CONFORTO Lowboy KLE-02-G020-H3 Electric Furnace | 20 kW - 240V

In stock

Conforto’s 20 kW Lowboy electric furnace with a five-speed 1/2 HP ECM motor, ready to take a heat pump or air conditioner coil.

Model numberKLE-02-G020-H3

20 kWheating at 240 V (68,288 BTU/h)
1,275 CFMHIGH speed at 0.2 in. w.c.
5 speeds1/2 HP ECM motor
240 V · single phaseECM motorUpflow only
Ask for a quote

514 316-2973 · sales@airgreen.ca

Quick facts

Model numberKLE-02-G020-H3
ManufacturerConforto
Output20 kW (68,288 BTU/h)
FormatLowboy, upflow
Power supply240 V, 60 Hz, 1 ph
MotorECM (Ecotech) 1/2 HP, 5 speeds
Max. cooling3.0 tons

A low-profile furnace ready for your future heat pump

An electric furnace designed for what comes next

You need to replace your basement furnace this winter, but you are already thinking about a central heat pump for next summer? The Conforto KLE-02-G020-H3 fits that two-step plan. It heats the house today with 20 kW of electric elements, in a 34 1/2 in high Lowboy format that sends air out through the top. The day the coil arrives, it is already equipped to receive it.

It is meant for families who want to do things in the right order: first reliable central heating, then air conditioning or a heat pump, without having to replace the furnace a second time.

The ECM motor pays off when a coil is added

A heat pump or air conditioner coil needs a precise airflow. That is where the 1/2 HP ECM (Ecotech) motor makes the difference: five speeds, and up to 1,275 CFM at 0.2 in. w.c. on HIGH. Conforto also publishes the airflow of the MED-HIGH, MEDIUM and MED-LOW speeds, so our technicians can pick the right speed for heating and for cooling, up to 3.0 tons.

The coil can go on the supply or the return side. A simple switch, DIP 3, tells the control where it is.

A Québec winter, with a heat pump and backup elements

When a central heat pump heats the house, the furnace does not disappear: its four 5 kW elements become the backup heat. During defrost cycles, the control turns one or more of them on so the rooms do not get cool air. Without a heat pump, it runs in two stages, with a 10 kW first stage.

It accepts a 1 or 2 stage 24 VAC thermostat, smart thermostats included, and a 24 VAC terminal powers an accessory such as a central humidifier. On the safety side, Conforto provides redundant high limits and over-voltage and under-voltage protection.

AirGreen’s installation, step by step

AirGreen is a family business established in Montreal for more than fifteen years. Our RBQ licence 5645-9605-01 covers ventilation, refrigeration and electrical work, the three trades this kind of project calls for.

  1. Free on-site estimate: electrical panel, basement space, condition of the ducts.
  2. Written quote, with or without the coil and outdoor unit, on your schedule.
  3. Furnace installed in upflow, connected to a circuit that meets Conforto’s requirements, thermostat wired.
  4. ECM speed setting and commissioning; if the heat pump comes later, we come back to adjust the settings for the coil.

Your project, at your pace

We work in Montreal, Laval, Longueuil, the North Shore and the South Shore. Tell us where you stand, urgent replacement or planned project, and we build the quote around it.

Book your free estimate and ask us about financing options for the furnace, or for the furnace and heat pump together.

01 · What it is for

A low-profile furnace that gets the house ready for a heat pump

The KLE-02-G020-H3 heats the house with four 5 kW elements. Its five-speed ECM motor adjusts the airflow to the coil you add, now or later, for a central heat pump or an air conditioner.

  • Replacing a basement Lowboy furnace while planning a central heat pump
  • Adding central air conditioning up to 3.0 tons on existing ductwork
  • Homes that want to keep electric backup heat behind the heat pump
  • Basements with low ceilings where warm air leaves through the top of the unit
Five ECM speedsUp to 1,275 CFM at 0.2 in. w.c. on HIGH, with three lower published speeds to match the airflow to the coil.
Backup and defrostWith a heat pump, the control turns on one or more elements during defrost, depending on the DIP switch 3 setting.
Coil where you need itConforto allows the coil on the supply or the return side, up to 3.0 tons of cooling.
02 · Specifications

Specifications

From the manufacturer’s documentation. A value the manufacturer does not publish is not listed.

ManufacturerConforto
TypeElectric furnace with elements, Lowboy (upflow)
Output at 240 V20 kW (68,288 BTU/h)
Elements5 + 5 + 5 + 5 kW
First stage10 kW
Power supply240 V, 60 Hz, single phase
Element current89 A
Minimum circuit ampacity (MCA)110 A
Max. breaker125 A
Wire size3 AWG
MotorECM (Ecotech) 1/2 HP, 5 speeds, 3.9 A
Blower wheel10 x 8 in
Airflow at 0.2 / 0.5 in. w.c.HIGH 1,275 / 1,200 · MED-HIGH 1,050 / 975 · MEDIUM 900 / 825 · MED-LOW 700 / 600 CFM
Heating speed (factory)HIGH at 0.5 in. w.c.
Max. outlet temperature194 °F (90 °C)
Max. matched cooling3.0 tons
Coil positionSupply or return (DIP switch 3)
Thermostat1 or 2 stage heating/cooling, 24 VAC (G, W1, W2, R, Y1, Y2, C), smart thermostat compatible
Supply opening (plenum)20 x 20 in (508 x 508 mm)
Return opening18 1/2 x 18 1/2 in (470 x 470 mm)
Filter1 disposable 20 x 20 x 1 in filter (supplied)
Dimensions (W x D x H)21 1/2 x 44 x 34 1/2 in (546 x 1,118 x 876 mm)
Shipping weight110 lb (50 kg)
Model numberKLE-02-G020-H3
03 · Before installing

What to know before installing

  • Sold alone: not eligible for the LogisVert grant. The furnace is not a heat pump.
  • Lowboy format: upflow installation only, according to Conforto.
  • 240 V, 60 Hz, single-phase power supply. Conforto lists a 110 A minimum circuit ampacity, a 125 A maximum breaker and 3 AWG wire.
  • The coil, the outdoor unit and the thermostat are chosen separately: they are not part of this product.
  • Footprint: 21 1/2 in wide, 44 in deep, 34 1/2 in high.
In the box
  • 1 disposable 20 x 20 x 1 in filter
04 · Documents

Manufacturer documents

05 · See also

Explore the range

Same category
Electric furnaces
See all
Same brand
CONFORTO
See all
06 · Questions

Frequently asked questions

Why choose the ECM motor version?

The 1/2 HP ECM motor has five speeds and moves up to 1,275 CFM at 0.2 in. w.c. That gives more room to set the airflow for a heat pump or air conditioner coil.

What do the elements do once a heat pump is installed?

They become the backup heat. During heat pump defrost, the control turns on one or more elements, depending on the DIP switch 3 setting.

Where does the coil go?

On the supply or the return side, your choice, according to Conforto. The maximum matched cooling capacity is 3.0 tons.

What electrical service does it need?

A 240 V single-phase supply, a 110 A minimum circuit ampacity, a 125 A maximum breaker and 3 AWG wire. We check your panel during the free estimate.

Does the furnace qualify for a grant?

No. Sold alone, it does not qualify for the LogisVert grant. If you add a heat pump, ask us for a quote on the whole project.

AirGreen · Montréal, Laval, Longueuil, South Shore, North Shore

Your 20 kW Conforto ECM Lowboy, installed by AirGreen

Tell us about your project: we check the sizing, confirm availability and send you a quote. Or let our technicians install it for you.

RBQ 5645-9605-01Ventilation, refrigeration and electrical
Free estimateon site, for any installation
Quote in 24 hby phone or email
Bouchervilleshowroom

Specifications from the manufacturer’s documentation, checked on October 19, 2026.