AirGreenCONFORTO

AirGreen × CONFORTO · Electric furnaces · 29 units

Two appliances for your ducts: the element furnace and the MHAH air handler

Authorized CONFORTO dealer · sold and installed by AirGreen in Montreal, Laval, Longueuil and on the South and North Shores.

The whole CONFORTO space
  1. Home
  2. CONFORTO
  3. Electric furnaces

CONFORTO · KHE and KLE furnaces · MHAH air handlers

CONFORTO electric furnace: six outputs, and the circuit each one needs

Six outputs from 10 to 27 kW, Hiboy or Lowboy, with a PSC or ECM motor. Pick one: the page shows the first stage, the BTU/h, the total amps, the minimum circuit ampacity and the maximum breaker listed in the CONFORTO manual. The six MHAH air handlers of the central heat pump are here too.

Updated October 28, 2026 · KHE and KLE manuals, CONFORTO Electric Furnaces brochure and NEEP

KHE and KLE manuals · 240 V

The suggested maximum breaker, by output

10 kW34,140 BTU/h60 A
15 kW51,216 BTU/h90 A
18 kW61,460 BTU/h100 A
20 kW68,288 BTU/h125 A
23 kW78,530 BTU/h125 A
27 kW92,190 BTU/h150 A

A manufacturer suggestion, to be confirmed against local code.

10 to 27 kWsix outputs, 34,140 to 92,190 BTU/h at 240 V
60 to 150 Asuggested maximum breaker in the manual
3 or 5 tonsmaximum cooling coil, depending on output
23 + 6element furnaces and MHAH air handlers in the shop

This page answers

Element furnace or MHAH air handler: which one goes in your ducts, and what does it need from your electrical panel?

The CONFORTO shop · furnaces

All 29 units, right below

KHE (Hiboy) and KLE (Lowboy) element furnaces, and MHAH air handlers. Priced by quote.

01 · The circuit, by output

CONFORTO furnace breaker and amperage, 10 to 27 kW

Pick an output, a format and a motor: the figures come from the technical table in the KHE and KLE manuals. The manual gives the breaker and the wire size as suggestions to check against code.

Output

Format

Motor

KHE-02-G020-03 · 125 A · MCA 110 A See the details

Source: CONFORTO KHE and KLE manuals, G2018 Rev. E (December 12, 2025), section 6.0, Technical information, 240 V, single-phase, 60 Hz.

KHE-02-G020-03

20 kW · Hiboy · PSC motor

125 Asuggested maximum breaker

First stage10 kW, then 20 kW
Heat at 240 V68,288 BTU/h
Total amps91 A
Minimum circuit ampacity (MCA)110 A
Max. cooling coilup to 3 tons
Temperature rise60 to 80 °F (33 to 44 °C)

What the tool does not do: it does not choose the output your home needs, it does not give the conductor size, and it does not replace a check of the electrical service. All three are settled on site, during the free estimate.

02 · Which appliance for your ducts

Heat only, with air conditioning, or a central heat pump

The 29 units in this collection do not all do the same job: start from what you have today.

Electric heat only

You are replacing an electric furnace, or you heat without air conditioning. A KHE or KLE element furnace does the job, from 10 to 27 kW, in stages.

Hiboy and Lowboy, compared KHE and KLE manuals

Furnace plus air conditioning, or a heat pump

The furnace accepts a coil of up to 3 tons (10 to 23 kW) or 5 tons (27 kW). The coil and the outdoor unit are not part of the CONFORTO range we offer; they are chosen during the in-home estimate.

See the circuit by output KHE and KLE manuals, section 6.0

CONFORTO central heat pump

Here the MHAH air handler takes the furnace’s place. The indoor part of the MHSD heat pump, it houses the coil and blower in one cabinet, with no built-in heating element; back-up heat comes from an optional MHEAH module, 5 to 25 kW in our shop.

The central heat pumps The MHEAH modules CONFORTO central and ducted heat pump brochure, rev. 20/03/2025; AirGreen shop

03 · Furnace or heat pump

Around 50,000 BTU/h: a 15 kW furnace or a 5-ton heat pump

The furnace figures come from its manual; the heat pump figures come from the NEEP list and from its AirGreen product page, which this page reads live.

Element furnace

15 kW · KHE or KLE

Heat at 240 V51,216 BTU/h
Outdoor temperatureno effect
Minimum circuit ampacity85 A
Suggested maximum breaker90 A
or

Central heat pump

5 tons · MHSD160 + MHAH160

Heat at −15 °C (NEEP)48,500 BTU/h
Heat at −30 °C (NEEP)29,900 BTU/h
Minimum circuit ampacity, outdoor unit42 A
Plus the MHAH and back-up moduleextra amperage, set by the module
LogisVert, indicative amount$5,040
See the 5-ton MHSD

A furnace can also work with a heat pump on its own coil. A heat pump gives less heat as the cold deepens; an electric furnace’s output does not depend on the outdoor temperature. The KHE manual says the furnace control turns on one or more elements during a heat-pump defrost, and CONFORTO’s product page for the KLE Lowboy says it can run at the same time as a heat pump. The CONFORTO central heat pump, for its part, replaces the furnace with its MHAH. Only Hydro-Québec confirms the LogisVert amount granted.

Furnace: KHE manual, section 6.0 and defrost; CONFORTO’s KLE Lowboy product page. Heat pump: NEEP list (AHRI certificate 216683753) and the AirGreen product page, pulled live. LogisVert: participation guide, version 1.10 (September 15, 2026).

04 · The MHAH air handlers

The central heat pump’s indoor unit, 1.5 to 5 tons

In the shop, their title starts with “CONFORTO MHAH Electric Furnace”. They are air handlers (coil and blower in one cabinet), with no built-in heating element, paired with the MHSD outdoor unit of the same tonnage.

Air handlerTonnageMax. airflowSound max. / min.Size (W × D × H)
MHAH118DACFC1.5 tons576 cfm34 / 30 dB(A)21.02 × 17.52 × 45.00 in
MHAH124DACFC2 tons758 cfm39 / 33 dB(A)21.02 × 17.52 × 45.00 in
MHAH130DACFC2.5 tons894 cfm42 / 36.5 dB(A)21.02 × 21.02 × 49.02 in
MHAH136DACFC3 tons1,082 cfm45 / 41 dB(A)21.02 × 21.02 × 49.02 in
MHAH148DACFC4 tons1,282 cfm50 / 43.5 dB(A)21.02 × 21.02 × 49.02 in
MHAH160DACFC5 tons1,582 cfm51 / 41.5 dB(A)21.02 × 24.49 × 52.99 in

CONFORTO makes MHEAH back-up modules from 3 to 25 kW; our shop carries 5 to 25 kW, sold separately: CONFORTO parts.

Airflow and size: AirGreen product records. Sound levels, coil and blower: CONFORTO central and ducted heat pump brochure, rev. 20/03/2025. MHEAH modules: MHAH installation manual QS002I and the AirGreen shop.

05 · Did you know

Three details from CONFORTO’s own documents

Canada

Made in Canada

According to CONFORTO’s brochure, the KHE and KLE furnaces are made in Canada. CONFORTO covers their components for 5 years.

Electric Furnaces brochure, rev. 18/02/26

9 kW

The 18 kW’s first stage

On the 18 kW, the first stage is 9 kW: less than the 10 kW first stage of the 15 kW and the 20 kW.

KHE manual, G2018 Rev. E, section 6.0

20 × 20 × 1

The filter comes with it

The KHE Hiboy ships with a 20 × 20 × 1 in filter. The manual advises against pleated filters unless they are sized for the installation’s airflow.

KHE manual, G2018 Rev. E

06 · Questions

Your questions about CONFORTO furnaces

What CONFORTO furnace output does my home need?

The output is chosen on site: insulation, windows, storeys and ducts all count. During the free estimate we also look at the electrical service, because a 20 kW furnace alone needs a circuit with a minimum ampacity of 110 A.

KHE manual, section 6.0 (minimum circuit ampacity)
Is a 100 A electrical service enough for a CONFORTO furnace?

The furnace circuit alone calls for a minimum ampacity of 60 A (10 kW) to 150 A (27 kW); from 18 kW it reaches 100 A. What your service can carry on top of the rest of the house is checked at your home.

KHE and KLE manuals, section 6.0
Can a heat pump be added to a CONFORTO furnace?

Yes, with a coil of up to 3 tons (10 to 23 kW) or 5 tons (27 kW). For the KLE Lowboy, CONFORTO’s product page also allows the coil on the return side and running at the same time as the heat pump. The CONFORTO central heat pump in our shop installs with its own MHAH air handler, which replaces the furnace.

KHE and KLE manuals, section 6.0; CONFORTO KLE product page
PSC or ECM: what changes on a CONFORTO furnace?

The PSC motor is 1/3 hp with 3 speeds (1.9 A), or 3/4 hp with 4 speeds (5.8 A) on the 27 kW. The ECM motor is 1/2 hp with 5 speeds (3.9 A), or 3/4 hp with 5 speeds (5.2 A) on the 27 kW. With the ECM, total amps rise by 2 to 3 A (except on the 27 kW: 114 A either way) and, from 10 to 23 kW, the temperature-rise range widens: on the 20 kW, 60 to 80 °F with the PSC and 50 to 80 °F with the ECM. The breaker and the minimum circuit ampacity stay the same. According to CONFORTO’s KLE Lowboy product page, the PSC motor is offered in Quebec only.

KHE manual, section 6.0; CONFORTO KLE product page
Is a CONFORTO MHAH air handler a furnace?

No. It is the indoor unit of the MHSD central heat pump: coil and blower in one cabinet. It has no built-in heating element; an MHEAH module can be added as an option, 5 to 25 kW in our shop.

CONFORTO central and ducted heat pump brochure, rev. 20/03/2025; AirGreen shop
What warranty does CONFORTO give on its furnaces?

CONFORTO covers the components of its KHE and KLE element furnaces for 5 years. Labour is not part of this manufacturer warranty.

Electric Furnaces brochure, rev. 18/02/26, and CONFORTO warranty card
CONFORTO Hiboy or Lowboy furnace: which one?

The KHE Hiboy takes 20 × 21 in of floor and stands 36 in high; it installs upflow, downflow or horizontal (right). The KLE Lowboy takes 21½ × 44 in and stands 34½ in high: barely lower, but twice as deep. The Hiboy and Lowboy page compares them in detail.

KHE and KLE manuals
What does a CONFORTO furnace cost?

Pricing is by quote. The in-home estimate is free, with no commitment.

AirGreen · Air conditioning & heating

Your CONFORTO furnace, chosen with your panel in mind

We come and look at the furnace in place, the ducts and the electrical service, then give you a quote.

RBQ 5645-9605-01Subclasses 15.8, 15.10 and 16
Authorized CONFORTO dealerSold and installed by AirGreen
Free estimateAt home, no commitment
Showroom1370 Joliot-Curie St., Suite 712, Boucherville

Sources checked on October 28, 2026

  • CONFORTO KHE (Hiboy) electric furnace installation, operation and service manual, G2018 Rev. E, revised December 12, 2025: section 6.0 and defrost operation (confortohvac.com).
  • CONFORTO KLE (Lowboy) electric furnace manual, G2018 Rev. E, revised December 12, 2025, section 6.0 (confortohvac.com).
  • CONFORTO “Electric Furnaces” brochure, rev. 18/02/26: PDF.
  • CONFORTO electric furnace warranty card (July 2015): 5 years on components.
  • CONFORTO central and ducted heat pump brochure, rev. 20/03/2025: PDF.
  • CONFORTO KLE Lowboy furnace product page (running with a heat pump, coil on the return side, PSC motor in Quebec), confortohvac.com, read October 28, 2026.
  • MHAH air handler installation manual QS002I (MHEAH modules, 3 to 25 kW).
  • NEEP cold-climate heat pump list, AHRI certificate 216683753 (MHSD160 + MHAH160), read October 28, 2026.
  • Hydro-Québec, LogisVert participation guide, residential, version 1.10 (September 15, 2026).
  • AirGreen product records (MHAH airflow and size), read October 28, 2026.

The LogisVert amount is indicative: only Hydro-Québec confirms the amount granted. Priced by quote; free in-home estimate.