CONFORTO Lowboy KLE-02-G010-03 Electric Furnace | 10 kW - 240V
Conforto’s 10 kW Lowboy electric furnace: a low upflow cabinet, two 5 kW stages and a 3-speed PSC motor.
Model numberKLE-02-G010-03
514 316-2973 · sales@airgreen.ca
Quick facts
A 10 kW electric Lowboy whose every dimension you know before installation day
What it is, and who it suits
The Conforto KLE-02-G010-03 is an electric element furnace in the Lowboy format, the low version of the line, installed in upflow. It produces 10 kW, or 34,140 BTU/h at 240 V, in two 5 kW stages, and a 1/3 HP three-speed PSC motor distributes the warm air through the ducts.
It suits homeowners replacing an old Lowboy furnace first and foremost, where the ducts were laid out for that format: a bungalow in Laval, a semi-detached house on the North Shore, a unit in a plex. Its electrical needs are the lightest in the series, which often simplifies the connection to the existing panel.
Planning the space without surprises
Conforto publishes all three cabinet dimensions: 21 1/2 in wide, 44 in deep and 34 1/2 in high. The Lowboy therefore takes more floor space than a Hiboy, while staying low. Before ordering, we measure the location, the access and the service clearance required by the manual. The furnace weighs 110 lb (50 kg) shipped, a weight we plan for when handling it on the stairs.
The warm air plenum is 20 x 20 in and the return opening 18 1/2 x 18 1/2 in. Existing connections are adapted with transitions where needed, which we confirm on site.
With a heat pump, it becomes the backup heat
If you plan to add a central heat pump in a few years, this model lends itself to that: it accepts an air conditioner or heat pump coil of up to 3 tons, on the supply plenum or the return according to the DIP switch 3 setting. In heat pump mode, the elements take over in severe cold and during defrost. The QuietComfort function preheats recirculated air at low energy to smooth the step from one stage to the next.
A useful point: sold alone, the furnace is not a heat pump and does not qualify for the LogisVert grant.
What we do, from quote to commissioning
AirGreen is a family business established in Montreal for more than fifteen years, with RBQ licence 5645-9605-01 for ventilation, refrigeration and electrical work. We serve Montreal, Laval, Longueuil, the North Shore and the South Shore.
- Free estimate and measurement of the location, then a written quote
- Upflow installation and connection to the existing ductwork
- Dedicated 240 V circuit and thermostat hookup
- Motor speed setting, temperature rise check and installation of the supplied filter
Tell us about your basement and your cooling plans: the estimate is free, the quote is in writing, and AirGreen’s financing lets you spread the payments.
A 10 kW Lowboy to replace a low furnace
The KLE-02-G010-03 is an upflow Lowboy electric furnace: a low, deep cabinet that heats air in two 5 kW stages. Its 3-speed PSC motor distributes it through the existing ductwork.
- Basements where the ducts were laid out for a Lowboy furnace
- Replacing an old Lowboy furnace in a bungalow or a unit
- Homes that will add a central heat pump or an air conditioner of up to 3 tons
- Projects that need an electrical circuit limited to 60 A
Specifications
From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.
What to know before installing
- Upflow installation only: the manual rules out any other position for the Lowboy.
- Plan a 21 1/2 x 44 in footprint (W x D) and 34 1/2 in of height, plus the service clearance the manual requires.
- Dedicated 240 V, 60 Hz, single-phase circuit: 60 A minimum ampacity, breaker of no more than 60 A, 4 AWG wire.
- With a coil, DIP switch 3 is set according to its location (supply or return).
- Sold alone, the furnace is not a heat pump: it does not qualify for the LogisVert grant.
- 1 disposable 20 x 20 x 1 in filter
Manufacturer documents
Explore the range
Electric furnacesSee allSame brand
CONFORTOSee all
Frequently asked questions
How much space should be planned?
The cabinet is 21 1/2 in wide, 44 in deep and 34 1/2 in high. Add the service clearance required in Conforto’s manual: we measure it on site during the estimate.
Can it lie down or be installed in downflow?
No. Conforto states that the Lowboy installs in upflow only. For a horizontal or downflow installation, you need a KHE Hiboy furnace, which is multiposition.
What happens during heat pump defrost?
The furnace control turns on one or more electric elements during defrost, according to the DIP switch 3 setting.
Can a central humidifier be connected?
Yes. The furnace has a 24 VAC connection for accessories such as a central humidifier.
What breaker does it need?
A breaker of no more than 60 A on a 240 V single-phase circuit, with 4 AWG wire and a 60 A minimum circuit ampacity, according to Conforto.
A 10 kW Conforto Lowboy, installed by AirGreen
Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.
Specifications from the manufacturer’s documentation, checked on October 19, 2026.