, 27,000 at −15 °C and 21,000 at −30 °C.

How many heads can I connect?

Up to 4 on this outdoor unit. This product is configured for 3 heads.

How much is the LogisVert grant?

$3,360. The grant never exceeds 100 % of the cost before taxes; apply within 9 months of installation.

Is it ENERGY STAR certified?

Yes, cold climate, ID 3798993.

Down to what temperature does it heat?

Down to −30 °C. At −30 °C, it still delivers 21,000 BTU/h with a COP of 1.45.

Is it noisy?

Indoors, the reference head goes down to 26 dB(A). Outdoors, 58 dB(A): we place the unit away from bedroom windows.

Why a multi-zone instead of several wall units?

One outdoor unit on the wall and one circuit. In return, the rooms share the capacity, and if the outdoor unit stops, every zone stops.

What does the warranty cover?

Our sheet lists 12 years on the compressor and 12 years on parts. AirGreen extended warranty: possible.

AirGreen

A multi-zone system is planned room by room. At your home.

We measure every room, draw the line route and choose the right head for each zone. The on-site estimate is free and the quote arrives within 24 h.

RBQ 5645-9605-01Ventilation 15.8, refrigeration 15.10, electrical 16
We handle the circuitOur licence covers the electrical work
LogisVert : $3,360Indicative amount
Beware of scamsHydro-Québec does no phone or door-to-door solicitation for LogisVert
SourcesCosts: Hydro-Québec Rate D, 11.142 ¢/kWh (second tier, since 1 April 2026). Amounts shown are estimates; only the responsible bodies confirm the grant awarded.