Electric heat only
You are replacing an electric furnace, or you heat without air conditioning. A KHE or KLE element furnace does the job, from 10 to 27 kW, in stages.
Hiboy and Lowboy, compared KHE and KLE manualsAirGreen × CONFORTO · Electric furnaces · 29 units
Two appliances for your ducts: the element furnace and the MHAH air handler
Authorized CONFORTO dealer · sold and installed by AirGreen in Montreal, Laval, Longueuil and on the South and North Shores.
CONFORTO · KHE and KLE furnaces · MHAH air handlers
Six outputs from 10 to 27 kW, Hiboy or Lowboy, with a PSC or ECM motor. Pick one: the page shows the first stage, the BTU/h, the total amps, the minimum circuit ampacity and the maximum breaker listed in the CONFORTO manual. The six MHAH air handlers of the central heat pump are here too.
Updated October 28, 2026 · KHE and KLE manuals, CONFORTO Electric Furnaces brochure and NEEP
KHE and KLE manuals · 240 V
The suggested maximum breaker, by output
A manufacturer suggestion, to be confirmed against local code.
This page answers
Element furnace or MHAH air handler: which one goes in your ducts, and what does it need from your electrical panel?
On this page
The CONFORTO shop · furnaces
KHE (Hiboy) and KLE (Lowboy) element furnaces, and MHAH air handlers. Priced by quote.
01 · The circuit, by output
Pick an output, a format and a motor: the figures come from the technical table in the KHE and KLE manuals. The manual gives the breaker and the wire size as suggestions to check against code.
Output
Format
Motor
KHE-02-G020-03 · 125 A · MCA 110 A See the details
Source: CONFORTO KHE and KLE manuals, G2018 Rev. E (December 12, 2025), section 6.0, Technical information, 240 V, single-phase, 60 Hz.
KHE-02-G020-03
125 Asuggested maximum breaker
What the tool does not do: it does not choose the output your home needs, it does not give the conductor size, and it does not replace a check of the electrical service. All three are settled on site, during the free estimate.
02 · Which appliance for your ducts
The 29 units in this collection do not all do the same job: start from what you have today.
You are replacing an electric furnace, or you heat without air conditioning. A KHE or KLE element furnace does the job, from 10 to 27 kW, in stages.
Hiboy and Lowboy, compared KHE and KLE manualsThe furnace accepts a coil of up to 3 tons (10 to 23 kW) or 5 tons (27 kW). The coil and the outdoor unit are not part of the CONFORTO range we offer; they are chosen during the in-home estimate.
See the circuit by output KHE and KLE manuals, section 6.0Here the MHAH air handler takes the furnace’s place. The indoor part of the MHSD heat pump, it houses the coil and blower in one cabinet, with no built-in heating element; back-up heat comes from an optional MHEAH module, 5 to 25 kW in our shop.
The central heat pumps The MHEAH modules CONFORTO central and ducted heat pump brochure, rev. 20/03/2025; AirGreen shop03 · Furnace or heat pump
The furnace figures come from its manual; the heat pump figures come from the NEEP list and from its AirGreen product page, which this page reads live.
Element furnace
Central heat pump
A furnace can also work with a heat pump on its own coil. A heat pump gives less heat as the cold deepens; an electric furnace’s output does not depend on the outdoor temperature. The KHE manual says the furnace control turns on one or more elements during a heat-pump defrost, and CONFORTO’s product page for the KLE Lowboy says it can run at the same time as a heat pump. The CONFORTO central heat pump, for its part, replaces the furnace with its MHAH. Only Hydro-Québec confirms the LogisVert amount granted.
Furnace: KHE manual, section 6.0 and defrost; CONFORTO’s KLE Lowboy product page. Heat pump: NEEP list (AHRI certificate 216683753) and the AirGreen product page, pulled live. LogisVert: participation guide, version 1.10 (September 15, 2026).
04 · The MHAH air handlers
In the shop, their title starts with “CONFORTO MHAH Electric Furnace”. They are air handlers (coil and blower in one cabinet), with no built-in heating element, paired with the MHSD outdoor unit of the same tonnage.
| Air handler | Tonnage | Max. airflow | Sound max. / min. | Size (W × D × H) |
|---|---|---|---|---|
| MHAH118DACFC | 1.5 tons | 576 cfm | 34 / 30 dB(A) | 21.02 × 17.52 × 45.00 in |
| MHAH124DACFC | 2 tons | 758 cfm | 39 / 33 dB(A) | 21.02 × 17.52 × 45.00 in |
| MHAH130DACFC | 2.5 tons | 894 cfm | 42 / 36.5 dB(A) | 21.02 × 21.02 × 49.02 in |
| MHAH136DACFC | 3 tons | 1,082 cfm | 45 / 41 dB(A) | 21.02 × 21.02 × 49.02 in |
| MHAH148DACFC | 4 tons | 1,282 cfm | 50 / 43.5 dB(A) | 21.02 × 21.02 × 49.02 in |
| MHAH160DACFC | 5 tons | 1,582 cfm | 51 / 41.5 dB(A) | 21.02 × 24.49 × 52.99 in |
CONFORTO makes MHEAH back-up modules from 3 to 25 kW; our shop carries 5 to 25 kW, sold separately: CONFORTO parts.
Airflow and size: AirGreen product records. Sound levels, coil and blower: CONFORTO central and ducted heat pump brochure, rev. 20/03/2025. MHEAH modules: MHAH installation manual QS002I and the AirGreen shop.
05 · Did you know
Canada
According to CONFORTO’s brochure, the KHE and KLE furnaces are made in Canada. CONFORTO covers their components for 5 years.
Electric Furnaces brochure, rev. 18/02/269 kW
On the 18 kW, the first stage is 9 kW: less than the 10 kW first stage of the 15 kW and the 20 kW.
KHE manual, G2018 Rev. E, section 6.020 × 20 × 1
The KHE Hiboy ships with a 20 × 20 × 1 in filter. The manual advises against pleated filters unless they are sized for the installation’s airflow.
KHE manual, G2018 Rev. E06 · Questions
The output is chosen on site: insulation, windows, storeys and ducts all count. During the free estimate we also look at the electrical service, because a 20 kW furnace alone needs a circuit with a minimum ampacity of 110 A.
KHE manual, section 6.0 (minimum circuit ampacity)The furnace circuit alone calls for a minimum ampacity of 60 A (10 kW) to 150 A (27 kW); from 18 kW it reaches 100 A. What your service can carry on top of the rest of the house is checked at your home.
KHE and KLE manuals, section 6.0Yes, with a coil of up to 3 tons (10 to 23 kW) or 5 tons (27 kW). For the KLE Lowboy, CONFORTO’s product page also allows the coil on the return side and running at the same time as the heat pump. The CONFORTO central heat pump in our shop installs with its own MHAH air handler, which replaces the furnace.
KHE and KLE manuals, section 6.0; CONFORTO KLE product pageThe PSC motor is 1/3 hp with 3 speeds (1.9 A), or 3/4 hp with 4 speeds (5.8 A) on the 27 kW. The ECM motor is 1/2 hp with 5 speeds (3.9 A), or 3/4 hp with 5 speeds (5.2 A) on the 27 kW. With the ECM, total amps rise by 2 to 3 A (except on the 27 kW: 114 A either way) and, from 10 to 23 kW, the temperature-rise range widens: on the 20 kW, 60 to 80 °F with the PSC and 50 to 80 °F with the ECM. The breaker and the minimum circuit ampacity stay the same. According to CONFORTO’s KLE Lowboy product page, the PSC motor is offered in Quebec only.
KHE manual, section 6.0; CONFORTO KLE product pageNo. It is the indoor unit of the MHSD central heat pump: coil and blower in one cabinet. It has no built-in heating element; an MHEAH module can be added as an option, 5 to 25 kW in our shop.
CONFORTO central and ducted heat pump brochure, rev. 20/03/2025; AirGreen shopCONFORTO covers the components of its KHE and KLE element furnaces for 5 years. Labour is not part of this manufacturer warranty.
Electric Furnaces brochure, rev. 18/02/26, and CONFORTO warranty cardThe KHE Hiboy takes 20 × 21 in of floor and stands 36 in high; it installs upflow, downflow or horizontal (right). The KLE Lowboy takes 21½ × 44 in and stands 34½ in high: barely lower, but twice as deep. The Hiboy and Lowboy page compares them in detail.
KHE and KLE manualsPricing is by quote. The in-home estimate is free, with no commitment.
AirGreen · Air conditioning & heating
We come and look at the furnace in place, the ducts and the electrical service, then give you a quote.
The LogisVert amount is indicative: only Hydro-Québec confirms the amount granted. Priced by quote; free in-home estimate.