AirGreenCONFORTO

AirGreen × CONFORTO · Furnaces · Hiboy and Lowboy · 23 models

KHE Hiboy or KLE Lowboy: two cabinets, the same ComfortMax control on second-generation models

Authorized CONFORTO dealer · sold and installed by AirGreen in Montreal, Laval, Longueuil and on the South and North Shores.

The whole CONFORTO space
  1. Home
  2. CONFORTO
  3. Furnaces
  4. Hiboy and Lowboy

CONFORTO · furnaces · KHE Hiboy and KLE Lowboy

CONFORTO Hiboy or Lowboy furnace: which elements heat, minute by minute

The CONFORTO element furnace comes in two cabinets: the KHE Hiboy, on a 20 × 21 in footprint, and the KLE Lowboy, 44 in deep. Pick an output and the length of a call for heat: the page shows which elements ComfortMax turns on, minute by minute, per the manual. Further down: the heat at 208 V and at 240 V, and both cabinets drawn to scale.

Updated October 29, 2026 · KHE and KLE manuals (G2018 Rev. E) and the CONFORTO Electric Furnaces brochure

KHE and KLE manuals · section 6.0

The elements of each output, in kW

10 kW
55
15 kW
555
18 kW
5454
20 kW
5555
23 kW
55544
27 kW
555444

Same layout in the Hiboy and the Lowboy. Block width is proportional to kW.

13 to 18 minthe call length ComfortMax aims for, per the manual
11 + 12KHE Hiboys and KLE Lowboys in the shop
21 / 44 indepth of the Hiboy and of the Lowboy
25,950 to 70,064BTU/h at 208 V, from the 10 kW to the 27 kW

This page answers

Hiboy or Lowboy, PSC or ECM: which one fits your home, and how does ComfortMax choose how many elements run?

The CONFORTO shop · Hiboy and Lowboy

All 23 element furnaces, right below

KHE Hiboy and KLE Lowboy, 10 to 27 kW, PSC or ECM motor. Priced by quote.

01 · The ComfortMax simulator

CONFORTO furnace: which elements heat during a call for heat

Pick the output, the number of elements on at the start and the length of the call. The page applies the manual’s three thresholds, 13, 18 and 23 minutes, and plots each element over 30 minutes.

Output

Elements on at the start

Length of the call for heat

20 kW · 15 min · 10 kW at the end of the call See the details

Source: CONFORTO KHE and KLE manuals, G2018 Rev. E (December 12, 2025), ComfortMax feature (13, 18 and 23-minute thresholds) and section 6.0 (kW of each element). The number of elements at the start comes from earlier calls; the page opens on each output’s first stage and turns the elements on in number order. Between 18 and 23 minutes, the page adds the element during the current call and changes nothing for the next one: our reading of the manual, which says an additional element is energized once the cycle runs past 18 minutes.

20 kW · 4 elements · 15-min call

10 kWon at the end of the call

0 minelements 1 and 2 · 10 kW
Call length15 min, inside the 13 to 18 min window
Next callno change per the manual
Heat, every element on68,288 BTU/h at 240 V · 51,890 BTU/h at 208 V

The simulator assumes a single-stage thermostat. That is the case the manual describes ComfortMax for; with a two-stage thermostat, the second-stage call (terminal W2) takes priority. The feature is turned on with the ComfortMax switch on the furnace. These rules come from the second-generation (-02) manuals; the two first-generation G010-H3 models come under another manual, which we have not re-read.

02 · At 240 V and 208 V

A CONFORTO furnace’s heat at 240 V and at 208 V, 10 to 27 kW

The kW in the model name are rated at 240 V. The manual also lists the heat at 208 V with every element on (W1 + W2): it is lower at every output.

10 kW

240 V34,140 BTU/h
208 V25,950 BTU/h

15 kW

240 V51,216 BTU/h
208 V38,925 BTU/h

18 kW

240 V61,460 BTU/h
208 V46,710 BTU/h

20 kW

240 V68,288 BTU/h
208 V51,890 BTU/h

23 kW

240 V78,530 BTU/h
208 V59,682 BTU/h

27 kW

240 V92,190 BTU/h
208 V70,064 BTU/h

KHE and KLE manuals, G2018 Rev. E: section 6.0 (240 V) and the 208 V output table, W1 + W2 total. Scale: 0 to 92,190 BTU/h.

03 · Hiboy or Lowboy

KHE Hiboy or KLE Lowboy at 20 kW: both cabinets to scale

At 20 kW, both formats have the same four 5 kW elements and the same electrical data. They differ in floor space, height, weight, openings and airflow direction.

Top view: floor space

Hiboy KHE20 × 21 inLowboy KLE21½ × 44 in12 in

Side view: depth and height

Hiboy KHE36 in21 inLowboy KLE34½ in44 in12 in

Hiboy format

KHE-02-G020 · 20 kW

Floor (width × depth)20 × 21 in
Height36 in
Shipping weight105 lb (48 kg)
Supply plenum15 × 18 in
Return plenum18½ × 18½ in
Airflowupflow, downflow or horizontal right
In the shop at 20 kW
or

Lowboy format

KLE-02-G020 · 20 kW

Floor (width × depth)21½ × 44 in
Height34½ in
Shipping weight110 lb (50 kg)
Supply plenum20 × 20 in
Return plenum18½ × 18½ in
Airflowupflow only
In the shop at 20 kW

KHE manual and KLE manual, G2018 Rev. E: dimensions, weight, plenums and installation positions. Both views share one scale; the bar is 12 in long.

04 · Formats and motors in the shop

The 23 Hiboy and Lowboy furnaces, by output, format and motor

The code reads: KHE or KLE for the format, 02 or 01 for the generation, G020 for 20 kW, then the motor: -03 PSC 1/3 HP, -H3 ECM 1/2 HP, -05 PSC 3/4 HP and -H5 ECM 3/4 HP. A dash marks a combination the shop does not carry.

MotorBlower (in)OutputsAirflow at 0.2 in w.c.Airflow at 0.5 in w.c.
PSC 1/3 HP10 × 810 to 23 kW1,100 cfm950 cfm
ECM 1/2 HP10 × 810 to 23 kW1,275 cfm1,200 cfm
PSC 3/4 HP12 × 1027 kW1,775 cfm1,600 cfm
ECM 3/4 HP12 × 1027 kW1,575 cfm1,475 cfm

PSC or ECM: from 10 to 23 kW, the 1/2 HP ECM motor moves more air than the 1/3 HP PSC, 1,200 cfm against 950 at 0.5 in w.c. At 27 kW it is the other way round: 1,475 cfm for the 3/4 HP ECM, 1,600 for the 3/4 HP PSC. The airflow your ducts need is checked during the visit.

Maximum outlet air temperature: 194 °F (90 °C) on second-generation models (-02). The two first-generation G010-H3 models (-01) have their own values, on their product page.

Codes, motors, airflow and outlet temperature: KHE and KLE manuals, G2018 Rev. E, section 6.0 (airflow: p. 11 for the PSC, p. 12 for the ECM). Airflow on the HIGH speed tap, at 0.2 and 0.5 in of water column (w.c.) of external static pressure, the two columns both manuals print; the KLE manual also gives the ECM at 0.6 in, the KHE manual does not. Models: AirGreen shop, read live by this page.

05 · Did you know

What the KHE and KLE manuals spell out

13 min

A call that ends too soon costs the next one an element

When the call for heat is satisfied in under 13 minutes, ComfortMax turns on one element fewer on the next cycle. Conversely, a call still running after 23 minutes turns every element on, and the next cycle starts with one more element.

KHE and KLE manuals, ComfortMax feature

70,064

At 208 V, the 27 kW gives less heat than the 23 kW at 240 V

The manual gives 70,064 BTU/h for the 27 kW at 208 V, against 78,530 BTU/h for the 23 kW at 240 V. In a building supplied at 208 V, the manual’s 208 V column is the one to read.

KHE and KLE manuals, section 6.0 and 208 V table

1 in

Above 20 kW, the supply duct needs 1 in of clearance

On the 23 kW and the 27 kW, the first 36 inches of supply duct need 1 in of clearance to combustibles. Past that point, the manual allows 0 in.

KHE and KLE manuals, clearances

06 · Questions

Your questions about CONFORTO Hiboy and Lowboy furnaces

Why doesn’t a CONFORTO furnace turn on all its elements?

With ComfortMax and a single-stage thermostat, that is by design. The control turns on only the elements it estimates are needed to satisfy the call within 13 to 18 minutes. If the call runs past 18 minutes, it adds one; after 23 minutes, it turns them all on. With a two-stage thermostat, the second-stage call takes priority.

KHE and KLE manuals, ComfortMax feature
How many elements does a CONFORTO furnace have?

Two to six, depending on output: 5 + 5 kW on the 10 kW, 5 + 5 + 5 kW on the 15 kW, 5 + 4 + 5 + 4 kW on the 18 kW, four 5 kW elements on the 20 kW, 5 + 5 + 5 + 4 + 4 kW on the 23 kW and 5 + 5 + 5 + 4 + 4 + 4 kW on the 27 kW. The layout is the same in the Hiboy and the Lowboy.

KHE and KLE manuals, section 6.0
Can the CONFORTO Lowboy furnace be installed horizontally?

No. The KLE manual allows the Lowboy in the upflow position only. For downflow or horizontal right, it takes the KHE Hiboy.

KHE and KLE manuals, installation positions
How much heat does a CONFORTO furnace give on 208 V?

Less than on 240 V. With every element on, the manual gives 25,950 BTU/h for the 10 kW and 70,064 BTU/h for the 27 kW; the 20 kW goes from 68,288 BTU/h at 240 V to 51,890 BTU/h at 208 V. The building’s voltage is noted during the in-home estimate.

KHE and KLE manuals, section 6.0 and 208 V table
What is QuietComfort on a CONFORTO furnace?

A feature the brochure presents as exclusive to CONFORTO. Turned on with DIP switch D, it cycles one element on and off at 4-minute intervals, for 3 hours at most, unless the thermostat calls for heat: the air circulating continuously is pre-warmed.

KHE and KLE manuals (DIP switch D); Electric Furnaces brochure, rev. 18/02/26
How much space does a CONFORTO Hiboy or Lowboy furnace need around it?

The cabinet is approved for zero clearance to combustible materials, whatever the output. The manual recommends 24 in (60 cm) of free space in front of the furnace for servicing.

KHE and KLE manuals; Electric Furnaces brochure, rev. 18/02/26
What does a CONFORTO Hiboy or Lowboy furnace cost?

Pricing is by quote. The in-home estimate is free, with no commitment.

AirGreen · Air conditioning & heating

Hiboy or Lowboy: we measure the space before the quote

During the visit, we measure the floor space and headroom, and note the building’s voltage and the airflow direction in your ducts. The quote follows.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Authorized CONFORTO dealerSold and installed by AirGreen
Free estimateAt home, no commitment
Showroom1370 Joliot-Curie St., Suite 712, Boucherville

Sources checked on October 28, 2026

  • CONFORTO KHE (Hiboy) electric furnace installation, operation and service manual, G2018 Rev. E, revised December 12, 2025: ComfortMax and QuietComfort features, section 6.0, 208 V table, airflow, dimensions and clearances (confortohvac.com).
  • CONFORTO KLE (Lowboy) electric furnace manual, G2018 Rev. E, revised December 12, 2025: the same sections, plus the upflow-only position (confortohvac.com).
  • CONFORTO “Electric Furnaces” brochure, rev. 18/02/26 (ComfortMax, QuietComfort, zero clearance): PDF.
  • AirGreen product pages (models, formats and motors in the shop), read live by this page.

The KHE and KLE manuals were re-read on October 29, 2026, after that check. Priced by quote; free in-home estimate.