01 · The ComfortMax simulator
CONFORTO furnace: which elements heat during a call for heat
Pick the output, the number of elements on at the start and the length of the call. The page applies the manual’s three thresholds, 13, 18 and 23 minutes, and plots each element over 30 minutes.
The simulator assumes a single-stage thermostat. That is the case the manual describes ComfortMax for; with a two-stage thermostat, the second-stage call (terminal W2) takes priority. The feature is turned on with the ComfortMax switch on the furnace. These rules come from the second-generation (-02) manuals; the two first-generation G010-H3 models come under another manual, which we have not re-read.
04 · Formats and motors in the shop
The 23 Hiboy and Lowboy furnaces, by output, format and motor
The code reads: KHE or KLE for the format, 02 or 01 for the generation, G020 for 20 kW, then the motor: -03 PSC 1/3 HP, -H3 ECM 1/2 HP, -05 PSC 3/4 HP and -H5 ECM 3/4 HP. A dash marks a combination the shop does not carry.
| Motor | Blower (in) | Outputs | Airflow at 0.2 in w.c. | Airflow at 0.5 in w.c. |
|---|
| PSC 1/3 HP | 10 × 8 | 10 to 23 kW | 1,100 cfm | 950 cfm |
| ECM 1/2 HP | 10 × 8 | 10 to 23 kW | 1,275 cfm | 1,200 cfm |
| PSC 3/4 HP | 12 × 10 | 27 kW | 1,775 cfm | 1,600 cfm |
| ECM 3/4 HP | 12 × 10 | 27 kW | 1,575 cfm | 1,475 cfm |
PSC or ECM: from 10 to 23 kW, the 1/2 HP ECM motor moves more air than the 1/3 HP PSC, 1,200 cfm against 950 at 0.5 in w.c. At 27 kW it is the other way round: 1,475 cfm for the 3/4 HP ECM, 1,600 for the 3/4 HP PSC. The airflow your ducts need is checked during the visit.
Maximum outlet air temperature: 194 °F (90 °C) on second-generation models (-02). The two first-generation G010-H3 models (-01) have their own values, on their product page.
Codes, motors, airflow and outlet temperature: KHE and KLE manuals, G2018 Rev. E, section 6.0 (airflow: p. 11 for the PSC, p. 12 for the ECM). Airflow on the HIGH speed tap, at 0.2 and 0.5 in of water column (w.c.) of external static pressure, the two columns both manuals print; the KLE manual also gives the ECM at 0.6 in, the KHE manual does not. Models: AirGreen shop, read live by this page.