CONFORTO Hiboy KHE-02-G023-H3 Electric Furnace | 23 kW - 240V

In stock

Conforto’s 23 kW multiposition Hiboy electric furnace with a five-speed 1/2 HP ECM motor, for a central system with a heat pump or air conditioner up to 3.0 tons.

Model numberKHE-02-G023-H3

23 kWheating at 240 V (78,530 BTU/h)
1,275 CFMHIGH speed at 0.2 in. w.c.
5 speeds1/2 HP ECM motor
240 V · single phaseECM motorMultipositionHorizontal left not allowed
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberKHE-02-G023-H3
ManufacturerConforto
Output23 kW (78,530 BTU/h)
FormatMultiposition Hiboy
Power supply240 V, 60 Hz, 1 ph
MotorECM (Ecotech) 1/2 HP, 5 speeds
Max. cooling3.0 tons

A 23 kW ECM Hiboy, the indoor heart of your future central system

What it is, and who it is for

The Conforto KHE-02-G023-H3 is a 23 kW Hiboy electric furnace, or 78,530 BTU/h according to the manufacturer, equipped with a five-speed 1/2 HP ECM (Ecotech) motor. It heats a home with solid heating needs on its own, and it becomes the indoor unit of a complete central system as soon as a heat pump or air conditioner coil is added, up to 3.0 tons.

It is aimed at homeowners converting their central heating to a heat pump, or getting ready to, whose mechanical space calls for a particular position: utility closet, narrow mechanical room, ducts under the floor.

Why the ECM motor matters with a heat pump

A coil works well when the airflow through it is right. This furnace’s ECM motor has five speeds, and Conforto publishes the airflow of four of them: from 1,275 CFM on HIGH to 600 CFM on MED-LOW, depending on duct pressure. Our technicians can therefore set one speed for heating and another for cooling, instead of a compromise.

When the heat pump is heating, the five elements switch to backup. During defrost, the control turns on one or more elements depending on the DIP switch 3 setting. The coil can go on the supply or the return side.

Installed in the position that fits

The cabinet is 20 in wide by 21 in deep. Conforto allows three positions: upflow, downflow, with a non-combustible base mandatory on a combustible floor, or horizontal on the right side. Horizontal on the left side is not allowed, nor is placement on the front or back. On the electrical side, a 240 V single-phase circuit is needed with a 125 A minimum ampacity, a breaker of no more than 125 A and 2 AWG wire.

Our installation, from start to finish

  1. Free on-site estimate: possible position, ducts, electrical panel.
  2. Written quote, for the furnace alone or for the furnace with the heat pump.
  3. Installation of the KHE, duct connections, electrical hookup and a 1 or 2 stage thermostat, smart if you like.
  4. ECM speed settings and commissioning.

AirGreen is a family business established in Montreal for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work: the furnace, the coil and the hookup stay with the same team.

Let’s take the next step

We work in Montreal, Laval, Longueuil, the North Shore and the South Shore. Tell us whether you are after the furnace alone or a complete system, and we prepare the quote accordingly.

Ask for your free estimate and talk to us about your financing options for the furnace and the heat pump.

01 · What it is for

The indoor half of a complete central system

The KHE-02-G023-H3 heats with 23 kW of staged elements and moves air with a five-speed ECM motor. With a coil, it becomes the indoor unit of a central heat pump or air conditioner.

  • Converting central heating to a heat pump while keeping electric backup
  • Mechanical rooms or closets where the furnace must be downflow or horizontal
  • Homes that want adjustable airflow for heating and cooling
  • Replacing a tall furnace with an all-electric model
Five ECM speedsFrom 1,275 CFM on HIGH to 600 CFM on MED-LOW, depending on the speed and pressure published by Conforto.
Three positionsUpflow, downflow or horizontal right, in a 20 x 21 in cabinet.
Defrost backupWith a heat pump, one or more elements come on during defrost, depending on DIP switch 3.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerConforto
TypeElectric furnace with elements, multiposition Hiboy
PositionsUpflow, downflow or horizontal right
Output at 240 V23 kW (78,530 BTU/h)
Elements5 + 5 + 5 + 4 + 4 kW
First stage15 kW
Power supply240 V, 60 Hz, single phase
Element current92 A
Motor current3.9 A
Minimum circuit ampacity (MCA)125 A
Max. breaker125 A
Wire size2 AWG
MotorECM (Ecotech) 1/2 HP, 5 speeds
Blower wheel10 x 8 in
Airflow at 0.2 / 0.5 in. w.c.HIGH 1,275 / 1,200 · MED-HIGH 1,050 / 975 · MEDIUM 900 / 825 · MED-LOW 700 / 600 CFM
Heating speed (factory)HIGH at 0.5 in. w.c.
Max. outlet temperature194 °F (90 °C)
Max. matched cooling3.0 tons
Coil positionSupply or return (DIP switch 3)
Thermostat1 or 2 stage heating/cooling, 24 VAC (G, W1, W2, R, Y1, Y2, C), smart thermostat compatible
Supply opening (plenum)18 x 15 in
Return opening18 1/2 x 18 1/2 in (470 x 470 mm)
Filter1 disposable 20 x 20 x 1 in filter (supplied)
Dimensions (W x D)20 x 21 in (508 x 533 mm)
Shipping weight105 lb (48 kg)
Model numberKHE-02-G023-H3
03 · Before installing

What to know before installing

  • Sold alone: not eligible for the LogisVert grant. The furnace is not a heat pump.
  • Horizontal on the left side and installation on the front or back are not allowed by Conforto.
  • Downflow on a combustible floor: non-combustible base mandatory.
  • 240 V single-phase circuit: 125 A minimum ampacity, 125 A maximum breaker, 2 AWG wire.
  • Coil, outdoor unit and thermostat sold separately.
In the box
  • 1 disposable 20 x 20 x 1 in filter
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
CONFORTO
See all
06 · Questions

Frequently asked questions

What does the five-speed ECM motor allow?

Choosing an airflow suited to heating, then to the heat pump or air conditioner coil. Conforto publishes airflows from 1,275 CFM on HIGH to 600 CFM on MED-LOW, at 0.2 and 0.5 in. w.c.

Can it be installed horizontally?

Yes, on the right side only. It also installs upflow or downflow; horizontal on the left side and placement on the front or back are not allowed.

What role do the elements play with a heat pump?

They become the backup heat. During defrost, the control turns one or more of them on depending on the DIP switch 3 setting. The coil, up to 3.0 tons, goes on the supply or the return side.

What electrical hookup is needed?

A 240 V single-phase supply, a 125 A minimum circuit ampacity, a 125 A maximum breaker and 2 AWG wire, according to Conforto.

Does it qualify for a grant?

No. Sold alone, it does not qualify for the LogisVert grant. For a complete heat pump project, ask us for a quote.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

A 23 kW Conforto ECM Hiboy, installed by AirGreen