Mon–Thu 8 a.m.–6 p.m., Fri 8 a.m.–4 p.m.
Honeywell Home · made by Resideo · checked October 13, 2026
Honeywell Home: the right thermostat starts behind the wall plate
Baseboards at 120 or 240 V, floor heating, a furnace or central heat pump on 24 V, whole-home humidity: with Honeywell Home, every control depends on what reaches the wall. Tell us what is behind yours; the numbers come from the manufacturer’s guides.
What is behind your thermostat?
Baseboards and convectors: line-voltage electronic thermostats
- Aube TH114 and TH115 series, TH106, TH401, TH450, LineVoltPRO
- Up to 16.7 A, or 4,000 W at 240 V, on the single-pole S models
- Resistive loads only, installed by an electrician (Honeywell)
- 16.7 A
- Baseboards: single-pole TH114 and TH115 at 240 V
- 4 + 2
- Heating + cooling stages, ElitePRO on a heat pump
- 22 gal
- Per day: HM750 steam humidifier at 240 V
- 5 years
- Manufacturer warranty: 24 V thermostats and humidifiers
01 Baseboards and heated floors
Line voltage: amperage comes first
These thermostats switch the baseboard or heating cable directly. The circuit load must stay under the limit printed in Honeywell’s guide, with resistive loads only and a certified electrician.
Work out the circuit load
Circuit voltage What the thermostat controlsAdd up the watts printed on every baseboard wired to the same thermostat. Amps = watts ÷ volts is only for picking the model; the circuit itself is the electrician’s job.
S or D? In the Aube series, S = single pole (16.7 A) and D = double pole (15 A, breaks both 240 V wires). The 024T versions drive a 24 V relay, not the baseboard: they go with a relay, on quotation. The CT230 module adds a 15 A floor circuit; Honeywell pairs it with the 12 VDC version of the TH114/TH115.
AirGreen × Honeywell Home
Honeywell Home’s controls, a local install.
Honeywell Home, made by Resideo, designs the thermostats, the zoning and the humidity equipment. AirGreen picks with you the model that matches what is behind your wall plate. Each does what it does best.
What Honeywell Home brings
- One control per heating systemBaseboards at 120 or 240 V, radiant floors, 24 V, hot water: four thermostat families, according to Resideo’s guides.
- 4 heat + 2 cool stagesElitePRO on a heat pump, dual fuel and humidity, according to Resideo’s selection guide 50-1376.
- 22 gal/day at 240 VThe HM750 steam humidifier; the evaporative TrueEASE units give 12 to 18 gal/day, according to Resideo.
- 5-year manufacturer warranty24 V thermostats, humidifiers and DR dehumidifiers, on the terms of Resideo’s documents.
What AirGreen brings
- Sold and installed by AirGreen24 V thermostats, zoning, humidifiers and dehumidifiers, in Montreal, Laval, Longueuil, the South Shore and the North Shore.
- Free estimateA photo of the current thermostat and the wires behind it: that is where it starts.
- Programs checkedENERGY STAR and Énergir’s PE-204 list, model by model, read on 13 October 2026.
- RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16.
The result: the right Honeywell Home for what is behind your wall plate, chosen with you.
02 Furnace, heat pump, air conditioner
Low voltage: what your wires allow
On 24 V, the thermostat drives the equipment through thin coloured wires. Stage count, the C-wire and the heat pump decide the model. Capacities come from Resideo selection guide 50-1376 (September 2025).
Find the 24 V thermostat
Your systemOn a heat pump, count the compressor and the electric backup: 1 compressor + 1 backup = 2.
Cooling stages Is there a C (common) wire at the thermostat? Remote control by app Also control humidityWhat the tool leaves out: the T10 Pro, PRO 1000, The Round and the mechanical thermostats stay in the grid below, but the tool only offers models described in Resideo’s current documents. The real wire and stage count is checked on site, on quotation.
03 Rebates and certifications
ENERGY STAR, Énergir, LogisVert: what really applies
Checked October 13, 2026 on each program’s own site. ENERGY STAR certifies smart thermostats, not humidifiers. Énergir helps customers heated with natural gas. Hydro-Québec’s LogisVert covers no thermostat, humidifier or dehumidifier.
ENERGY STAR
Certified
Yes: ENERGY STAR record 4429195, certified May 28, 2025
Énergir
Up to $100
Yes: named in Énergir’s PE-204 list (valid from April 1, 2026)
LogisVert
Not eligible
Guide v1.10 (September 15, 2026) covers no thermostat.
Énergir: up to $100 per smart thermostat named on its PE-204 list (valid from April 1, 2026), for homes heated mainly with natural gas; Énergir states that amounts and conditions may change. You apply with Énergir. ENERGY STAR is not a rebate: it is a certification.
04 TrueZONE zoning
One system, several zones: which panel?
A TrueZONE panel opens and closes duct dampers so each zone is heated or cooled to its own setpoint. Capacities come from Resideo zoning catalogue 70-0851 (February 2022).
Pick the panel
Number of zones Your systemZD and ARD dampers: 24 V, spring return, open by default on failure (Resideo catalogue).
05 Whole-home humidifiers
Bypass, fan or steam: the choice is made at the duct
Honeywell sizes its humidifiers in cubic feet (area × ceiling height), not square feet. Evaporative units are rated with 49 °C (120 °F) plenum air; steam is rated by voltage.
Volume to humidify
14,400 cu ft
Access to the return for a bypass duct A dedicated 240 V circuit is possible
Bypass
Covers your volume
Published coverage: 16,000 to 20,000 cu ft
- 12 or 17 gal/day, rated with 49 °C (120 °F) plenum air
- 6-in bypass duct between supply and return
- HE150 and HE250: automatic bypass damper
- HumidiPRO included

Fan-powered
Covers your volume
Published coverage: 24,000 cu ft
- 18 gal/day, rated with 49 °C (120 °F) plenum air
- No bypass duct, 120 V outlet, 1 A
- On the return: warm water strongly recommended by Honeywell
- HumidiPRO included

Electrode steam
Covers your volume
HM750: 24,000 cu ft at 240 V
- 11 gal/day at 120 V, 22 gal/day at 240 V (1.5 or 3 kW)
- Dedicated 15 A circuit, cold water, drain rated for 93 °C (200 °F)
- Minimum airflow: 115 CFM at 120 V, 230 at 240 V
- Cylinder replaced about once a year
With a heat pump? Honeywell publishes no heat-pump compatibility statement for these humidifiers. What it does publish: evaporative units are rated with 49 °C (120 °F) plenum air, and steam depends only on voltage and a minimum airflow. We look at your system on site before choosing.
| Model | Type | Gal/day | Published coverage | Consumable |
|---|---|---|---|---|
| HE100 | Bypass | 12 | 16,000 cu ft | HC22 pad |
| HE150 | Bypass, auto damper | 12 | 16,000 cu ft | HC22 pad |
| HE200 | Bypass | 17 | 20,000 cu ft | HC26 pad |
| HE250 | Bypass, auto damper | 17 | 20,000 cu ft | HC26 pad |
| HE300 | Fan-powered | 18 | 24,000 cu ft | HC26 pad |
| HE105 | Bypass | 12 | Not published | HC22 pad, yearly |
| HE205 | Bypass | 17 | Not published | HC26 pad |
| HM750 | Steam | 11 / 22 | 12,000 / 24,000 cu ft | HM750ACYL cylinder, ≈ 1 year |
Sources: Resideo guides 69-2413EF (TrueEASE), 69-2414EFS, 33-00229EF (HE105/HE205), 33-00289 (HM750). HM750: 11 gal/day at 120 V, 22 gal/day at 240 V. One published installation: HM750A1000 steam humidifier in Montreal (April 2024).
06 Winter humidity
The colder it is outside, the less you humidify
Honeywell’s homeowner manual (69-2414EFS, July 2020) gives a starting point by outdoor temperature, to limit condensation on windows.
07 Whole-home dehumidifiers
DR65, DR90, DR120: drying the whole house
Connected to the ducts, they pull water from the air of the whole house and send it to the drain. Figures from Resideo’s March 2023 spec sheets.

| DR65A3000 | DR90A3000 | DR120A3000 | |
|---|---|---|---|
| Pints/day at 80 °F, 60% RH | 65 | 90 | 120 |
| Pints/day at 70 °F, 60% RH | 47 | 65 | 88 |
| Published coverage | 1,800 sq ft | 2,800 sq ft | 3,500 sq ft |
| Water removed per kWh | 2.22 L | 2.9 L | 2.9 L |
| Power | 120 V · 5.2 A | 120 V · 5.3 A | 120 V · 7.3 A |
| Ducts | 8 in | 10 in + 6 in fresh air | 10 in + 6 in fresh air |
| Filter | MERV-11 | MERV-11 | MERV-11 |
Resideo spec sheets 33-00328, 33-00329 and 33-00330 (rev. 03-23). No Québec program subsidizes a dehumidifier (checked October 13, 2026).
08 Sensors, gateways, modules
RedLINK 2.0 or 3.0: each accessory goes with its thermostat
Honeywell wireless accessories do not mix across generations. Here is what each one does, per Resideo’s documents.
RedLINK 3.0
For ElitePRO S1000, S1100, S1200 and T10+ Pro
- C7189R3002 · Indoor sensor, temperature and humidity
- C7189R3010-2 · Room sensors (2), up to 20 per ElitePRO
- C7089R3013 · Wireless outdoor sensor
- EIM4010 · EIM 3.0 module (not for the S900)
RedLINK 2.0
For VisionPRO 8000 RedLINK and wireless FocusPRO
- C7189R1004 · Wireless indoor sensor
- C7089R1013 · Wireless outdoor sensor
- THM6000R7001 · Internet gateway (app)
- THM5421R1021 · EIM: up to 4 heat / 2 cool on a heat pump, 3 air-quality contacts
- THM5320R1000 · EIM for wireless FocusPRO
- THM4000R1000 · Wireless adapter for TrueZONE
- REM5000R1001 · Portable comfort control
Wired and humidity
Sensors and humidity control
- C7189U1005 · Wired indoor sensor
- C7089U1006 · Wired outdoor sensor, up to 200 ft of wire
- H6062A1000 · HumidiPRO: 20 to 60% RH in auto, ±5% RH
- TG511A1000 · Thermostat guard
09 Warranties
The manufacturer’s warranty, family by family
Resideo’s warranty, on the terms of its documents: repair or replacement at the manufacturer’s choice, proof of purchase required; removal and reinstallation costs are excluded on humidifiers and dehumidifiers.
| Family | Warranty | Source |
|---|---|---|
| Aube line-voltage thermostats (TH105PLUS, TH106, TH114, TH115, TH401, TH450) | 3 years | Owner’s guides |
| Floor heating (TH114-AF, TH115-AF, CT230) | 3 years | 33-00226EFS, 33-00221EFS, 33-00222EFS |
| LineVoltPRO TL8130, TL8230 | On quotation (3 or 5 years depending on the document) | 69-1805EF, 69-1803ES |
| Residential 24 V thermostats (FocusPRO, T6 Pro, Wi-Fi 9000, ElitePRO) | 5 years | Selection guide 50-1376 |
| TrueZONE zoning | 5 years (60 months from installation) | 70-0851 |
| SuitePRO TB6575 (fan coil) | 2 years | 62-0278 |
| TrueEASE, HE105, HE205, HM750 humidifiers | 5-year limited | 69-2414EFS, 33-00229EF, 33-00289 |
| DR65, DR90, DR120 dehumidifiers | 5-year limited | 33-00297EFS, 33-00298EFS |
| Other modules and accessories | On quotation | — |
10 Honeywell at AirGreen
The Honeywell collections, one per family
Each family also has its own page, with its filters. The brand’s full grid is right below.
11 Frequently asked questions
Honeywell thermostats and humidity: your questions
Search a word (C-wire, Énergir, steam…) to filter the answers.
Which Honeywell thermostat for electric baseboards?
A line-voltage electronic thermostat from the Aube series: TH114 (non-programmable), TH115 or TH106 (programmable), TH401, TH450 or LineVoltPRO. Single-pole S models take up to 16.7 A, double-pole D models 15 A. The calculator in section 01 sorts them by your wattage.
Can I use a baseboard thermostat on my furnace?
No. Honeywell states its line-voltage thermostats are not for central heating or inductive loads. A furnace or central heat pump needs a 24 V thermostat (section 02).
What is the C-wire?
The 24 V common wire that powers the thermostat continuously. It is required on the T6 Pro Smart, FocusPRO S200, Wi-Fi 9000 and the ElitePRO models. The FocusPRO N100 and P200 and the non-connected T6 Pro also run on batteries.
Which thermostat for a heat pump with electric backup?
You need at least 2 heat-pump heating stages: FocusPRO N100 or P200 2H/1C and 3H/2C, T6 Pro, T6 Pro Smart, VisionPRO 8000, Wi-Fi 9000 or ElitePRO (up to 4 heat / 2 cool). The T6 Pro TH6220U and TH6320U also handle dual fuel.
Are Honeywell thermostats eligible for LogisVert?
No. Hydro-Québec’s LogisVert guide (version 1.10, September 15, 2026) covers no thermostat, humidifier or dehumidifier.
Does Énergir pay toward a Honeywell thermostat?
For homes heated mainly with natural gas, Énergir offers up to $100 per smart thermostat named on its PE-204 list (valid from April 1, 2026): ElitePRO, T10 Pro, T6 Pro Wi-Fi, FocusPRO S200, Wi-Fi 9000 and VisionPRO 8000. You apply with Énergir, on its terms.
Bypass, fan or steam: what is the difference?
A bypass unit uses the pressure difference between supply and return and needs a 6-in bypass duct. The fan model (HE300) moves the air itself, with no bypass. Steam (HM750) boils water: 11 gal/day at 120 V, 22 gal/day at 240 V, on a dedicated circuit.
Does a Honeywell humidifier work with a heat pump?
Honeywell publishes no statement on this. Evaporative units are rated with 49 °C (120 °F) plenum air; steam depends on voltage and a minimum airflow. We assess your system on site before recommending a type.
What humidity should I aim for in winter?
Honeywell’s guide suggests starting at 15% at −29 °C, 20% at −23 °C, 25% at −18 °C, 30% at −12 °C and 35% at −7 °C and above, to limit condensation on windows.
What maintenance does a humidifier need?
Evaporative units use an HC22 or HC26 pad; for the HE105 and HE205, Honeywell recommends replacing it every year, more often with hard water. On the HM750 the cylinder is replaced about once a year, depending on water and use.
How many zones with TrueZONE?
2 to 3 zones with the HZ311 and HZ322, 2 zones with the HZ221 (heat pump), and 2 to 4 with the HZ432, expandable to 32 zones with TAZ-4H modules.
Who makes Honeywell Home products?
Resideo Technologies, which uses the Honeywell Home brand under licence from Honeywell International (Resideo’s 2025 annual 10-K report).
How much is a Honeywell thermostat or humidifier installed?
Price on quotation: the model, wiring, ductwork and electrical work change everything. The estimate is free.
No answer contains that word. Call us at 514 316-2973.
Sources (consulted October 13, 2026)
- Resideo, Programmable and Non-Programmable Thermostat Selection Guide 50-1376, rev. AR, September 2025.
- Aube guides: TH114 33-00622EFS-01; TH115 69-2617EFS-05 (rev. 05-22); TH106 69-2544EFS-12; TH105PLUS 69-2788EF-09; TH401 69-2550EFS-09; TH450 69-2659EF-05; TL8130 69-1805EF-07; TL8230 69-1803ES-09.
- Floor: TH114-AF 33-00226EFS-06 (rev. 07-22); TH115-AF 33-00221EFS-08 (rev. 06-22); CT230 33-00222EFS-04 (rev. 02-20).
- 24 V: T6 Pro 33-00181EFS-19; T6 Pro Smart 33-00411-04; T6 Pro Z-Wave 33-00347-04; Wi-Fi 9000 33-00341-02; VisionPRO 8000 RedLINK 68-0312-02; ElitePRO S1200 33-00706ES-01 (rev. 7/25); TH140 33-00055F-05; EIM 3.0 33-00745EFS-02.
- Resideo, Zoning Products Catalog 70-0851-18, rev. 02-22.
- Humidity: TrueEASE 69-2413EF-19 and 69-2414EFS-01 (rev. 07-20); HE105/HE205 33-00229EF-05 (rev. 07-22); HM750 33-00289-01; HumidiPRO 33-00003-02 (rev. 10-20); DR65/DR90/DR120 33-00328-04, 33-00329-03, 33-00330-03 (rev. 03-23), 33-00297EFS, 33-00298EFS.
- ENERGY STAR, “Certified Smart Thermostats” dataset (7p2p-wkbf), consulted October 13, 2026.
- Énergir, PE-204 “Smart thermostats” list, valid from April 1, 2026, and the grant page, consulted October 13, 2026.
- Hydro-Québec, LogisVert residential participation guide, version 1.10, September 15, 2026.
- Resideo Technologies, fiscal 2025 annual report on Form 10-K (Honeywell Home trademark licence).
Price on quotation · free estimate
The Honeywell Home shop
All our Honeywell products, right below.
Line-voltage and 24 V thermostats, TrueZONE zoning, humidifiers and dehumidifiers: filter, then open the product page. Price on quotation.